LaFayette · Ordenanza de zonificación
Appendix A - ZONING § 29-36 / Article VI - SUPPLEMENTAL REGULATIONS AND MODIFICATIONS
Section 29-65. Building materials and design requirements.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Multiple-Family Dwellings. The following provisions govern the use of building materials and design requirements for all new constructions, and repairs to damages of fifty (50) percent or more, of multi-family dwellings within R-3 and B-2 Districts.
Exterior façade materials: Exterior building materials for all sides visible from a street shall be composed of:
(1) A combination of at least thirty (30) percent brick masonry, stone masonry, brick veneer, or stone veneer, and seventy (70) percent fiber cement siding, or Premium Vinyl Siding (minimum thickness .044 mils) for each side; or
(2) Architectural designs with combinations of three (3) exterior materials such as brick, stone masonry and fiber cement siding, or Premium Vinyl Siding (minimum thickness .044 mils) in minimum percentages of thirty
(30) percent for each side.
Horizontal patterned fiber cement siding must be in the upper section of the structure. Architectural accent siding is allowable but must also be placed in the upper section of the structure.
Architectural treatments shall be consistent on all sides of the building.
Permitted materials shall be brick, stone, brick veneer, stone veneer, vinyl siding and soffit with a minimum thickness of .044 mils, natural wood, or cement-based material siding having the appearance of wood, such as Hardi-Plank/Board.
Prohibited materials: Generally metal siding, vinyl siding and soffit with a thickness of less than .044 mils, smoothfaced concrete block, split-face block masonry, textured concrete units, fiber cement, stucco, tilt-up concrete panels, prefabricated steel panels, standing-seam or corrugated metal walls, including aluminum, sheet metal or any other metal substance, standard concrete block, Masonite, T111 and all other forms of plywood, chipboard and particle board are all prohibited as external finish materials.
Exceptions: Vinyl siding, split face block masonry or textured concrete units are allowable on any side not visible from a street. Split face block masonry is allowable at ground level up to four (4) blocks high on any side not visible from the street.
Façade articulation: Buildings designed with completely flat façades and monotone color schemes are not permitted.
All buildings are required to have horizontal and vertical façade variations such as pop-outs, bays, recesses, arches, banding, columns, gables, porches, or projections, or similar features and modulation to break up roof lines. Such features are required at least every twenty (20) feet along all exterior wall planes and shall be of sufficient width and depth to clearly differentiate each feature from those next to and around. All exterior walls facing a public street or parking area should be articulated by a change in material or depth of material as described above. Fenestration (the design and disposition of windows and other exterior openings) should also be utilized to enhance the articulation in the design. The building official shall have discretion to authorize small adjustments to the distance between roof line variation in circumstances where he/she deems it necessary for the design to meet the intent of the design standards.
Roof materials: All roof surfaces exposed to view shall be covered with asphalt or fiberglass shingles, wood shakes or shingles, clay tiles, slate or standing seam metal, or corrugated metal, excluding used or rusty material without approval by Council.
Pitched roofs: All structures shall have a minimum roof pitch of 5:12.
Flat roofs: No flat roofs are permitted.
Throughout subsection 29-65(a), when reference is made to sides of a dwelling that are "visible from a street," the applicable sides of the dwelling are defined as follows:
(1) If the dwelling is located on a corner lot that is bordered by two (2) or more streets, then all four (4) sides of the dwelling;
(2) If the dwelling is not located on a corner lot that is bordered by two (2) or more streets, then the applicable sides of the dwelling are the side that faces the street and the two (2) sides of the dwelling that are adjacent to the side of the dwelling that faces the front of the street. The fourth side of the dwelling is not considered to be applicable or visible from the street.
(b) Commercial buildings. The following provisions govern the use of building materials and design requirements for all new constructions, repairs to damages of fifty (50) percent or more, of commercial buildings within B-1 and B-2 Districts.
Exterior façade materials: Exterior building materials for all sides visible from a street shall be composed of:
(1) A combination of at least thirty (30) percent brick masonry, stone masonry, split face block masonry or textured concrete units and seventy (70) percent fiber cement siding for each side provided, however, that the thirty (30) percent material requirement may be cumulative for all sides so long as all visible sides from the street have at least eight (8) inches from the finished grade of brick masonry, stone masonry, brick veneer, or stone veneer; or
(2) Architectural designs with combinations of three
(3) exterior materials such as brick, stone masonry, split face block masonry, textured concrete units and fiber cement siding shall in minimum percentages of thirty (30) percent for each side.
