In addition to the development standards contained in article 4 of these regulations, the following standards are required within R-4 districts:
(a) Minimum floor area per dwelling unit (for residential) or for buildings (for
nonresidential): Eight hundred (800) square feet.
(b) Minimum lot area:
(1) Unsewered areas without public water: Not allowed; however, a lot of record lawfully zoned R4 existing at the time of passage of these regulations may nevertheless be developed for a single-family dwelling only if
approved by the Lamar County Health Department.
(2) Sewered areas: With or without jointly-owned common areas: Ten thousand eight hundred ninety (10,890) square feet; however, a lot of record lawfully existing at the time of passage of these regulations may nevertheless be developed with a use which is permitted within a R-4 district if approved by the Lamar County Health Department.
(3) Unsewered areas with public water:
Not allowed; however, a lot of record lawfully zoned R4 existing at the time of passage of these regulations may nevertheless be developed with a use which is permitted within an R-4 district only if approved by the Lamar County Health Department.
(c) Minimum lot width:
(1) Unsewered areas: One hundred fifty
(150) feet.
(2) Sewered areas: Sixty (60) feet.
(d) Minimum front yard:
(1) Arterial streets/roads: Seventy-five
(75) feet from the property line.
(2) Collector streets and other streets/ roads: Forty (40) feet from the
property line.
(e) Minimum side yard: Total for both side yards of at least twenty (20) feet, with the minimum for either side of five (5)
feet. A fire wall is required for side yards of ten (10) feet or less. A side lot adjoining a differently zoned district must be at least twenty (20) feet.
(f) Minimum rear yard: Five (5) feet. A fire wall is required for rear yards of ten (10) feet or less. If rear lot line adjoins a differently zoned district, minimum
required yard is forty (40) feet, regardless of the type of dwelling unit on the lot.
(g) Maximum lot coverage by impervious surfaces: Forty (40) percent.
(h)—(x) Development standards common to most districts are listed under subsections 505(h)—(x).
(y) Fire walls: All side and rear walls of attached dwelling units which are less
than ten (10) feet from the lot line must be fire walls. (See Georgia Building Code for construction standards.)