Ir al contenido
Georgia Commons
Menú

Lilburn · Ordenanza de zonificación

Lilburn Zoning Ordinance

Este documento se muestra completo, como un solo texto: su fuente no lo divide en secciones.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
  • Read by OCR from a scanned page: a character, a name, or a number may be misread.

Este texto se leyó por OCR de una página escaneada: una letra, un nombre o un número pueden estar mal leídos.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

Parte 6 de 7. Este texto es largo, así que su página lo muestra en partes, en el orden de la fuente. Un enlace a uno de sus párrafos lleva a la parte que lo contiene.

is obtained in individual servings, at 135°F (57°C) or above in facilities meeting the requirements of this article, and is served directly in the unopened container in which it was packaged.

5. Home prepared foods or condiments are prohibited from service, use and/or sales in temporary food service units.

(e) Equipment and Supplies Required.

1. Indicating thermometers for immersion into food or cooking media shall be of metal stem type construction, numerically scaled,

and accurate to ±2 degrees Fahrenheit.

2. Enough potable water shall be available at the event for consumption and in the establishment for food preparation, cleaning, and sanitizing utensils and equipment, and for handwashing.

3. Ice shall be handled as follows:

(i) Ice that is consumed or that contacts food shall be made under conditions meeting the requirements of this chapter, (ii) The ice shall be obtained only in chipped, crushed, or cubed form and in single-use safe plastic or wet strength paper bags filled and sealed at the point of manufacture,

(iii) The ice shall be held in these bags until it is dispensed in a way that protects it from contamination, and (iv) Storage of packaged or wrapped food in contact with water or undrained ice is prohibited.

4. Temporary food service operations shall provide only individually wrapped single-service articles for use by the consumer.

5. A hearing facility capable of producing enough hot water shall be provided on the premises.

6. Equipment shall be located and installed in a way that prevents food contamination and that also facilitates cleaning the establishment.

7. Food-contact surfaces of equipment shall be protected from contamination by consumers and other contaminating agents. Effective shields for such equipment shall be provided, as necessary, to prevent contamination.

8. Facilities for cleaning and sanitizing utensils and equipment shall be provided at the temporary site or permitted base of operation. Such items shall be

cleaned and sanitized at least daily or more often if prescribed by the health authority.

9. When food is prepared on the site, a system capable of producing enough hot water for cleaning and sanitizing utensils and equipment shall be provided on the premises.

10. A convenient handwashing facility shall be available for employee handwashing. This facility shall consist of, at least, warm running water, soap, and individual paper towels.

(f) Liquid Waste. All sewage including liquid waste shall be disposed of as specified under Rule .06 subsections (4)(h) and (i).

(g) Construction.

1. Floors within food preparation and display areas shall be constructed of concrete, asphalt, tight wood, or other similar material

kept in good repair and clean.

2. Doors to food preparation areas shall be solid or screened and shall be self-closing or as otherwise approved by the health authority.

3. Screening material used for walls, doors, or windows shall be at least 16 mesh to the inch.

4. Air curtains shall be properly designed and installed, and approved by the health authority.

5. Ceilings shall be made of wood or other material that protects the interior of the establishment from the weather.

6. Walls and ceilings of food preparation areas shall be constructed in a way that prevents the entrance of insects.

(h) Protection from Contamination.

1. Approved means of excluding insect and vermin from food preparation, service areas and from waste storage areas must be provided commensurate with the type and scope of food service permitted.

2. Counter-service openings shall not be larger than necessary for the particular operation conducted.

3. These openings shall be provided with effective means to restrict the entrance of flying insects.

4. Counter-service openings shall be kept closed when not in actual use, except that these openings may remain open if air curtains are provided as deemed adequate by the health authority.

5. All food preparation and food display areas shall be adequately protected from dust, contamination by patrons, and from insects by provision of walls, ceilings,

shields, screens or other approved barriers or devices.

6. Open, unprotected display or service of food is prohibited.

(i) Exceptions to Compliance. Temporary food services which:

1. Are sponsored by a political subdivision of this state or by an organization exempt from taxes

under paragraph (1) of subsection of (a) of Code Section 48-7-25 or under Internal Revenue Code

Section 501(d) or paragraphs (1) through (8) or paragraph (10) of Section 501 (c) of the Internal Revenue Code, as that code is defined in Code Section 48-1-2;

2. Last 120 hours or less; and

3. When sponsored by such an organization, is authorized to be conducted pursuant of a permit issued by the municipality or county in which it is conducted.

Authority O.C.G.A. 26-2-373, 31-2-4. Administrative History. Original Rule entitled "Inspection of Premises" was filed and effective on July 19,1965 as 270-5-6-.06.

Amended: Rule repealed and a new Rule entitled "Transportation" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.08. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Construction and Maintenance of Physical Facilities" adopted. Filed July 10, 1986; effective July 30, 1986.

Amended: Rule repealed and a new Rule of the same title adopted. Filed July 11, 1995; effective July 31, 1995. Amended: Rule repealed and a new Rule entitled "Special Food Service Operations" adopted. Filed Jan.

26, 2006; effective Feb. 15, 2006. Amended: Rule repealed and a new Rule of same title adopted. Filed Jan.

24, 2007; effective Feb. 13, 2007. Amended: Rule repealed and a new Rule of same title adopted. Filed August 23, 2007; effective Sept. 12, 2007.

290-5-14-.09. Certification and Standardization of Environmental Health Personnel.

(1) Responsibilities and Requirements. All Environmental Health personnel who are assigned responsibilities in food service plan review, permitting, inspecting or other means of enforcing this chapter, will successfully complete:

(a) Nationally Recognized Food Safety Training Program. A nationally recogAPPENDIX C—BOARD OF HEALTH RULES 290-5-14-.09 nized food safety training program

approved by the department and a professionally validated examination that is accredited by the Conference for Food Protection, prior to acquiring food service program responsibilities;

(b) Standardization. Standardization in food safety inspection techniques, obtained through a program approved by the department, within two years

of acquiring food service program responsibilities; and

(c) Food Safety Related CEU Credit. Eight hours of food safety related CEU credit every two years.

(2) Record of Training, Standardization and CEU Credit. A record of training, standardization and CEU credit for Environmental Health personnel shall be maintained in the

office where each Environmental Health employee works.

(3) Time Frame. All Environmental Health personnel currently having responsibilities enforcing this chapter when it is adopted, must obtain the credentials as specified in subsection (1)(a) and (b) of this Rule within two years of implementation of this chapter.

Authority O.C.G.A. §§ 26-2-373, 31-2-4. Administrative History. Original Rule entitled "Routine Inspection" was filed and effective on July 19,1965 as 270-5- 6-.09. Amended: Rule repealed and a new Rule entitled "Poisonous and Toxic Materials" adopted. Filed January 24, 1967; effective February 12, 1967. Amended:

Rule renumbered as 290-5-14-.09. Filed June 10, 1980;

effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Special Food Service Operation"

adopted. Filed July 10, 1986; effective July 30, 1986.

Amended: Rule repealed and a new Rule of the same title adopted. Filed July 11, 1995; effective July 31, 1995. Amended: Rule repealed and a new Rule entitled "Certification and Standardization of Environmental Health Personnel" adopted. Filed Jan. 26, 2006; effective Feb. 15, 2006. Amended: Rule repealed and a new Rule of same title adopted. Filed Jan. 24, 2007; effective Feb. 13, 2007.

290-5-14-.10. Compliance Procedures.

(1) Permits.

(a) Issuance. Permits shall be designed and issued by the health authority.

Such permits shall be valid, within the date range specified on the permit, until suspended or revoked.

(b) Suspension or Revocation. The health authority shall have the power and authority to suspend or revoke permits for failure to comply with the provisions of this chapter.

1. When an application for a permit is denied or the permit previously granted is to be suspended or revoked, the applicant or holder

thereof shall be afforded notice and hearing as provided in O.C.G.A. § 31-5, Article 1.

2. If an application is denied or a permit is suspended or revoked, the applicant or holder of the permit must be notified in writing, specifically stating any and all reasons why the action was

taken.

3. The purpose of these procedures is to state the minimum actions to be taken to fulfill the obligation of the health authority in assuring compliance with the regulations when the continued operation of a restaurant presents a substantial and imminent health

hazard to the public or when a food service establishment is in flagrant or continuing violation of this chapter.

4. Suspension is effective upon service of a written notice thereof, and food service must cease immediately.

5. The notice must state the basis for the suspension and advise the permit holder of the right to a preliminary hearing on request within 72 business hours of the health authority.

6. If requested, the preliminary hearing will be held by an experienced supervisory level employee of the health authority not directly involved in the suspension.

7. The rules of evidence will not apply, but both the health authority and the permit holder may present witnesses, records and

argument.

8. The hearing official will be authorized immediately to rescind or modify the suspension or to continue the suspension with or without conditions.

9. If the suspension is not rescinded, the permit holder will have the right on request to an evidentiary hearing. If a hearing is not requested, upon correction of all violations, owner may request an

inspection to reinstate permit.

(c) Notice of Hearing. For the purpose of this chapter a notice of hearing is properly served when delivered in person or by registered or certified mail.

(d) Conditions Warranting Action. The health authority may summarily suspend a permit to operate a food service establishment if it determines through inspection, or examination of

employees, food, records, or other means as specified in this chapter, that an imminent health hazard exists.

(e) Resumption of Operations. If operations of a food service establishment are discontinued due to the existence

of an imminent health hazard or otherwise according to law, the permit holder shall obtain approval from the

health authority before resuming operations.

(2) Inspections.

(a) Risk Categorization. Inspections of a food service establishment shall be conducted based on risk categorization. The risk type shall be determined by the menu items served, the food preparation processes performed,

and the previous food safety history in the food service establishment. Each establishment shall be grouped in one of the following categories:

1. Risk Type I. Frequency of inspection will be one time per year for establishments that do not cook

any foods. This includes establishments that may reheat commercially precooked ingredients or foods such as hotdogs and sausages;

2. Risk Type II. Frequency of inspection will be two times per year for establishments that cook and/or

hold and reheat foods that are prepared onsite; or

3. Risk Type III. Frequency of inspection will be three times per year for establishments that have

a required and approved HACCP plan. One of these inspections will be a scheduled inspection to meet with the Certified Food Safety Manager.

(b) Inspection Frequency.

1. The health authority may conduct one or more construction/ preoperational inspections to verify that the food service establishment is constructed and

equipped in accordance with the approved plans and approved modifications of those plans, and is in compliance with law and this chapter.

2. An initial inspection will be conducted in an establishment prior to the food permit being issued.

3. The first routine inspection will be conducted within 60 days following the opening of the establishment.

4. After the first routine inspection, establishments maintaining an "A" food safety grade shall be inspected based on the risk categorization specified in subsection (2)(a)1.—3. of this Rule.