Horizontal patterned fiber cement siding must be in the upper section of the structure. Architectural accent siding is allowable but must also be placed in the upper section of the structure.
Architectural treatments shall be consistent on all sides of the building.
EIFS systems are not preferred but are permitted provided it consists of no more than thirty (30) percent of each exterior side and is installed in the upper half of the structure.
Façade Articulation: Buildings designed with completely flat façades and monotone color schemes are not permitted.
All buildings are required to have horizontal and vertical façade variations such as pop-outs, bays, recesses, arches, banding, columns, or similar features and modulation such to break up roof lines. Such features are required at least every thirty (30) feet along all exterior wall planes and shall be of sufficient width and depth to clearly differentiate each feature from those next to and around. All exterior walls facing a public street or parking area should be articulated by a change in material or depth of material and by fenestration (the design and disposition of windows and other exterior openings). Building elements such as canopies, porches, bays or projections should be used to break up the appearance of a long wall. The building official shall have discretion to authorize small adjustments to the distance between roof line variation in circumstances where he/she deems it necessary for the design to meet the intent of the design standards.
Prohibited Materials: Metal siding, vinyl siding, smooth-faced concrete block, stucco, tilt-up concrete panels, prefabricated steel panels, standing-seam or corrugated metal walls, including aluminum, sheet metal or any other metal substance, standard concrete block, Masonite, T111 and all other forms of plywood, chipboard and particle board are all prohibited as external finish materials. Also, vinyl siding and soffit less than .046 thickness.
Roof materials: All roof surfaces exposed to view shall be covered with asphalt or fiberglass shingles, wood shakes or shingles, clay tiles, slate or standing seam metal, or corrugated metal, excluding used or rusty material without approval by Council.
Pitched Roofs: All structures shall have a minimum roof pitch of 6:12.
Flat Roofs: No flat roofs are permitted without façade and roof design sufficient enough to create modulation and screening of HVAC other types of equipment that are non-architectural treatments.
Throughout subsection 29-65(b), when reference is made to sides of a building that are "visible from a street," the applicable sides of the building are defined as follows:
(1) If the building is located on a corner lot that is bordered by two (2) or more streets, then all four (4) sides of the building; or
(2) If the building is not located on a corner lot that is bordered by two (2) or more streets, then the applicable sides of the building are the side that faces the street and the two (2) sides of the building that are adjacent to the side of the building that faces the front of the street. The fourth side of the building is not considered to be applicable or visible from the street.
(c) Single-Family Dwellings. The following provisions govern the use of building materials and design requirements for all new construction, and repairs to damages of fifty (50) percent or more, of single-family dwellings within all zoning districts:
(1) All framing materials utilized in the construction of single-family dwellings must be grade #2 lumber or better:
(2) All floor systems must use sixteen-inch centers, twentythree and thirty-two hundredths (23.32) inches four (4) feet by eight (8) feet T&G subfloors, and must be attached with adhesive and screws or adhesive and ring shank nails.
(3) All wall framing must meet the following requirements:
(i) Single bottom plate;
(ii) Double top plate;
(iii) Sixteen-inch centers;
(iv) Studs must be nailed twice through bottom plates and twice through top plates;
(v) Sealant must be placed under bottom plates:
(vi) Two (2) by six (6) or greater walls when drain lines/vents above two inches in diameter penetrate top plate, including dryer vents;
(vii) Blocking in all exterior walls above nine (9) feet in height; and
(viii) A minimum of seven-sixteenth-inch sheathing which must be fastened at sill plate, rim joist, and bottom of plate wall, and must run from sill plate top of the ceiling joist.
(4) For house wraps, approved house wrap must be used on entire home or zip system, provided that house wrap seams must be taped and zip tape must be rolled.
(5) All roof framing must meet the following requirements:
(i) Rafters must be sixteen (16) inches on centers and trusses must be based on engineer design;
(ii) Decking must be seven-sixteenth (7/16) inches;
(iii) Two (2) by six (6) sub-fascia; and (iv) Soffit must be a minimum of twelve (12) inches except on pyramid hip, mansard, or gambrel roofs.
(6) All electrical conductors size 4 gauge and below, must use solid copper, or stranded copper wiring, provided, however, that copper clad aluminum is not permissible.
(7) All siding must meet the following requirements:
(i) All vinyl must be four-tenths (.040) minimum; and (ii) Masonry, including stucco, must be utilized on all sides facing roads.
