A. General. The final plat shall be clearly and legibly drawn on Mylar, vellum or paper sheets. The scale of the final plat shall not exceed I in. = 100 ft. The plat shall not exceed 36 in. X 48 in. If the complete plat cannot be shown on one sheet, several sheets with an index map indicated on each sheet shall be used. In no case shall sheet size be less than 8-1/2 in. X 11 in.

The final plat shall conform to the preliminary plat and it may constitute only that portion of the approved preliminary plat which the sub-divider proposes to record and develop at any time, provided that such portion conforms to the staging established on the preliminary plat procedure and to the requirements of these rules and regulations.

The final plat shall contain the following information:

I. Names of the subdivision and streets.

2. Property address numbers furnished by City of Kennesaw Community Development Department

3. Reference to recorded subdivision plats of adjoining land by record name.

4. Date of plat drawing, graphic scale, and magnetic north point.

5. Gross acreage of tract, square footage of out parcel.

6. Location of tract (land lot and district).

7. Former name of subdivision, if any or all of the final plat has been previously subdivided.

8. Vicinity map at a scale of I" = 2000'.

9. Index map on each sheet when more than one sheet is required.

10. Courses and distances to the nearest existing street, intersections, or other recognized permanent monuments or bcnchmarkers.

11. Exact boundary lines of the tract, to be indicated by a heavy line, giving distances to the nearest I/IO-foot and angles to the nearest second, which shall be balanced and closed. The error of closure shall not exceed I: 10,000. The error of closure shall be stated. The tract boundaries shall be determined by accurate survey in the field.

12. Land Lot lines shall be accurately tied to lines of the subdivision by angles and distances when such lines traverse the subdivision; when the subdivision does not intersect a land lot line, the lines of a major controlling street shall be projected and tied to a land lot line by angles and distance. In both cases, the measured distance from land lot tie to a respective land lot corner shall be shown with the magnetic bearing of the land lot line. No approximate land lot lines shall be shown on the subdivision plat.

13. Exact locations, widths, and names of all streets, alleys, and sidewalks within and immediately adjoining the plat and the exact locations and widths of all sidewalks.

14. Street centerlines showing angles of deflection and standard curve data of intersection, radii, length of tangents and arcs, and degree of curvature with basis of curve data, design speeds, horizontal and vertical site distances.

15. Lot lines with dimensions to the nearest 1/10-foot, necessary internal angles, arcs and chords and tangent or radii of rounded corners.

16. Building setback lines with dimension.

17. Lots or sites numbered in numerical and clockwise order. Blocks shall be identified alphabetically.

18. Cultural features, including cemeteries and historic features.

19. Property/lease lines clearly delineated.

20. References to recorded and unrecorded access/cross parking, easements, utilities, and off-site stormwater management facility.

21. Location, dimensions, drainage areas, and purposes of all drainage structures, stormwater management structures, access easements, and any other easements, including slope easements, tributary and state mandated buffers and corridors, flood hazard areas and elevations, new or existing water and sewer easements with setback requirements that are or shall be maintained by the Water System, and any areas to be reserved, donated, or dedicated to public use or sites for other than residential use with notes stating their purpose and limitations; and of any areas to be reserved by deed covenant for common uses of all property owners. Delineation of protected wetlands with total acreage noted.

22. For purposes of dedication of stormwater management easements and facilities, reference should be made to the Cobb County Comprehensive Stormwater Management Quantity and Quality Ordinance.

23. Accurate locations, materials, and descriptions of monuments and markers. Monuments to be placed after final street improvements shall be designated as "future".

24. Seal of appropriate design professional.

25. Zoning stipulations and variances (if any) and the date approved by the City Council.

26. State law prohibits the private construction, planting, or otherwise making improvements on the dedicated public right-of-way. The sole responsibility for repairing of any damage of any such improvement shall be the property owners.

27. Tabular chart which specifies the length of each public street or right-of-way.

28. Signature line for approvals from all applicable departments and Mayor and City Council.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:kennesaw/zoning/10.03.10@2026-11-11-675f4c8149

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.