5. Establishments that receive a "C" or "U" food safety grade will have at least one additional routine inspection added in a twelvemonth period, and may have more inspections at the discretion of

the health authority.

6. An establishment that maintains an "A" food safety rating on three consecutive routine inspections may have the frequency of routine inspections reduced to one time per year for Risk Type II

establishments and reduced to two times per year for Risk Type III establishments at the health authority's discretion.

7. The reduced inspection frequency may continue until the food service establishment incurs a grade of a "B", "C" or "U". The routine

inspection frequency will then resume to the number specified for Risk Type, but may be more frequent as deemed necessary for the enforcement of this chapter

by the health authority.

(c) Follow-up Inspections. Follow-up inspections may be conducted at anytime at the discretion of the health authority, but must be conducted within

ten days after an establishment receives a grade "U".

(d) Access.

1. Representatives of the health authority, after proper identification, shall be permitted to enter any food service establishment or

operation at any reasonable time for the purpose of making inspections and review of pertinent records to determine compliance with this chapter. Should access

be denied, an inspection warrant may be obtained as authorized in O.C.G.A. § 31-5, Article 2.

2. If a person denies access to the health authority, the health authority shall:

(i) Inform the person that:

(I) The permit holder is required to allow access to the health authority,

(II) Access is a condition of the acceptance and retention of a food service establishment permit to operate, and

(IV) If access is denied, an inspection warrant, issued by the appropriate authority to order access, may be obtained according to law; and (ii) Make a final request for access.

(e) Inspection of Mobile Food Service Units. When inspecting a mobile food service unit in a county other than the county of origin, the health authority will contact the health authority in the county of origin to find out the violations received during the last inspection of the base of operation. These violations will be noted as violations

during the inspection of each mobile unit.

(f) Report of Inspection.

1. The health authority shall document on the department's current approved "Food Service Establishment Inspection Report" form and "Food Service Inspection Report Addendum" form(s):

(i) Administrative information about the food service establishment's legal identity, street and mailing addresses,

type of establishment and operation, inspection date, and other information which may include such information as type of water supply and sewage disposal, status

of the permit, and personnel certificates that may be required;

(ii) Specific factual observations of violations or other deviations from this chapter that require correction by the permit holder including:

(I) Failure of the person in charge to demonstrate the knowledge of foodborne illness prevention, application of HACCP principles, and the requirements of this chapter as specified under Rule .03 subsections (1)(a)—(c).

(II) Failure of food employees, conditional employees, and the person in charge to report a disease or medical condition as specified under Rule .03 subsections

(4)(b) and (d),

(III) Nonconformance with Risk Factor and Public Health Intervention provisions of this chapter,

(IV) Failure of the appropriate food employees to demonstrate their knowledge of, and ability to perform in accordance with, the procedural, monitoring, verification, and corrective action practices required by the health authority for a variance or HACCP Plan,

(V) Failure of the person in charge to provide records required by the health authority for determining conformance with a HACCP plan as specified under Rule .02 subsection (5)(d),

(VI) Nonconformance with critical limits of a HACCP plan; and (iii) The numerical score and equivalent grade, based on debiting the appropriate points for violations and repeat violations of code provisions found or observed during the inspection.

2. Upon the completion of the inspection, the evaluating official shall have the person in charge

sign the inspection report form.

The person in charge's signature shall not necessarily indicate agreement with the findings noted on the inspection.

3. The health authority shall:

(i) Inform a person who declines to sign an acknowledgment of receipt of inspectional findings that:

(I) An acknowledgment of receipt is not an agreement with findings,

(II) Refusal to sign an acknowledgment of receipt will not affect the permit holder's obligation to correct the violations noted in the inspection report within the time frames specified, and

(III) A refusal to sign an acknowledgment of receipt is noted in the inspection report and conveyed

to the health authority's historical record for the food service establishment; and (ii) Make a final request that the person in charge sign an acknowledgment receipt of inspectional findings.

(g) Displaying of the Inspection Report.

1. The most current inspection report shall be prominently displayed in public view at all times, within 15 feet of the front or

primary public door and between five feet and seven feet from the floor and in an area where it can be read at a distance of one foot away.

2. Food service establishments with drive-thru windows will post the current inspection report specified under 1. of this subsection, and also have the inspection report posted so that a minimum of the top one-third of a copy of the

current inspection report is visible through each window allowing customers to easily read the score, date of inspection and establishment information.

3. At food service establishments with no primary or public door, the current inspection report shall be prominently displayed at all times where the documents can be read by the public from a distance of one foot away. If requirements of this paragraph are not possible because of physical restrictions, a location will be determined as approved by the health authority.

4. The food service establishment inspection report addendum(s), completed by the health authority during an inspection, will not be required to be displayed, but

will be made available by the food service establishment to the public upon request.

(h) Violation Categories.

1. Violations of this chapter are categorized according to their potential for creating a health risk to the consumer. All violations shall

be recorded on the current inspection report and addendum(s). Violations are divided into two categories, Risk Factors/Public Health Interventions (RF/PHI)

Categories and Good Retail Practices (GRP) Categories.

2. Violation of Risk Factors/Public Health Interventions (RF/PHI) categories are prominent on the inspection report because maintaining these items in compliance is vital to preventing foodborne illness. These items are

numbered 1 to 9 on the inspection report and divided into Subcategory "1" and "2" as follows:

(i) Subcategory "1" items cover provisions of the code, that when applied, would directly prevent, eliminate or reduce hazards to a safe level to protect consumer health. Because the probability of occurrence and severity of a hazard is greater when these

provisions are out of compliance, the incidence and impact of foodborne illness is increased and therefore a

point value is assigned for a violation of any subcategory "1" item of nine points, and (ii) Subcategory "2" items cover provisions of the code, that when applied, would indirectly prevent, eliminate or reduce hazards to a safe level

to protect consumer health.

Because the probability of occurrence and severity of a hazard is lower than subcategory "1" when these provisions are out of compliance, the incidence and impact of

foodborne illness is not as great and therefore a point value is assigned for a violation of any subcategory "2" item of four points.

3. Risk Factors and Public Health Interventions (RF/PHI) Categories include:

(i) Supervision.

(ii) Employee health, good hygienic practices, preventing contamination by hands.

(iii) Approved source.

(iv) Protection from contamination.

(v) Cooking of potentially hazardous foods, consumer advisory.

(vi) Holding of potentially hazardous foods, datemarking of potentially hazardous foods.

(vii) Highly susceptible populations.

(viii) Chemicals.

(ix) Conformance with approved procedures.

4. Good Retail Practices (GRP) categories are deemed to be operational and maintenance violations that, if not corrected, increase the potential for causing

food borne illness. A violation of an item in a GRP category constitutes a one to three point deduction from the overall score (maximum 100 points) as delineated on the current food services establishment inspection report

form.

5. Good Retail Practices Categories (GRP) include:

(i) Safe food and water, food identification.

(ii) Food temperature control.

(iii) Pest and animal control.

(iv) Prevention of food contamination.

(v) Proper use of utensils.

(vi) Utensils, equipment and vending.

(vii) Water, plumbing and waste.

(viii) Physical facilities.

(ix) Other.

(i) Timely Correction of Risk Factors/ Public Health Intervention (RF/PHI) Categories and HACCP Plans.

1. Except as specified in 2. of this subsection, a person in charge shall at the time of inspection correct a violation of a Risk Factors/Public Health Interventions (RF/PHI) of this chapter and implement corrective actions for a HACCP plan provision that is

not in compliance with its critical limit.

2. Considering the nature of the potential hazard involved and the complexity of the corrective action needed, the health authority may agree to or specify a longer

time frame, not to exceed ten calendar days after the inspection, for the permit holder to correct violations of a Risk Factors/ Public Health Intervention item

or HACCP plan deviations.

3. Failure to correct these violations to the satisfaction of the health authority may result in

such emergency action as deemed necessary by the health authority including actions pursuant to O.C.G.A. §§ 31-5-2(b); 31-5-9(a).

(j) Time Frame for Correction of Good Retail Practices Categories.

1. Except as specified in 2. of this subsection, the permit holder shall correct Good Retail Practices (GRP) categories within 72 hours of the food service establishment's receipt of the inspection report or as otherwise directed by the health authority. Failure to make timely corrections to the satisfaction of the health authority of Good Retail Practices (GRP) categories may subject the food service establishment to suspension or revocation of its permit pursuant to subsection (1)(b) of this Rule.

2. The health authority may approve a compliance schedule that extends beyond the time limits

specified under 1. of this subsection if a schedule of compliance is submitted by the permit holder

and no health hazard exists or will result from allowing an extended schedule for compliance.

(k) Verification and Documentation of Correction.

1. After observing at the time of inspection a correction of a violation of a Risk Factor/Public Health Intervention (RF/PHI) item or deviation, the health authority shall enter the violation and information about the corrective action on the inspection report.

2. As specified under subsection (2)(j)2. of this Rule, after receiving notification that the permit holder has corrected a violation

of a Risk Factors/Public Health Interventions (RF/PHI) or HACCP plan deviation, or at the end of the specified period of time, the health authority shall verify correction of the violation, document the information on an inspection

report or addendum, and enter the report in the health authority's records.

(l) Grading Inspections. Inspections will receive a letter grade based on the numerical score as follows:

1. "A". The letter grade "A" means food safety excellence and is applied to numerical score of 90 to 100.

2. "B". The letter grade "B" means satisfactory compliance and is applied to numerical score of 80 to 89.

3. "C". The letter grade "C" means marginal compliance and is applied to numerical score of 70 to 79.

4. "U". The letter grade "U" means unsatisfactory compliance and is applied to numerical score of 69 or less.

(m) Repeat Violations. A repeat violation means a violation of the same code provision of this chapter under an item in a Risk Factors/Public Health Interventions (RF/PHI) or Good Retail Practices (GRP) category as documented in the previous routine inspection. A repeat violation constitutes the initial point deduction as specified in

subsection (2)(h)2. and 4. of this Rule plus an additional two point deduction for one or more repeat violation(s) within a RF/PHI category and one

point deduction in a GRP category from the overall score (maximum 100 points). If a repeat violation of the same code provision of this chapter occurs for three consecutive routine inspections, then the points will be deducted accordingly and the food service establishment may be subject to suspension or revocation of its permit

pursuant to subsection (1)(b) of this Rule.

(n) Follow-up Inspections.

1. A follow-up inspection means a complete inspection done as a result of a routine inspection. A follow-up inspection will be conducted when the establishment earns a "C" or "U" grade on a

routine inspection. If a grade of "C" or higher is earned on the follow-up inspection, then no additional follow-up inspections will be conducted, however all RF/

PHI violations must be corrected as specified under subsection 2(j)1.—3. of this Rule.

