Lee County · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 38 - LAND DEVELOPMENT CODE / Article III - LAND DEVELOPMENT PERMITS / Division 3 - CONSTRUCTION PLAN STANDARD AND SPECIFICATIONS
Sec. 38-134. Plan and profile of sanitary sewer.
Sobre este texto
- As published by Municode, current through 2026-06-23
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Plan view shall show the following:
(1) Label and show all existing contours at a maximum two-foot interval;
(2) Label and show all proposed contours at a maximum one-foot interval;
(3) All grade work to be shown by contours or grade slope indicators;
(4) Road pavement and/or curb and gutter edges;
(5) Right-of-way limits;
(6) Easements, minimum building front and rear setbacks, if applicable;
(7) If crossing is made with storm sewer system then show detail construction information about storm system such as inverts, pipe size, grade, type of pipe, number of inlets, amount of rip-rap (length and width dimensions);
(8) If crossing water lines and structures show elevations of such;
(9) Sewer lines, structures, alignment and related information such as elevations, grades, pipe size and type, inverts, stations of structures, etc.
(10) Station numbers; and
(11) Stations display at least at 100-foot intervals.
(b) Profile view shall show the following:
(1) Existing contour elevations;
(2) Sewer line information;
(3) Station numbers;
(4) Base elevations;
(5) Any pipe crossings;
(6) Stations display at 100-foot intervals; and
(7) Transition locations.
Historia
(Ord. of 9-18-00(2), § 38-134)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.