LaGrange · Ordenanza de zonificación
Title 25B - LAND USE AND ZONING / Chapter 25B-20 - CIVIC DESIGN
Sec. 25B-20-6. Outdoor lighting.
Sobre este texto
- As published by Municode, retrieved 2026-11-14
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
- Tables are shown as their rows, with the cells separated by a bar ( | ).
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Purpose. The regulations of this section are intended to:
(1) Permit reasonable uses of outdoor lighting for nighttime safety, utility, security, productivity, enjoyment and commerce;
(2) Curtail and reverse the degradation of the nighttime visual environment and the night sky;
(3) Preserve the dark night sky for astronomy;
(4) Minimize glare, obtrusive light and artificial sky glow by limiting outdoor lighting that is misdirected, excessive or unnecessary;
(5) Conserve energy and resources to the greatest extent possible; and
(6) Help protect the natural environment from the damaging effects of night lighting from human-made sources.
(b) General regulations. Outdoor lighting fixtures shall be located, aimed or shielded to minimize glare and stray light trespassing across lot lines and into the public right-of-way.
| | | |----|----| | At Property Lines Including Rights-of-Way | Maximum Footcandles | | At property line abutting a residential or an agricultural use | 0.5 | | At property line abutting an office or institutional use | 1.0 | | At property line abutting all other uses | 1.5 |
- Off-Street Parking Lots | Minimum Footcandles | Average Footcandles | Maximum Footcandles
- Agricultural uses | None | None | 4.0
- Residential uses | 0.5 | 2.0—3.0 | 4.0
- Office-professional uses | 1.0 | 3.0—4.0 | 6.0
- Industrial uses | 1.0 | 4.0—5.0 | 8.0
- All other uses | 2.0 | 6.0—7.0 | 12.0
(c) Parking areas. All lighting fixtures servicing parking lots must be directed downward and not towards buildings or other areas.
(d) Specific lighting regulations in the DT-MX district.
(1) The following are expressly prohibited:
a. Aerial lasers;
b. Searchlight-style lights;
c. Light sources that exceed two hundred thousand (200,000) lumens or intensity in any direction of two million (2,000,000) candelas or more;
d. Mercury vapor lamps;
e. Low-sodium vapor lamps;
f. LED light strips.
(2) The following luminaries and lighting systems are expressly exempt from the regulations of this division:
a. Underwater lighting used for the illumination of swimming pools and fountains;
b. Temporary holiday lighting;
c. Lighting required and regulated by the Federal Aviation Administration, or other authorized federal, state or local government agency;
d. Emergency lighting used by police, fire, or medical personnel, or at their direction;
e. All outdoor light fixtures producing light directly from the combustion of fossil fuels, such as kerosene and gasoline; and
f. Security lighting controlled and activated by a motion sensor device for a duration of ten (10) minutes or less.
Historia
(Ord. No. 21-10, § 1, 6-22-21)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.