2. The new score and equivalent grade will be posted on an inspection report during a follow-up inspection. The two previous inspection grades and scores, whether routine and/or follow-up inspections, will be posted subsequently under "Last Grade, Score and

Date" and "Prior Grade, Score and Date" on the inspection report.

(o) Informal Follow-up Inspection. If a follow-up inspection as specified in subsection (2)(n) of this Rule cannot be conducted by the health authority, then an informal follow-up may be performed to confirm correction of the violations that were cited on the routine inspection that were not corrected at the time of the inspection.

On an informal follow-up inspection, an inspection report addendum(s) will be completed, documenting the violations that have been corrected. It will be noted on the addendum(s) that this

was an informal follow-up inspection, and the establishment will keep the same grade that was earned on the previous routine inspection. The addendum(s) will be made available by the food service establishment to the

public upon request.

(p) Voluntary Closure.

1. A food service establishment that is graded as a "U" and does not earn at least a grade "C" within ten days of receiving the "U" will be requested to voluntarily close until all violations are corrected and/or have enforcement action taken to suspend or revoke the food service permit according to subsection (1)(b) of this Rule.

2. A food service establishment that is graded as a "U" on two consecutive routine inspections will be asked to voluntarily close until

all violations are corrected and/or have enforcement action taken to suspend or revoke the food service permit pursuant to subsection (1)(b) of this Rule.

(3) Examination, Condemnation and Public Notice.

(a) Examination of Food. Food may be examined or sampled by the health authority when necessary to determine freedom from adulteration or misbranding.

(b) Condemnation of Food.

1. The health authority may, upon written notice to the owner or person in charge, place a hold order on any food that the health authority determines or has probable cause to believe to be unwholesome or otherwise adulterated, or misbranded. Under a hold order, food shall be moved to a

suitable holding area for storage until a hold order release or destruction order is issued. No food subject to a hold order shall be

used, served, or removed from the establishment except as specified in 2. of this subsection. Immediate destruction shall be ordered and accomplished if there is risk to public health.

2. If the health authority has reasonable cause to believe that the hold order will be violated, or

finds that the order is violated, the health authority may remove the food that is subject to the order to a place of safekeeping.

3. The hold order notice shall:

(i) State that food subject to the order may not be used, sold, moved from the food service establishment, or destroyed without a written release of the order from the health authority;

(ii) State the specific reasons for placing the food under the hold order with reference to the applicable provisions of this chapter and the hazard or adverse effect created by the observed condition;

(iii) Completely identify the food subject to the hold order by the common name, the label information, a container description, the quantity, health authority's tag or identification information, and location;

(iv) State that the permit holder has the right to an appeal hearing and may request a hearing within 72 business hours of the health authority;

(v) State that the health authority may order the destruction of the food if a timely request for a hearing is not

received; and (vi) Provide the name and address of the health authority representative to whom a request for an appeal hearing may be made.

(4) Procedure When Infection is Suspected.

(a) Investigation and Control. The health authority shall act when it has reasonable cause to believe that a food employee or conditional employee has

possibly transmitted disease; may be infected with a disease in a communicable form that is transmissible through food; may be a carrier of

infectious agents that cause a disease that is transmissible through food; or is affected with a boil, an infected wound, or acute respiratory infection, by:

1. Securing a confidential medical history of the food employee or conditional employee suspected of transmitting disease or making other investigations as deemed appropriate; and

2. Requiring appropriate medical examinations, including collection of specimens for laboratory analysis, of a suspected food employee or conditional employee.

(b) Restriction or Exclusion of Food Employee, or Summary Suspension of Permit. Based on the findings of an

investigation related to a food employee or conditional employee who is suspected of being infected or diseased, the health authority may issue an order to the suspected food employee, conditional employee or permit holder instituting one or more of the following control measures:

1. Restricting the food employee or conditional employee;

2. Excluding the food employee or conditional employee; or

3. Closing the food service establishment by summarily suspending a permit to operate in accordance

with law.

(5) Variance.

(a) Modifications and Waivers. The department may grant a variance by modifying or waiving the requirements of this chapter if in the opinion of the department a health hazard or

nuisance will not result from the variance. If a variance is granted, the department shall retain the information specified under subsection 5.(b) of this Rule in its records for the food

service establishment.

(b) Documentation of Proposed Variance and Justification. Before a variance from a requirement of this chapter is approved, the information that shall be provided by the person requesting the variance and retained in the department's file on the food service establishment includes:

1. A statement of the proposed variance of the chapter requirement citing relevant rule and subsection numbers;

2. An analysis of the rationale for how the potential public health hazards and nuisances addressed by the relevant rules and subsections will be alternatively addressed by the proposal; and

3. A HACCP plan if required that includes the information specified under Rule .02 subsections (5)(a)—(e) as it is relevant to the

variance requested.

(c) Conformance with Approved Procedures. If the department grants a variance as specified in subsection (5)(a) of this Rule, or a HACCP plan is

otherwise required as specified under Rule .02 subsections (5)(a)—(e), the permit holder shall:

1. Comply with the HACCP plans and procedures that are submitAPPENDIX C—BOARD OF HEALTH RULES 290-5-14-.10 ted as specified under Rule .02

subsections (5)(a)—(e) and approved as a basis for the modification or waiver; and

2. Maintain and provide to the department, upon request, records specified under Rule .02 subsections (5)(d) and (e) that demonstrate that the following are routinely employed;

(i) Procedures for monitoring the critical control points, (ii) Monitoring of the critical control points, (iii) Verification of the effectiveness of the operation or process, and (iv) Necessary corrective actions

if there is failure at a critical control point.

(6) Implementation and Enforcement. The administration and enforcement of these rules and regulations shall be as prescribed in O.C.G.A. § 31-5. Implementation of these rules and regulations shall begin nine months after the effective date.

(7) Penalty. Any person who violates any provision of this Article or any rule or regulation promulgated under O.C.G.A. § 26-2, Article 13 by the health authority shall be

guilty of a misdemeanor.

Authority O.C.G.A. §§ 26-2-373, 31-2-4. Administrative History. Original Rule entitled "Violations" was filed and effective on July 19,1965 as 270-5-6-14-.10.

Amended: Rule repealed and a new Rule entitled "Personnel" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as

290-5-14-.10. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Protective Shielding" adopted. Filed July 10, 1986;

effective July 30, 1986. Amended: Rule repealed and a new Rule of the same title adopted. Filed March 5,

1996; effective March 25, 1996. Amended: Rule repealed and a new Rule entitled "Compliance Procedures" adopted. Filed Jan. 26, 2006; effective Feb. 15, 2006. Amended: Rule repealed and a new Rule of same title adopted. Filed Jan. 24, 2007; effective Feb. 13, 2007. Repealed: New Rule of same title adopted. Filed August 23, 2007; effective Sept. 12, 2007.

290-5-14-.11. Repealed.

Authority O.C.G.A. 26-2-371 and 372, 375-377, 31- 2-1, 31-2-4, Chapter 31-5. Administrative History. Original Rule entitled "Denial, Suspension or Revocation" was filed and effective on July 19,1965 as 270-5-6-.11.

Amended: Rule repealed and a new Rule entitled "Food Equipment and Utensils" adopted. Filed January 25,

1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.11. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Compliance Procedures" adopted. Filed July 10, 1986; effective July 30, 1986. Amended: Rule repealed and a new Rule of the same title adopted.

Filed March 5, 1996; effective March 25, 1996. Repealed: Filed Jan. 26, 2006; effective Feb. 15, 2006.

290-5-14-.12. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Administrative Hearings" was filed and effective on July 19,1965 as 270-5-6-.12. Amended: Rule repealed and a new Rule

entitled "Equipment Installation" adopted. Filed January 24, 1967; effective February 12, 1967. Amended:

Rule renumbered as 290-5-14-.12 Filed June 10, 1980;

effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.13. Repealed.

Authority Ga. 1964, pp 507, 559. Administrative History Original Rule entitled "Personal Service" was filed and effective on July 19,1965 as 270-5-6-.13.

Amended: Rule repealed and a new Rule entitled "Cleanliness of Equipment and Utensils" adopted. Filed January 24, 1967; effective February 12, 1967. Amended:

Rule renumbered as 290-5-14-.13. Filed June 10, 1980;

effective June 30, 1980. Amended: Rule repealed, Filed July 10, 1986; effective July 30, 1986.

290-5-14-.14. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Unwholesome Food or Food Products" was filed and effective on July 19,1965 as 270-5-6-.14. Amended: Rule repealed and a new Rule entitled "Storage and Handling of Cleaned Equipment and Utensils" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.14. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986;

effective July 30, 1986.

290-5-14-.15. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Withhold from Sale Orders" was filed and effective on July 19,1965 as

270-5-6-.15. Amended: Rule repealed and a new Rule entitled "Single-Service Article" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.15. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.16. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Condemnation" was

filed and effective on July 19,1965 as 270-5-6-.16.

Amended: Rule repealed and a new Rule entitled "Sanitary Facilities and Controls" adopted. Filed January 24, 1967; effective February 12, 1967. Amended:

Rule renumbered as 290-5-6-.16. Filed June 10, 1980;

effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.17. Repealed.

Authority Ga. L. 1964, pp 507, 559. Administrative History. Original Rule entitled "Communicable Diseases" was filed and effective on July 19,1965 as 270-5-6-.17. Amended: Rule repealed and a new Rule

entitled "Vermin Control" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.17. filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986, effective July 30, 1986.

290-5-14-.18. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Permits, Suspension and Emergency" was filed and effective on July 19,

1965 as 270-5-6-.18. Amended: Rule repealed and a new Rule entitled "Other Facilities and Operations" adopted. Filed January 24, 1967; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.18. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.19. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Sanitation Requirements for Permit" was filed and effective on July 19, 1965 as 270-5-6-.19. Amended: Rule repealed and a new Rule entitled "Temporary Food Service Establishments" adopted. Filed January 24, 1967; effective February 12, 1967. Amended Rule renumbered as 290-5- 14-.19. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.20. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original rule entitled "Inspection of Food Service Establishments" was filed on January 24, 1967 as 270-5-6-.20; effective February 12, 1967. Amended:

Rule renumbered as 290-5-14-.20. Filed June 10, 1980;

effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.21. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Plan Review of Future Construction" was filed on January 24, 1967 as 270-5- 6-.21; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.21. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed. Filed July 10, 1986; effective July 30, 1986.

290-5-14-.22. Repealed.

