Sec. 38-328. Curbs.

Sobre este texto

  • As published by Municode, current through 2026-06-23
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) Street parking.

(1) If vertical curbs are used then an additional eight feet of pavement shall be required when on-street parking is planned.

(2) If mountable or roll type curbs are used eight feet of shoulder space at a one-half-inch per foot slope shall be required when on-street parking is planned.

(3) If open ditch road sections are used then ten feet of shoulder at a one-half-inch per foot slope shall be required when on-street parking is planned.

(b) Types of curbs.

(1) Vertical curb and gutter sections: Eighteen-inch gutter with a six-inch wide by six-inch high curb (total 24-inch width).

(2) Mountable curb section: Twelve-inch gutter with a 12-inch wide by four-inch high curb (total 24-inch width).

(3) Header curb section: Twelve-inch below pavement by six-inch above pavement by six-inch wide (total six-inch width).

(4) Valley gutter section: Twenty-four-inch wide with a center depression of three-inch (total 24-inch width).

(c) Construction of curbs shall meet the following standards:

(1) When required curbs and gutters shall be placed along edges of all street pavements and shall be formed to the cross section shown on the plans. Whenever practical, the curb and gutters shall be constructed using slip-form or extrusion equipment.

(2) Constructed of Portland cement, air-entrained concrete, class B, 3,000 psi.

(3) Weakened plane joints, straight and at regular intervals not to exceed ten feet. Where curb and gutter is adjacent to concrete pavement the weakened plane joints shall be aligned with the pavement joints where practical.

(4) Expansion joints shall be provided meeting the following requirements:

a. Expansion material shall be one-half-inch premolded;

b. Spaced at a maximum interval not to exceed 100 linear feet;

c. All joints shall be installed vertical and perpendicular to the line of the curb;

d. The joint filler shall not protrude above the finished surface of the concrete;

e. No expansion joints shall be constructed in access ramps or driveways;

f. Expansion material is required at any point where new curb and gutter abuts any other concrete structure; and

g. A five-foot long transition shall be provided between normal gutter and pitched gutter unless otherwise noted on construction plans.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 9-18-2000(2), § 38-328)