(a) Instrument cleaning.
(1) All non single-use, non-disposable instruments shall be properly cleaned and sterilized after each use by following the manufacturer's recommendations prior to packaging and sterilization.
(2) Employees shall wear heavy-duty, multi-use, waterproof gloves while cleaning instruments.
(3) Used instruments shall be soaked in an EPA approved disinfectant until cleaning can be performed. The solution shall be changed as recommended by the solution manufacturer.
(4) Instruments shall be disassembled for cleaning.
(5) All instrument components shall be cleaned, either manually or in an ultrasonic cleaner, using the appropriate cleaning agent specific to the type of cleaning performed.
(b) Instrument packaging.
(1) Employees shall wear clean gloves while packaging or wrapping instruments.
(2) Instruments shall be wrapped or packaged with a sterilizer indicator on each package.
(3) All packages shall be labeled with the time and date of sterilization.
Packages will no longer be considered sterile six months after the date of sterilization.
(c) Instrument sterilization.
(1) The sterilizer shall be designed and labeled as a medical instrument sterilizer.
(2) The operator's manual for the sterilizer shall be available on the premises, and the sterilizer shall be operated
according to the manufacturer's recommendations.
(3) The sterilizer shall be cleaned and maintained according to the manufacturer's recommendations.
(4) A sterilizer load log shall be maintained for the studio and made available for inspection by properly identified representatives of the board of health during normal operation hours. The log shall be kept for a minimum of one year. The log shall contain the following documentation for each load:
a. Description of instruments contained in the load;
b. Date of sterilization, and time if more than one load is processed in a single day;
c. Sterilizer cycle time and temperature;
d. Indication of proper sterilization of instruments, as indicated by the appropriate color change of the sterilizer indicator on each package. The indicator used shall be compatible with the sterilization process being used; and
e. Action taken when appropriate color indicator change did not occur.
(d) Sterilization monitoring.
(1) Sterilizer monitoring shall be performed at least once every two months (unless more frequent monitoring is specified by the manufacturer) by using a commercial biological monitoring (spore) system.
(2) All biological indicators shall be analyzed by a laboratory that operates under FDA guidelines and is independent of the studio with reports
sent to the studio and the Gwinnett County Board of Health Environmental Health Section.
(3) Biological indicator test results shall be maintained on the premises for a
minimum of one year and must be available for inspection by properly identified representatives of the board of health during normal operation hours.
(4) Upon notification of a positive microbiological monitoring report, the sterilizer shall be immediately checked for proper use and function. The studio will cease operations immediately upon receipt of a positive microbiological report. Three consecutive biological tests shall be
performed before the studio is reopened. All three tests must be negative. The studio shall have the option to purchase and install a new sterilizer in order to reopen prior to the receipt of the test results on the previous sterilizer.
(e) Instrument storage.
(1) Hands shall be washed and gloved prior to handling sterilized instruments.
(2) After sterilization, the instruments shall be stored in a dry, clean area
reserved for storage of sterilized instruments.
(f) Single-use items. If the body art studio operates using only pre-sterilized instruments and supplies, a sterilizer is not required.