Authority Ga. L. 1964, pp. 507, 559. Administrative History. Original Rule entitled "Enforcement" was filed on January 24, 1967 as 270-5-6-.22; effective February 12, 1967. Amended: Rule renumbered as 290-5-14-.22.

Filed June 10, 1980; effective June 30, 1980. Amended:

Rule repealed. Filed July 10, 1986; effective July 30, 1986.

CHAPTER II. ON-SITE SEWAGE

MANAGEMENT*

290-5-26-.01. Applicability.

These Rules will have application in all except the following cases:

(a) Any facility or system under the jurisdiction of and regulated by the Department of Natural Resources or its successor;

(b) Any public or community sewage treatment system;

(c) Other shared jurisdiction by Memoranda of Agreement or other agreements.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Definitions" was filed on December 1, 1969 as 270-5-25-.01; effective December 20, 1969. Amended: Rule renumbered as 290-5-26- .01. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule entitled "Applicability" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended:

ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER.

Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.02. Definitions.

For the purpose of this chapter, the following words and phrases shall have the meaning as indicated beside each listing:

(a) "Absorption field" means a configuration of absorption trenches installed in a portion of land and used for the

absorption and final treatment of sewage.

(b) "Absorption line" means a pipe line of perforated pipe laid in an absorption trench to serve as a conduit for sewage effluent.

(c) "Absorption trench" means an excavation in which an absorption line is laid.

(d) "Absorption trench bottom and side soil area" means the total interface of bottom and side soil area with undisturbed soils of all absorption

trenches in an absorption field and occurring horizontally and downward from the point of distribution into the soil, expressed in square feet.

(e) "Aggregate" means washed gravel or washed stone meeting the Georgia Department of Transportation standards for hardness or other materials approved by the department that shall

be 1 /2-inch to two inches in diameter.

(f) "Alternative on-site sewage management system" means any approved on-site sewage management system which differs in design or operation from the conventional or chamber septic tank system or privy.

(g) "Approved" or "approval" means compliance with applicable specifications or criteria developed or accepted by

the department.

(h) "Auxiliary system" means a system to serve a portion of a residence, a pool house or other adjunct facility.

(i) "Bedroom" means any room that is designed primarily for sleeping purposes, as shown on the building plan.

(j) "Black water" means wastewater generated by water closets, urinals, bidets, kitchen sinks and garbage disposals.

(k) "Building drain" means that part of the lowest piping of a building drain- age system inside the walls of a building, which receives the discharge from soil, waste or other drainage systems

and conveys the discharge to the building sewer.

(l) "Building sewer" means that part of the horizontal piping of a building drainage system beyond the building drain which receives the discharge from the building drain and conveys it to a public sewer, private sewer, onsite sewage management system or other disposal.

(m) "Central on-site sewage management system" means an on-site sewage management system serving more than one building, business, residence

or other facility designed or used for human occupancy or congregation.

(n) "Chamber septic tank system" means a septic tank and a chamber system as defined in (o).

(o) "Chamber system" means a system of chambers with each chamber being a molded polyolefin plastic, arch shaped, hollow structure with an exposed bottom area and solid top and louvered sidewall for infiltration of

effluent into adjoining bottom and sidewall soil areas. Chambers may be of different sizes and configurations to

obtain desired surface areas.

(p) "Community subsurface treatment system" means any system which treats primarily domestic wastewater other than those serving single family residences or non-domestic sewage systems.

(q) "Conventional system" means a traditionally used system that is composed of perforated pipe surrounded by gravel or stone masking for the

infiltration of effluent into adjoining bottom and side soil areas.

(r) "Conventional septic tank system" means any septic tank and conventional system as defined in (q), but does not include alternative or experimental systems.

(s) "County board of health" means the county board of health established by the Official Code of Georgia Annotated (O.C.G.A. 31-3-1) or its designee.

(t) "Department" means the Department of Human Resources of the State of Georgia or its designee.

(u) "Distribution device" means a watertight structure which receives sewage effluent from a septic tank, dosing tank or other sewage retention device

and distributes it in equal portions to two or more absorption lines.

(v) "Dosing tank" means an approved watertight tank, located after a septic tank or other sewage retention device, to receive and retain sewage effluent, and so equipped as to discharge sewage effluent intermittently to a distribution device, either by pump or by siphon.

(w) "Experimental on-site sewage management system" means any on-site sewage management system proposed

for testing and observation, and provisionally approved for such purposes by the department, but which has not

been fully proven under field use.

(x) "Failure" means an on-site sewage system in such a condition that it constitutes a public hazard by inadequate treatment and/or disposal of sewage.

(y) "Filter" means an approved device that removes solids or other materials from the effluent that could cause failure of an on-site sewage management system.

(z) "Flood plain" means a generally flat plain or depression susceptible to being flooded from any source, including small and intermittent water courses

and coastal areas subject to intermittent tidal action.

(aa) "Gray water" means wastewater generated by water-using fixtures and appliances, excluding water closets,

urinals, bidets, kitchen sinks and garbage disposals.

(bb) "Grease trap" means a device in which the grease content of sewage is intercepted and congealed, and from which grease may be skimmed or otherwise

removed for proper disposal.

(cc) "Individual water supply system" means a system of piping, pumps, tanks or other facilities, utilizing groundwater to supply a single family dwelling.

(dd) "Lot" means a portion of a subdivision, or any other parcel of land, intended as a unit for transfer of ownership, or for development, or both, and shall not include any part of the

right-of-way of a street or road.

(ee) "Manual for On-Site Sewage Management Systems" means the technical handbook currently adopted and periodically updated which is used by

the department in the implementation of this chapter and is available for inspection at the appropriate State

Office in Atlanta or at local health departments. The Manual for On-Site Sewage Management Systems and its provisions are herein adopted unless inconsistent with other provisions of law or regulation and is hereafter referred to as the "manual" or "Manual for On-Site Sewage Management Systems."

(ff) "Mobile home park" means a parcel of land developed for subsequent rental or lease or placement of two or more mobile homes.

(gg) "On-site sewage management system" means a sewage management system other than a public or community sewage treatment system serving one or more buildings, mobile homes,

recreational vehicles, residences, or other facilities designed or used for human occupancy or congregation.

Such term shall include, without limitation, conventional and chamber septic tank systems, privies, and experimental and alternative on-site management systems which are designed to be physically incapable of a surface discharge of effluent that may

be approved by the department.

(hh) "Percolation coefficient" means the ratio of trench bottom area to percolation time; it is expressed as the allowable rate of sewage application in gallons per square foot per day.

(ii) "Percolation rate" means the time, expressed in minutes per inch, required for water to seep into saturated soil at a constant rate.

(jj) "Percolation test" means the method used to measure the percolation rate of water into soil as described in the department's current Manual for OnSite Sewage Management Systems.

(kk) "Person" means any individual, partnership, corporation, or association and may extend and be applied to bodies,

both political and corporate.

(ll) "Physical development" means development which includes, but is not limited to site preparation, erection of

a structure, road construction, well construction or installation of on-site sewage management systems.

(mm) "Privy" means a structure (and necessary appurtenances) used for the sanitary disposal or storage of human

wastes without the aid of water carriage; the term does not include chemical, composting, portable or incinerator toilets.

(nn) "Public water supply system" means a system for the provision of piped water to the public for human consumption, if such system has at least 15 service connections, or regularly

serves an average of at least 25 individuals daily, at least 60 days out of the year.

(oo) "Septage" means a waste that is a fluid mixture of partially treated or untreated sewage solids, liquids and sludge of human or domestic waste, present in or pumped from septic tanks, malfunctioning on-site sewage management systems, grease traps or privies.

(pp) "Sewage treatment system" is a system that provides primary treatment and disposal, including absorption field components, devices and appurtenances intended to be used for disposal of sewage by soil absorption,

but does not include a conventional or chamber septic tank system. The system shall be designed to be physically incapable of a surface discharge of

effluent.

(qq) "Septic tank" means an approved watertight tank designed or used to receive sewage from a building sewer and to affect separation and organic decomposition of sewage solids, and discharging sewage effluent to an absorption field or other management system.

(rr) "Sewage" means and includes human excreta, all water carried wastes, and liquid household waste from residences or commercial and industrial establishments.

(ss) "Sinkhole" means a depression in the land surface, generally in a limestone region, which communicates or has the potential to communicate with a subterranean passage developed by solution; typical sinkholes can be broad, closed basin-like features or steepsided dropouts, or variants thereof.

(tt) "Site" means the location where the absorption field will be installed to include replacement area.

(uu) "Soil classifier" means a person who holds at least a Bachelor of Science degree from an accredited college or university with a major in Agronomy, Soil Science, or related field, as approved by the Soil Classifiers Certification Advisory Committee. Must have completed a minimum of 15 semester

hours or 25 quarter hours in approved soil science courses including a course in pedology and have four years or more of full time experience as a Soil Classifier/Soil Scientist actively mapping, identifying and classifying soil features, and interpreting the influence of soil features on soil uses. Certification shall be in accordance with guidelines published in the Manual

for On-Site Sewage Management Systems.

Any person who holds a valid certificate of registration as a geologist issued pursuant to O.C.G.A. Chapter 19 of Title 43, or who holds a valid certificate of registration as an engineer issued pursuant to O.C.G.A. Chapter

15 of Title 43 and is practicing within his or her area of engineering competency may register with the department as a Soil Classifier.

(vv) "Subdivision" means any division of a tract or parcel of land into five or more lots, building sites, mobile home sites, or other divisions, resulting in any single lot of less than three acres, for the purpose, whether immediate or future, of sale or legacy, and includes resubdivision and, where appropriate to the context, relates to the process of subdividing or to the land

or area subdivided, provided; however; that the following are not included within this definition:

1. The combination or recombination of previously platted lots or portions thereof where the total

number of lots is not increased and the resultant lots conform to the standards of these rules.

2. The division of land into parcels, all of which are three acres or more in size with minimum width of 150 feet for a distance sufficient to provide an adequate area for the placement of structures

and improvements including wells and approved installation of approved on-site sewage management systems.

(ww) "Well" means an excavation or opening into the ground by which groundwater is sought or obtained.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "General Provisions" was filed on December 1, 1969, as 270-5-25-.02; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.02. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Definitions" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended:

ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER.

Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.03. General Provisions.

(1) "On-Site Sewage Management System Required"—Where public or community sewage treatment systems are not available, the owner, lessee or agent thereof of every building, residence or property, designed, used or intended to be used for human occupancy or

congregation, shall provide an approved onsite sewage management system sufficient for persons normally expected to use or frequent the building, residence or other property for two hours or more. Connection shall be made to a public or community sewage

treatment system when such system is available within 200 feet of the property line, or available in a public right-of-way abutting

the property. Where a public or community sewage treatment system is to be constructed, or an existing public or community sewer is to be extended to serve a lot, or an approved on-site sewage management system is to be used, the building sewer shall be installed so that it will insure gravity flow at a selfcleaning velocity throughout. If an existing on-site sewage system fails, immediate connection shall be made to a public or community sewage system if such a system is available.