(8) All roofing must meet the following requirements:
(i) Felt must be utilized with a drip edge required all the way around the roof and ice and water barriers must be installed where necessary;
(ii) Shingles may be utilized provided, however, that three-tab shingles are prohibited; and
(iii) Metal roofs must have dome cap screws and must have lx minimum furring strops over roof decking, under metal.
(9) All windows must be taped to house wrap with appropriate tape that is lapped properly.
(10) Exterior doors must utilize rot free jambs if the door is exposed but such jambs are not required if the door is under cover.
(11) For single-family dwellings located within subdivisions, the following additional provisions are applicable:
(i) Exterior façade materials: Horizontal patterned fiber cement siding, or premium vinyl siding must be in the upper section of the structure. Architectural accent siding is allowable but must also be placed in the upper section of the structure. Approved masonry must be beneath other permitted materials but is allowable as a material up to one hundred
(100) percent of surface area. Architectural treatments shall be consistent on all sides of the building. Permitted materials shall be brick, stone, brick veneer, stone veneer, vinyl siding and soffit with a minimum thickness of forty-four hundredths (.044) mils, natural wood, or cement-based material siding having the appearance of wood, such as Hardi-Plank/ Board. In addition, exterior building materials for all sides visible from a street shall be composed of:
(A) A combination of at least thirty (30) percent brick masonry, stone masonry, brick veneer, or stone veneer, and seventy (70) percent fiber cement siding, or premium vinyl siding
(minimum thickness .044 mils) for each side, provided, however, that the thirty (30) percent material requirement may be cumulative for
all sides so long as all visible sides from the street have at least eight (8) inches from the finished grade of brick masonry, stone masonry, brick veneer, or stone veneer.
(B) Architectural designs with combinations of three (3) exterior materials such as brick,
stone masonry and fiber cement siding, or Premium Vinyl Siding (minimum thickness forty-four hundredths (.044) mils) in minimum percentages of thirty percent (30%) for each side.
(12) Prohibited Materials: Generally metal siding, vinyl siding, and soffit with a thickness of less than forty-four hundredths (.044) mils, smooth-faced concrete block, split-face block masonry, textured concrete units, stucco, tilt-up concrete panels, prefabricated steel panels, standing-seam or corrugated metal walls, including aluminum, sheet metal or any other metal substance, standard concrete block, Masonite, Tl 11 and all other forms of plywood and particle board are all prohibited as external finish materials. Notwithstanding the foregoing, vinyl siding, split face block masonry or textured concrete units are allowable on any side not visible from a street, and split face block masonry is allowable at ground level up to four (4) blocks high on any side not visible from the street.
(i) Façade Articulation: Buildings designed with completely flat façades and monotone color schemes are not permitted. All buildings are required to have horizontal and vertical façade variations such as pop-outs, bays, recesses, arches, banding, columns, gables, porches, or projections or similar features and modulation to break up roof lines. Such features are required at least every thirty (30) feet along all exterior wall planes and rooflines and shall be of sufficient width and depth to clearly differentiate each feature from those next to and around. All exterior walls facing a public street or parking area should be articulated by a change in material or depth of material as described above. Fenestration (the design and disposition of windows and other exterior openings) should also be utilized to enhance the articulation in the design. The Building official shall have discretion to authorize small adjustments to the distance between roof line variation in circumstances where he/she deems it necessary for the design to meet the intent of the design standards.
(ii) Roof materials: All roof surfaces exposed to view shall be covered with asphalt or fiberglass shingles, wood shakes or shingles, clay tiles, slate or metal.
Metal roofs are permitted only if they have a reflectance similar to (or less than) that of the siding material.
(iii) Pitched Roofs: All structures shall have a minimum roof pitch of 6:12 on main roof. Dormers, and other secondary roofs must be approved by building official.
(iv) Throughout this Section, when reference is made to sides of a dwelling that are "visible from a street," the applicable sides of the dwelling are defined as follows:
(A) If the dwelling is located on a corner lot that is bordered by two (2) or more streets, then all four (4) sides of the dwelling; and
(B) If the dwelling is not located on a corner lot that is bordered by two (2) or more streets, then the applicable sides of the dwelling are the side that faces the street and the two (2) sides of the dwelling that are adjacent to the side of the dwelling that faces the front of the street. The fourth side of the dwelling is not considered to be applicable or visible from the street.
(Ord. No. 18-08, § 2, 5-14-2018; Ord. No. 19-05, § 1, 5-13-2019;
Ord. No. 24/01, § 2, 7-8-2024; Ord. No. 24/08, § 1, 11-11-2024;
Ord. No. 25/03, §§ 2, 3, 3-10-2025)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.