Sec. 113-145. Separation of water and sanitary sewer lines.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
There shall be no physical connection between a drinking water supply line and a sewer or appurtenance.
(1) Horizontal separation. Water lines shall be laid at least ten feet horizontally from a sewer or a sewer manhole whenever possible; the distance shall be measured outside edge-to-outside edge.
When local conditions prevent a horizontal separation of ten feet, the water line may be laid closer to a sewer or sewer
manhole provided that:
a. The bottom (invert) of the water main shall be at least 18 inches above the top (crown) of the sewer.
Where this vertical separation cannot be obtained, the sewer shall be constructed of ductile iron pipe and
pressure tested in place without leakage prior to backfilling.
(2) Vertical separation. The water line shall be laid in separate trenches or on an undisturbed earth shelf. Where possible the water main shall pass over the sewer main with a vertical separation of at least 18 inches. When local conditions prevent a vertical separation of 18 inches between the bottom of the water main and the top of the sewer the following construction standards shall be used:
a. The sewer shall be constructed of ductile iron pipe and pressure tested in place without leakage prior to backfilling.
b. Adequate structural support for both the water and sewer mains shall be provided to prevent settling and excessive deflection of the joints.
c. That length of sewer main shall be centered at the point of the crossing such that the joints shall be equidistant from the point of crossing.
d. No deflection of the joints is permitted within ten feet of the point of crossing.
Historia
(Ord. No. 2009-06-18, (12.5), 6-29-2009)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.