(a) Any facility that produces a waste stream with BOD5 (Biochemical Oxygen Demand) and TSS (total suspended solids) higher than 200 mg/L shall be required to pretreat the waste

to reduce the BOD5 and TSS to 200 mg/L or below before disposal through a conventional or chamber septic tank system.

(2) "On-Site Sewage Management System Construction Permit Required"—No person may begin the physical development of a lot or structure thereon, where an on-site sewage management system will be utilized, nor install an on-site sewage management system or component thereof without having first applied for and obtained from the county

health department a construction permit for the installation.

(a) Application for such a construction permit shall be made in writing on forms provided by the county board of health. The county board of health shall approve or disapprove such application within twenty days after the receipt of a completed application. The

application shall include:

1. Name and address of the owner and the applicant, if other than the owner;

2. Location of property;

3. Plans and specifications including location and design of the proposed on-site sewage management system including surface and subsurface drainage and piping;

4. Nature of the facility to be served;

5. Location of all water supplies, geothermal systems, or other utilities and trash pits on or off the lot, which will bear upon the location of the on-site sewage management system;

6. Number of bedrooms in the dwelling, or the number of persons to be served in other types of establishments, or other sewage flow or water usage data;

7. Soil characteristics, including soil types and capabilities, frequency and evaluations of seasonal high groundwater tables, occurrence of rock and other impervious strata;

8. Signature of the owner or agent applying for permit; and

9. Any additional information deemed necessary to determine the suitability of the site.

(b) The county board of health may waive submission of part of the information required for the application, provided the board deems that such information is available from previously submitted subdivision or mobile home park data, or from other sources. The

information must be sufficient to make an adequate appraisal of the acceptability of the proposed lot for the installation of an on-site sewage management system.

(c) Repairs, replacement, or additions to existing systems must be permitted and inspected.

(d) Any person preparing to modify a lot for the purpose of obtaining a construction permit for the installation of an on-site sewage management system

shall submit plans showing the type and extent of modifications. No modifications shall be carried out prior to the approval of the plans by the county

board of health. Such approval shall be in accordance with the provisions of the department's current Manual for On-Site Sewage Management Systems.

(3) "Requirements for On-Site Sewage Management System Construction Permit Issuance or Denial"—On-site sewage management system construction permits shall be issued only after a site inspection by the

county board of health shows favorable findings relative to absorption rates, soil characteristics, groundwater, rock and any other factors which would affect the acceptability of

the lot. No construction permit for an on-site sewage management system shall be issued prior to the approval of the public water supply system, where a public water supply system is to be utilized. Lot suitability and approval is to be determined by the criteria established by the department's current Manual for On-Site Sewage Management Systems.

Lots shall be sized according to the regulations of the county board of health. The county board of health may deny or revoke an

on-site sewage management system construction permit upon finding the lot unsuitable or for failure of the applicant to comply with the

provisions of these rules. Such denial shall be made in accordance with the provisions of

O.C.G.A. §§ 12-8-1, 31-5-2, 31-5-3, 31-5-4,

31-5-5 and 31-5-6. On-site sewage management construction permits shall remain valid for not more than 12 months from the date of

issue.

(a) Issuance of a construction permit for an on-site sewage management system, and subsequent approval of same by representatives of the county board

of health shall not be construed as a guarantee that such systems will function satisfactorily for a given period of time; furthermore, said representatives do not, by any action taken in affecting compliance with these rules,

assume any liability for damages which are caused, or which may be caused, by the malfunction of such system.

(b) On tracts or parcels of land of three acres or more, the conventional or chamber septic tank system may be utilized where the percolation rate does not exceed 120 minutes per inch.

All other conditions must comply with the requirements of the regulations for on-site sewage management systems.

(4) "Inspections"—No person may backfill or use an on-site sewage management system until final inspection has been made by the county board of health to determine compliance with the provisions of the construction permit issued under Section 290-5-26-.03(3)

and written approval has been issued by the county board of health.

(a) A copy of the final inspection of an on-site sewage management system shall be provided to the owner, builder, developer or agent, whichever is appropriate.

(b) Grading, filling, digging trash pits or other landscaping or construction activities on the lot subsequent to final inspection by the county board of health

which may adversely affect the on-site sewage management system shall render the approval void. Removal or alteration of system components after

final inspection by the county board of health shall render the approval void.

(5) "Design Limits for Conventional or Chamber Septic Tank Systems"—To provide for the maintenance of sanitary conditions through the proper functioning of a conventional or chamber septic tank system for a reasonable period of time, no such system

may be installed, constructed, or used, having a septic tank design capacity of less than 1,000 gallons or greater than 10,000 gallons,

or where the total length of absorption trenches required would exceed 3,000 linear feet, or where the total absorption trench bottom area required would exceed 9,000 square feet.

(6) "Submission of Plans, Specifications, and Soil Data"—Plans, specifications, soil data and, if required, absorption test data, submitted to the county board of health for the purpose of obtaining a construction permit to install an on-site sewage management system, which will produce a sewage flow in

excess of 2,000 gallons per day, shall bear the registration number and signature of a Registered Professional Engineer, certified and registered under the laws of this State. The

county board of health may accept plans, specifications, soil data, and absorption test data for facilities with sewage flow of 2,000 gallons or less per day, when prepared in accordance with these rules, from any person who demonstrates to the satisfaction of the county board of health that they have sufficient knowledge of on-site sewage management system design.

(7) "Soil Data Acceptability for Individual Lots"—Soil evaluations shall be conducted by individuals meeting the requirements established in the department's current Manual for On-Site Sewage Management Systems.

(8) "Soil Data or Design Certification required"—The soil classifier, engineer, geologist or other professional approved by the department shall be required to attach to any

soil evaluation submitted to the county board of health a copy of a current in force liability insurance certificate with limits of liability of no less than $1,000,000.00.

Soil evaluation reports submitted in compliance with the requirements established by the Soil Survey Report Checklist in Section C

of the department's Manual shall be deemed sufficient and shall be accepted. The county board of health shall issue on-site sewage management system permits on sites deemed suitable by soil evaluations conducted in accordance with requirements established by the checklist in Section C of the department's

Manual. In the event the county board of health finds the soil evaluation is deficient, it shall notify the person or entity that submitted the evaluation in writing by mail within three business days stating all deficiencies

and measures needed to correct deficiencies.

Engineer designs submitted in compliance with the requirements established by the Engineered Site Plan Checklist in Section F of the department's Manual and submitted with a copy of current in force liability insurance certificate with limits of liability of no less than $1,000,000.00 shall be accepted by

the county board of health. Engineer designs shall be evaluated within 20 days of submission and a written determination of said evaluation shall be mailed to the submitter

within three business days of the findings by the county board of health. If the engineer design is rejected, the county board of health shall so notify the submitter listing the deficiencies found, the measures needed to correct the deficiencies and of the submitter's right to appeal the county's decision.

(9) "On-Site Sewage Management System Notice required"—In the event an on-site sewage management system, alternative system or soil fill installation is installed, notice shall be delivered to the owner of such property and in the event of new construction homes or commercial buildings, notice must

be delivered to new owner, by the homebuilder/ contractor, at the time of conveyance on such property stating the type of installation, design and maintenance needs.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Sewers" was filed on December 1, 1969, as 270-5-25-.03; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.03.

Filed June 10, 1980; effective June 30, 1980. Amended:

Rule repealed and a new Rule entitled "General Provisions" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has

been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended:

ER. repealed and permanent Rule, same title adopted.

Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency. Amended: Jan. 17, 2007; eff. April 1, 2007, as specified by Agency.

290-5-26-.04. Sewers.

(1) "Size of Sewers"—Sewers connecting component parts of on-site sewage management systems shall be of sufficient size to serve anticipated flow conditions.

(2) "Sewers"—All solid pipe and fittings used in an on-site sewage management system, beginning at the house, shall be NSF International schedule 40 PVC or equivalent

and shall be a minimum of four inches in diameter. Sewers under driveways or similar areas of load or impact shall be of material capable of withstanding anticipated loads or installed so as to provide protection from crushing.

(3) "Construction"—Sewers, other than perforated pipe or drain tiles used in absorption fields, shall be laid with sealed, watertight,

root-resistant joints. Such sewers shall be laid on a firm foundation, shall not be subject to settling, and shall be installed on a grade that will insure a self-cleaning velocity. Where on-site sewage management systems are used, and where installation of building drains and building sewers is not covered by duly adopted local plumbing codes, or in the absence of a local plumbing code and/or plumbing

inspections, the county board of health may verify the adequacy and acceptability of all or any portion of the building sewer or the building drain.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Septic Tanks" was filed on December 1, 1969, as 270-5-25-.04; effective December 20, 1969. Amended: Rule renumbered as 290-5-26- .04. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule entitled "Sewers" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended:

ER. repealed and permanent Rule, same title adopted.

Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.05. Septic Tanks.

(1) "Minimum Design and Construction"— Septic tanks shall provide a minimum of 24 hours of retention and shall be designed and constructed to equal or exceed minimum design and construction criteria established by the department as published in the current

Manual for On-Site Sewage Management Systems. After the effective date of these regulations, any person seeking approval of septic tanks to be used in on-site sewage management systems, shall submit detailed plans and specifications for tank manufacture and

other information as may be required by the department. Manufacturers and suppliers may be subject to periodic inspection, and approval by the county board of health or the department. Both the inlet and outlet tees

shall be ASTM 3034 rated or equivalent. In addition, an approved filter shall be installed on the outlet end of the septic tank in compliance with the Manual for On-Site Sewage Management Systems.

(2) "Location"—No septic tank shall be installed less than fifty feet (50') from existing or proposed wells/springs, sink holes, or suction water lines, and tanks shall be located downgrade from wells or springs if physically possible; less than twenty-five feet

(25') from lakes, ponds, streams, water courses, and other impoundments; less than ten feet (10') from pressure water supply lines, or less than ten feet (10') from a property line. No septic tank shall be installed less than fifteen feet (15') from a drainage ditch or embankment. Septic tanks shall be installed so as to provide ready access for necessary maintenance. Normally, the distance a septic tank should be located from a building foundation

is at least ten feet (10') but, lesser distances may be allowed by the county board of health.

The county board of health, after site inspection, may require greater separation distances than cited herein due to unusual conditions of topography, or other site configuration; subsurface soil characteristics

and/or groundwater interference.

