(a) Sanitary sewers shall be sized to ensure that estimates of quantities of wastewater flows based upon present and future populations, along with projected infiltration and inflow do not exceed pipe capacity.
(b) In no case shall pipe less than eight inches in diameter be allowed for collector or interceptor lines. Special consideration shall be given to the pipe diameter if commercial and industrial customers are anticipated to contribute to the system.
(c) Pipe material may be ductile iron, cast iron or polyvinylchloride (PVC).
(1) Ductile iron.
a. Ductile iron pipe and fittings can be used as specified for gravity sewers. The minimum wall thickness shall be as specified in ASTM A746 for thickness class
52. Extra thickness shall be provided where required by deep cover in accordance with ASTM A746, table 12, for type 2 laying conditions.
b. Ductile iron pipe for gravity sewers shall be mechanical joint or push on joint, unless specified otherwise, conforming to ANSI/AWWA C151/A21.51. Pipe and fittings shall have a cement mortar lining conforming to ANSI/AWWA C104/ A21.4. A standard bituminous coating shall be applied to the exterior of all ductile iron pipe fittings.
c. Ductile iron lock joint shall meet the requirements of ANSI/AWWA C151/A21.51 for ductile iron pipe and may be of the bolted type suitable for 150 psi working pressure. If bolted type pipe is used, all bolts shall be corten steel.
d. Ductile iron fittings shall be designed for a pressure rating of 250 psi and shall be in accordance with ANSI/AWWA C110/A21.10. Fittings shall be mechanical joint.
(2) Cast iron.
a. Cast iron pipe shall be mechanical joint conforming to federal specifications WW-P-421c. Fitting shall be class 150 or its equivalent, for the mechanical joint pipe or slip on joints, if approved by the manager of development services.
b. Cast iron pipe in general, shall be used at wet crossings and at points specifically designated on the plans, including force mains.
(3) Polyvinylchloride (PVC).
a. Plastic gravity sewer pipe and fittings shall be unplasticized PVC meeting or exceeding ASTM D3034, classification SDR 35, for smooth wall pipe, or ASTM F794 for ribbed sewer pipe. Ribbed pipe shall be homogeneous and have a smooth interior with a solid cross sectional rib exterior. Exterior ribs shall be open profile and perpendicular to the axis of the pipe to allow placement of the sealing gasket.
b. Pipe lengths shall not exceed 20 feet and provisions shall be made at each joint to accommodate expansion and contraction.
c. All pipe and fittings shall be joined by means of integral wall bell and spigot and sealed with a rubber gasket. This joint shall be capable of withstanding an internal hydrostatic pressure of 25 psi for one hour with no leakage.
d. When using PVC pipe, metalized locating tape shall be placed 18 to 24 inches below the ground surface.