(3) "Capacity"—The liquid capacity of septic tanks for single family dwellings shall be 1,000 gallons for one, two, three or four

bedrooms, and 250 additional gallons for each bedroom over four. Septic tank capacity shall be increased by 50% where garbage grinders are to be used. Auxiliary systems serving single family residences or other facilities shall be based on the maximum daily flow.

(4) "Compartmented Tanks"—Two compartment tanks shall be required. The first compartment shall be at least 2 /3 the liquid capacity of the tank.

(5) "Tanks in Series"—The county board of health may approve the installation of two septic tanks placed in series provided that the capacity of the first tank is at least 1,000 gallons and at least equal to the capacity of the second tank. When tanks in series are used, they shall be connected with a sealed sewer line, and all sewage shall initially enter the first tank.

(6) "Foundation and Backfill"—Septic tanks will be constructed or installed level, on a foundation that will prevent settling; backfill shall be placed so that a stable fill results and undue strain on the tank is avoided. Earth backfill shall be free of voids, large stones, stumps, broken masonry, or other such materials. A minimum earth cover of six inches over the tank is recommended. With proper

documentation the county board of health may approve less cover. All openings and manholes shall be constructed so as to prevent the entrance of surface water.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Distribution Boxes" was filed on December 1, 1969, as 270-5-25-.05; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.05. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Septic Tanks" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended:

ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER.

Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.06. Distribution Devices and Dosing Tanks.

(1) "Minimum Design and Construction of Distribution Devices"—Distribution devices shall be designed and constructed in accordance with minimum design and construction criteria established in the department's current Manual for On-Site Sewage Management Systems.

(2) "Minimum Design and Construction of Dosing Tanks"—Where required, dosing tanks shall be designed, constructed, and installed in accordance with the department's current Manual for On-Site Sewage Management Systems.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Nitrification Fields" was filed on December 1, 1969, as 270-5-25-.06; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.06. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Distribution Boxes and Dosing Tanks" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan.

2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter

superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998;

eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.07. Absorption Fields.

(1) "Absorption Area"—The absorption area shall be based upon the anticipated volume of treated sewage and upon the characteristics of the soil in which absorption fields are to be located as specified in the department's current Manual for On-Site Sewage Management Systems. Soil characteristics and other related data, including percolation tests, may

be required by the county board of health.

Absorption areas shall be classified as follows: aggregate, non-aggregate and other.

(2) "Prior Approved Systems"—Any "Prior approved system" as defined in the Official Code of Georgia Annotated 31-2-7(a)(4) is approved for installation according to the manufacturer's recommendation.

(3) "Location"—No absorption field will be constructed less than 100 feet from existing or proposed wells, springs or sinkholes; less than ten feet from water supply lines and buildings with basements and less than five feet from buildings without basements, other structures, drives and property lines; less than 15 feet from an embankment, drainage ditch or trash pits; not less than 50 feet from the normal water level of any impoundment, tributary, stream, or other body of water, including ponded areas of wetlands. If the water supply line crosses or comes within ten feet of the absorption field, the water supply line shall be installed at least 12 inches above the top of the aggregate layer of the absorption line, non-aggregate absorption line or other absorption line, and shall be encased in

a single length of larger diameter water pipe.

No absorption field shall be installed in areas where groundwater, soil characteristics or adverse geological formation may interfere with the absorption or effective treatment of sewage effluent.

(4) "Minimum Design and Construction for Absorption Fields"—Absorption lines and absorption trenches shall be designed and installed in accordance with the minimum design and installation criteria established in the department's current Manual for OnSite Sewage Management Systems.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Subdivisions" was filed on December 1, 1969, as 270-5-25-.07; effective December 20, 1969. Amended: Rule renumbered as 290-5-26- .07. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule entitled "Absorption Fields" adopted. Filed March 28, 1984;

effective April 27, 1984, as specified by the Agency.

Amended: ER. has been adopted. Filed Jan. 2, 1998; eff.

Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended: ER. repealed and permanent Rule, same

title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.08. Privies.

"Minimum Design and Construction"— Privies shall be designed and constructed in accordance with minimum design and construction criteria established by the department's current Manual for On-Site Sewage Management Systems.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Pit Privy" was filed on December 1, 1969, as 270-5-25-.08; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.08.

Filed June 10, 1980; effective June 30, 1980. Amended:

Rule repealed and a new Rule entitled "Privies" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended: ER.

repealed and permanent Rule, same title adopted.

Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.09. Alternative On-Site Sewage Management Systems.

(1) "Alternative On-Site Sewage Management System" means any approved on-site sewage management system which differs in

design or operation from the conventional or chamber septic tank or privy.

(2) "Design and Construction"—Alternative on-site sewage management systems shall be designed and constructed in accordance

with the minimum design and construction criteria established by the department's current Manual for On-Site Sewage Management Systems. The department shall maintain a list of approved alternative on-site sewage management systems.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Soil Data and Percolation Tests" was filed on December 1, 1969, as 270-5-25- .09; effective December 20, 1969. Amended: Rule renumbered as 290-5-26-.09. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Alternative and Experimental On-Site Sewage Management Systems and Site Modifications" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended: ER.

repealed and permanent Rule, same title adopted.

Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.10. Experimental On-Site Sewage Management Systems.

"Experimental On-Site Sewage Management System" means any on-site sewage management system proposed for testing and observation, and provisionally accepted for

such purposes by the department's technical review committee. Any limitations to the use of experimental systems shall be decided by the department's technical review committee.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 431-2-4, 31- 2-7. History. Original Rule entitled "Grease Traps" was filed on December 1, 1969, as 270-5-25-.10; effective December 20, 1969. Amended: Rule renumbered as

290-5-26-.10. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Percolation Tests and Test Borings" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan.

2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter

superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998;

eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.11. Septage Removal and Disposal.

(1) "Permit Required"—No person shall engage in the removal or disposal of the contents of septic tanks, pit privies, or other on-site sewage management or experimental systems without having first applied for and obtained from either the department or a county board of health a septage removal permit, renewed annually, for such activities.

The application for such septage removal permit shall be submitted in writing on forms provided by the department or the county board of health at least ten days prior to engaging in such activities. The application shall include but not be limited to: the business name and address, name and address of the applicant, the manner by which such

contents are to be removed, transported and given final disposal, and such other documentation as may be required by the county board of health, including evidence that

septage removed and transported will be accepted at approved disposal sites.

(a) Suspension and Revocation—The permit shall be subject to suspension and revocation for failure to comply with

the requirements of these regulations or the department's current Manual for On-Site Sewage Management Systems.

(2) "Pumping and Disposal Methods"— Approved methods of pumping and disposal of septage from on-site sewage management systems shall be: discharge to a public or community sewage treatment system for treatment in treatment plant, treatment at separate septage handling facilities, or direct land application. Pumping and disposal shall be in

accordance with the requirements of the department's current Manual for On-Site Sewage Management Systems.

(3) "Vehicle Identification"—The name and address of the person or firm engaging in the removal of septage from on-site sewage management systems and the permit number shall be lettered on both sides of each vehicle

used for septage removal purposes. Letters and numerals shall not be less than two inches in height and shall be readily visible.

(4) "Vehicle Maintenance"—Every vehicle used for removal of septage from on-site sewage management systems shall be equipped with a watertight tank or body and properly maintained. Liquid wastes shall not be transported in open bodied vehicles. All pumps, hose lines, valves and fittings shall be maintained to prevent leakage.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Enforcement" was filed on December 1, 1969, as 270-5-25-.11; effective December 20, 1969. Amended: Rule renumbered as 290-5-26- .11. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule entitled "Septage Removal and Disposal" adopted. Filed March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter

superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998;

eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.12. Grease Traps.

(1) "Grease Traps Required"—Grease traps shall be required for commercial or industrial establishments with on-site sewage management systems where it is determined by the county board of health that the amount of

grease introduced into the system is in excess of 50 mg/l.

(2) "Grease Trap Design"—Plans and specifications for grease traps shall be submitted to the county board of health for approval.

The county board of health shall review the grease trap design in accordance with minimum design and construction criteria established by the department's current Manual for On-Site Sewage Management Systems.

Effluent from grease traps shall be disposed of in a septic tank and not directly discharged to the absorption field. Grease traps shall be located, installed and constructed so that the temperature of the sewage will be reduced to permit congealing or separation of grease, and easy access for cleaning is provided.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Grease Traps" was filed on March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject

matter superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.13. Sewage Flow.

The design sewage flow of an on-site sewage management system shall be determined from the department's current Manual for

On-Site Sewage Management Systems. The daily sewage flow may be determined by the department after due consideration of data submitted by the owner or his agent on design criteria. Calculations will be made on the basis of peak flow and not on long term averages.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Sewage Flow" was filed on March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject

matter superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.14. Subdivision and Mobile Home Parks.

(1) "Pre-development Review"—It is recommended that developers considering subdivision or mobile home park development, where public or community sewage treatment systems will not be available, seek a predevelopment review by the county board

of health prior to developmental improvements. A predevelopment report which indicates disapproval or tentative approval may be obtained by submitting a boundary plat

including:

(a) A vicinity map;

(b) A topographic map;

(c) A preliminary soil study conducted in compliance with the department's current Manual for On-Site Sewage Management Systems.

(2) "Proposals and Plans Required"—The following information is required for subdivision and mobile home park proposals:

(a) A boundary plat drawn to a reasonable scale which includes:

1. A vicinity map;

2. Proposed lots and streets including lot identification, dimensions, building lines and square footage

of lots;

3. A topographic map depicted in two foot contour intervals. Lesser contour intervals may be approved by the county board of health if the slope is sufficiently

steep;

4. A soil map and soil descriptions based on a high intensity soil study conducted in compliance with the department's current Manual for On-Site Sewage Management Systems;

5. The location of all present and proposed wells, water systems, water courses, flood plains, sewage systems, structures, right-ofways, utilities, storm water drainage systems and easements on the property and within 100 feet

outside the perimeter of the property; and

6. The name, registration number and seal of the professional surveyor or engineer that prepared the development plan.

(b) A completed Subdivision Analysis Record on forms provided by the department.

(c) A copy of the following documents issued by the Environmental Protection Division of the Department of Natural Resources:

1. The land disturbance activity permit issued by either the Environmental Protection Division or the local "Issuing Authority". For the

purposes of this section, "Issuing Authority" means the governing authority of any county or municipality, which is certified pursuant to subsection (a) of Code Section 12-7-8 by the director of the Environmental Protection Division;

2. A letter of approval to begin construction of a public water supply system and approving the source

of the water supply where a public water supply system is to be utilized; and

3. For a development, which will result in the disturbance of more than five acres, a copy of the Notice of Intent (NOI) submitted to the Environmental Protection Division to be covered under NPDES Permit GAR100000 for the discharge of storm water associated with construction activity.

(3) "Approval Required"—No person may sell, offer for sale, lease, rent, begin construction or otherwise begin the physical development of a lot or lots in a subdivision or mobile home park until written approval of plans for

water supply and sewage disposal has been obtained from the county board of health.

This approval constitutes general acceptance of all lots, except those lots excluded, for development with on-site sewage management systems. (Excluded lots may receive further consideration based on additional information.)

(4) "Limits on Use of On-Site Sewage Management Systems for Subdivision and Mobile Home Parks"—Approval of subdivisions and

mobile home parks utilizing on-site sewage management systems shall not be granted:

(a) When a public or community sewage system is available within 500 feet off the subdivision or mobile home park;

(b) When soil maps, descriptions, and reports compiled by a registered Soil Classifier indicate that soil conditions

prohibit safe development of on-site sewage management systems.

(c) Prior to receipt of a letter(s) from the Environmental Protection Division approving the plans to construct the public water supply system and approving the source of the water supply where a public water supply system is

to be utilized.

(5) "Construction Permits"—Construction permits for on-site sewage management systems shall be issued in accordance with Section 290-5-26-.03(2)(a) of the Rules for OnSite Sewage Management Systems.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Subdivision and Mobile Home Parks" was filed on March 28, 1984; effective

April 27, 1984, as specified by the Agency. Amended:

ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER.

Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.15. Subdivision, Mobile Home Park Water and Sewage.

(1) "Subdivision and Mobile Home Park Water Supply"

(a) Connection to a public water supply system shall be required if available within 1,000 feet of the proposed subdivision or mobile home park.

(2) "Subdivision and Mobile Home Park Percolation Tests"—Where required for planning purposes and determination of the general absorptive capacity of soils, the number of percolation tests to be made shall be one

per lot, in the area where absorption fields are to be located. Before construction of onsite sewage management systems, individual lots within the proposed development shall

comply with Section 290-5-26-.14 of the Rules for On-Site Sewage Management Systems.

(3) "Subdivision and Mobile Home Park Test Bores" -Where required for planning purposes, test bores to determine groundwater elevations and subsurface rock formations shall be made at locations, in numbers and at depths to be determined by the department or county board of health.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Subdivision, Mobile Home Park Water and Sewage" was filed on March 28,

1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter

superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998;

eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.16. Technical Review Committee.

(1) "Technical Review Committee"—The department shall appoint and maintain a technical review committee consisting of a maximum of 15 individuals with technical or scientific knowledge relating to on-site sewage management systems. The duties of the committee will be to approve new systems,

periodically review systems performance, assist the department with the development of standards and guidelines for new technology,

assist with the periodic updating of the Manual for On-Site Sewage Management Systems, revisions to standards and serve as the authority for product approval, evaluation,

and the development of installation standards. The committee shall also maintain a list of approved systems.

(2) "Membership"—The committee shall include at least one individual from the following disciplines:

(a) An Environmental Health Section staff person who shall serve as the secretary;

(b) Local County Environmentalist;

(c) Health District Environmentalist;

(d) Engineering;

(e) Manufacturing;

(f) Home Builders Association;

(g) Soil Classifier;

(h) University/academia;

(i) District Health Director;

(j) Environmental Protection Division;

(k) Well Driller;

(l) Georgia On-Site Wastewater Association;

(m) Land Developer;

(n) Septic Tank Contractor.

(3) "Meetings"—The committee shall meet as deemed appropriate by the department.

(4) "Fee"—The department shall adopt a fee schedule for the technical review of new products and technology.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. Original Rule entitled "Enforcement" was filed on March 28, 1984; effective April 27, 1984, as specified by the Agency. Amended: ER. has been adopted. Filed Jan. 2, 1998; eff. Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject

matter superseding this ER. Amended: ER. repealed and permanent Rule, same title adopted. Filed Jan. 23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.17. Certification and Decertification of Septic Tank Contractors, Inspection Personnel, Pumpers, Soil Classifiers and Maintenance

Personnel.

(1) "Certification Required"—Individuals performing services related to site approval, the design, location, installation, inspection and maintenance of an on-site sewage management system, must be certified by the department.

(a) Guidelines defining certification qualifications for septic tank contractors, inspection personnel, pumpers, soil

classifiers and maintenance personnel shall be established by the department and shall be published in the Manual for On-Site Sewage Management Systems. The guidelines shall be based on education, experience,

testing and performance.

(b) The department shall write a protocol for decertification of persons certified under the provisions of this section.

(c) Certification shall be required every two years and shall be based on meeting continuing education requirements.

(2) "Fee"—The department shall adopt a fee schedule for the certification and recertification of the persons listed in this section.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. ER. has been adopted. Filed Jan. 2, 1998; eff.

Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended: ER. repealed and permanent Rule, entitled "Certification and Decertification of Septic Tank Contractors, Inspection Personnel, Pumpers, Soil Classifiers and Maintenance Personnel" adopted. Filed Jan.

23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.18. Maintenance and Operation.

(1) "Prohibited Discharge"—No person shall allow the unapproved discharge or spillage of sewage, nor shall an on-site sewage management system be used or maintained in such a manner that will allow the seepage or discharge of effluent from such system to the ground surface, to a water course, drainage

ditch, open trench, canal, storm drain or storm sewer, water well, abandoned well, lake, stream, river, estuary, groundwater, or other body of water.

(2) "Maintenance"—The property owner shall be responsible for properly operating and maintaining the on-site sewage management system to increase the life expectancy and prevent failure. Maintenance of the sys290-5-26-.16 LILBURN CODE tem shall be in accordance with the criteria

established in the department's current Manual for On-Site Sewage Management Systems. Where an on-site sewage management system is proposed to serve facilities under

separate ownership, a contract to insure proper operation and maintenance of the system signed by all owners, shall exist as a precondition to the issuance of a permit for the construction of an on-site sewage management system.

(3) "Additives"—No strong bases, acids or organic solvents shall be used in the operation of an on-site sewage management system.

(4) "Existing System Evaluations"—If a performance evaluation of an existing system is conducted, the evaluation shall be performed in accordance with the procedure established in the department's current Manual for On-Site Sewage Management Systems.

(5) "Variances"—The county board of health may grant variances in the cases of hardship where existing systems are malfunctioning.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. ER. has been adopted. Filed Jan. 2, 1998; eff.

Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule covering the same subject matter superseding this ER. Amended: ER. repealed and permanent Rule, entitled "Maintenance and Operation" adopted. Filed Jan.

23, 1998; eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.19. Enforcement.

The administration and enforcement of this chapter shall be in accordance with O.C.G.A. Chapter 31-5.

Authority O.C.G.A. §§ 12-8-1, 31-2-2, 31-2-4, 31-2-7.

History. ER. has been adopted. Filed Jan. 2, 1998; eff.

Jan. 15, 1998, as specified by the Agency, to be in effect for 120 days or until the effective date of a permanent Rule ER covering the same subject matter superseding this. Amended: ER. repealed and permanent Rule,

entitled "Enforcement" adopted. Filed Jan. 23, 1998;

eff. Feb. 20, 1998, as specified by the Agency.

290-5-26-.20. Standards for Non-Conventional On-Site Sewage Management Systems.

(A) The department shall review absorption field products that differ in design from the conventional on-site sewage management system. The following standards will be used to determine equivalency to the conventional on-site sewage management system.

1. The design infiltrative surface is the wetted trench bottom area.

2. Due to the combined effects of compaction, contact area and fines associated with gravel aggregate, the effective

infiltrative surface area is reduced by an estimated 50%.

3. The minimum amount of effective trench bottom infiltrative surface area per linear foot shall be equivalent to the conventional 36-inch wide gravel system.

4. Sidewall area shall not be considered for design reduction. The minimum amount of effective sidewall infiltrative surface area per linear foot shall be equivalent to the conventional 36-

inch wide gravel system.

5. The minimum storage volume required for a system shall be equivalent to the conventional 36-inch wide gravel system.

6. The design absorption area required is based on the most hydraulically limiting soil horizon that comes into contact with the infiltrative surface of the sidewall, trench bottom and for a distance one foot below the absorption trench bottom.

Infiltration area for conventional 36- inch wide gravel trench absorption Sidewall Infiltration Area: 2 sq. ft./ft × .50 = 1 sq.ft./linear foot Trench Bottom Infiltration Area: 3 sq.

ft./ft × .50 = 1.5 sq.ft./linear foot Storage Volume: 3 cubic feet/linear foot × 7.48 gallons/cubic foot × .35 =

7.85 gallons/linear foot

(B) Prior Approval: Lots approved for development based on a reduction in absorption trench length up to 50% shall continued to be

approved and permitted for up to a 50% reduction in absorption trench length provided the lot is part of a recorded plat or part of a preliminary development plan submitted

to the county board of health within one year of rule adoption. Preliminary plans must include as a minimum: proposed lots and streets with lot identifications, lot dimensions and square footage; a topographic map with water courses and flood plain identified;

a level 3 soil report; the location of the water supply system, right-of-ways, easements and utilities; and the name, registration number and seal of the professional surveyor or engineer.

Authority O.C.G.A. § 31-2-7. Adopted Jan. 21, 2004;

eff. March 1, 2004. Amended: Rule repealed and adopted April 27, 2005, effective June 27, 2005.

CHAPTER III. SWIMMING POOLS,

PUBLIC SPA POOLS AND

BATHHOUSES*

ARTICLE A. SWIMMING POOLS,

PUBLIC SPA POOLS, AND BATHHOUSES

Section 9-7001. Title and Purpose.

A regulation establishing minimum standards governing the use and maintenance of swimming pools, and structures; establishing

minimum standards governing supplied utilities and facilities and other physical things, and conditions essential to make swimming

pools and surrounding premises safe, sanitary and fit for human use; establishing minimum standards governing the condition and maintenance of swimming pools and structures; fixing certain responsibilities and duties of owners, operators and attendants of swimming pools; authorizing the inspection

of swimming pools and structures and providing for the condemnation of all swimming pools and structures deemed unfit for human

use.

This regulation upon adoption by the Board of Commissioners of Gwinnett County shall be known and may be cited as "The Gwinnett County Swimming Pool Ordinance."

Section 9-7002. Definitions.

The following definitions shall apply in the interpretation of these recommended standards:

• 2.1 SWIMMING POOL. Any structure of inert and enduring material such as concrete, masonry, metal, or other impervious material containing an artificial body of water for swimming, diving, or recreational bathing.

• 2.2 PUBLIC SWIMMING POOL. Any

swimming pool, other than a private residential swimming pool, for collective use by numbers of persons for swimming or bathing operated by any person as defined herein, whether he be owner,

operator, lessee, licensee, or concessionaire, regardless of whether a fee is charged, and all facilities incident thereto.

• 2.3 PRIVATE RESIDENTIAL SWIMMING POOL. Any swimming pool for a single family residence under the control of an individual homeowner, the use of which is limited to swimming or bathing by family members or their invited guests. Facilities serving 2—5 private

residences may upon application be considered as private under this regulation.

• 2.4 PERSON. Any individual, partnership, corporation, and association and may extend and be applied to bodies,

politic and corporate.

• 2.5 DESIGN PROFESSIONAL. An architect or engineer registered to practice in Georgia.

• 2.6 PRIME DESIGN PROFESSIONAL.

The design professional responsible for the entire project.

• 2.7 TURNOVER. The ratio of the volume of water circulated to the capacity of the pool.

Section 9-7003. General.

The provisions of this regulation are applicable to all swimming pools, both public, and residential as hereinafter designated, located

in Gwinnett County, Georgia, provided, however, that both public and private residential swimming pools in existence on the effective

date of these regulations, which have permits and are in compliance with the existing regulations, except in cases of major improvement and/or remodeling shall be approved under this regulation; and provided further

that swimming pools which serve a restricted clientele only, such as hotels, motels, apartments, and condominiums, shall not be required to meet the requirements hereof relating to telephones, showers, toilets, lavatory facilities and dressing rooms where such facilities are readily available in near or close by structures to all persons who may use the

swimming pool.

3.1 Permits: (Public): It shall be a violation of this regulation for any person to operate a public swimming pool in Gwinnett County, Georgia, who does not possess an unrevoked operating permit from the Director, Gwinnett County Board of Health. Such permit shall be displayed at all times in a place

designated by the Director, Gwinnett County Board of Health. Only persons who comply with all the requirements of this regulation shall be entitled to receive and retain such a permit. Such a permit may be

temporarily suspended by the Director, Gwinnett County Board of Health upon the violation by the holder of any of the terms of this regulation; or revoked after an opportunity for a hearing by the Director, Gwinnett County Board of Health upon serious or repeated violation. Before a pool

permit is granted pursuant to this chapter by the health authority, each applicant shall pay fees in the amounts established by action of the county board of health and county board of commissioners. Permit holders who fail to submit any fee by the date required, are subject to permit suspension

and administrative closure of the pool. It is the responsibility of an individual or organization, which becomes the owner of a pool to notify the health authority immediately. The permit is non-transferable between individuals or organizations. A change of ownership invalidates the permit. Additional fees as per the amounts established by action of the county board of health and

county board of commissioners shall be charged for operating a pool without a valid permit.

3.2 Inspection of Swimming Pools (Public):

Periodically, the Director, Gwinnett County Board of Health, or his/her duly appointed representative shall inspect every operating swimming pool located within Gwinnett County, Georgia. The operational permit may be immediately suspended when a condition is present, which in the judgment of the health authority is an imminent health hazard to the public or is a violation of included safety measures as

approved by the Gwinnett County Board of Commissioners, including but not limited to the following:

1. Low or no chorine, bromine, or other health authority approved sanitizer.

2. pH outside of established range.

3. Glass or other cutting hazards in the pool.

4. The filtration pump being nonoperational.

5. The filter being non-operational.

6. The chlorinator/automated sanitizer delivery system being nonoperational.

7. A section of a required safety barrier being missing.

8. A gate or door into the pool enclosure unable to be securely latched

9. A main drain grate being missing, loose, or broken.

10. A pool operating with a single main drain/suction outlet grate which is not a health authority approved safety cover.

Reinstatement of a previously suspended permit shall occur after a re-inspection is performed. Said re-inspection must demonstrate the violation(s) which led to the permit suspension have been corrected. It

shall be a violation of this regulation to operate a pool without a valid permit.

Before a re-inspection shall be performed a fee shall be paid to the health authority in the amount established by action of the county board of health and county board of commissioners. A re-inspection may be performed, at the discretion of health authority, due to any violation.

Section 9-7004. Plans and Specifications.

Plans and specifications for proposed new swimming pools or for substantial alterations or reconstruction of existing pools: public swimming pools plans and specifications shall be prepared by design professionals and bear the registration of the design professional.

4.1 The plans shall be drawn to scale and shall be accompanied by complete specifications so as to permit a comprehensive review of the plans including the piping

and hydraulic details and shall include:

1. A plan and sectional view with all the necessary dimensions of both the pool and surrounding areas.

2. Complete site drainage details including diversion ditches for surface run-off.

3. A piping diagram showing all appurtenances, including treatment facilities in sufficient detail, as

well as pertinent elevation data, to permit a hydraulic analysis of the system.

4. Specifications shall contain details of all treatment equipment, including performance characteristics of pumps, chlorinators, chemical feeders, filters, strainers, interceptors and related equipment.

4.2 All public swimming pools shall be provided with a recirculation and filtration system except when there is a flow of water of such quality and quantity through the pool that the pool water will at all times conform to the water quality standards set forth in paragraph 28.4 and 28.5.

Section 9-7005. Water Supply.

The water supply for all pools, showers, lavatories, drinking fountains, and any other uses in conjunction with the pool shall be adequate in quantity and shall comply with all requirements of the Georgia Safe Drinking Water Act of 1977 and the Rules and Regulations promulgated by the Department

of Natural Resources.

5.1 The water distribution system serving the swimming pool shall be protected against backflow by means of an air gap, not less than two service pipe diameters in width, between the service pipe and the flood rim of the receiving vessel, or backflow prevention device approved by Gwinnett County Planning & Development Department and the Director, Gwinnett County Board of Health or his designated representative.

Section 9-7006. Structure Design and Materials.

Swimming Pools shall be designed and constructed to withstand all structural stresses including external hydrostatic pressures and flotation.

6.1 Public swimming pools shall be constructed of inert and enduring materials, non-toxic to man, which will provide a

smooth and easily cleanable surface with no cracks or open joints, and shall be finished in a light color. Interior corners shall be coved with a minimum radius of six inches.

Section 9-7007. Shape, Slope, and Depth (Public Pools).

The pool shall be designed and constructed so that efficient and safe control of the pool and bathers can be accomplished. For water depth less than five feet the slope of the pool bottom shall be uniform and shall not exceed one foot of slope in 12 feet. For depths greater than five feet, the slope shall not exceed one foot in three feet.

7.1 The maximum depth at the shallow end of the pool shall not exceed three feet six inches except for competitive or special purpose pools.

7.2 The minimum depth of water in the pool shall be three feet except for special instructional pools or for restricted or recessed areas in general pools which are set aside primarily for the use of children.

Such areas when included as part of the pool shall be separated from the pool proper by means of a safety line supported by buoys and attached to the side walls.

7.3 The depth of the water at the deepest point, at the shallow end, and at slope break in the pool bottom between the shallow and deep portions of the pool, shall be permanently and conspicuously marked

above water at pool sides and deck. Markers shall be visible at night under artificial illumination where night swimming is permitted.

7.4 Walls of a pool shall be either (a) vertical for water depths of at least six feet, or (b) vertical for a distance of two feet six inches below the water level, below which the wall may be curved to the bottom with a radius equal to the difference between the depth and two feet six inches.

Section 9-7008. Inlets and Outlets (Public Pools).

Inlets and outlets to pools shall be arranged so as to get effective and uniform circulation of the incoming water throughout

the pool.

8.1 A sufficient number of inlets shall be provided to obtain adequate circulation and prevent dead spots. A maximum spacing of 20 feet shall be provided between inlets.

8.2 Maximum flow rates (in gpm) through various fixed inlet branches shall be not more than as listed below:

Maximum Flow Rates Size 1" 11 /4"11 /2" 2"

GPM 10 20 30 50

8.3 All inlets shall be designed as adjustable orifices, or shall be individually valved, and shall be submerged not less than 24"

below overflow level to reduce the escape of disinfecting agents. Inlets shall be flush with the pool wall. Proprietary inlet systems that are part of a gutter or skimmer system and do not meet all of the above

inlet requirements, may be considered to meet the requirements of this regulation if the inlet system meets the intent of the above requirements, has been proven to operate satisfactorily, and/or acceptable to the Director, Gwinnett County Board of Health or his representative.

8.4 Two or more outlets shall be provided at the deepest point of the pool to permit the pool to be completely drained. Each low point in the pool shall be adequately served by an outlet. Beginning May 1st, 2010, all pools must have multiple main drains, which are connected by a tee piping configuration under the pool, or a single main drain which is unblockable. An unblockable drain grate cover is hereby defined as having a horizontal measurement of at

least 29 inches. Any circulation or water feature pump must be supplied water by multiple main drains or a single main drain with an unblockable drain grate cover.

The term water features includes but is not limited to water slides, lazy rivers, therapy jets, mushrooms, and water cannons.

8.5 Outlets shall be spaced not more than 30 feet apart and not more than 15 feet from the side walls. All main drain covers, for circulation and water features, shall be maintained in an unbroken and fully attached condition.

8.6 The area of all outlet openings shall be covered with gratings or other coverings which are not readily removable by bathers.

8.7 Net openings in each floor outlet covering or grating shall be at least (4) four times the area of the discharge pipe or

shall provide sufficient area so that the maximum velocity of the water passing the grate will not exceed 1.5 feet per second.

The width of openings in grating shall be not less and [than] 1 /2-inch and not more than one inch.

8.8 Outlets shall not connect directly to sewers but shall be installed in such manner that any sewage backing up from the sewer will overflow to waste and cannot

reach the pool. Pool drainage, valves and pumps shall be sized to prevent surcharge of the sanitary sewer.

Section 9-7009. Overflow Facilities (Public Pools).

Positive means shall be provided for continuous removal of scum, sputum and floating debris from the pool surface. Drainage from overflow facilities shall be discharged to

waste or to a make-up or surge tank.

9.1 Overflow gutters where used shall meet the following standards:

1. Overflow gutters shall extend completely around the swimming pool except at steps or recessed ladders. The lip of the gutter shall be level and shall be designed to

serve as a handhold for bathers.

2. Overflow gutters shall be smooth finished and of open, roll-over or semi-recessed type, except overflow gutters for water-level deck type public swimming pools may

be countersunk in a deck sloped to drain from the gutter and such gutters shall be covered by a flush mounted grating.

3. Overflow gutters shall be designed to permit ready and effective cleaning and to prevent accidental entrapment of bather's arms or legs.

4. Overflow gutter and outlet design shall provide for continuous removal of not less than 50% of

the re-circulated water for return to the filter or to waste.

5. Overflow gutters shall be provided with drainage outlets of two inches minimum diameter at

intervals of not more than 15 feet. Outlets shall be covered by removable gratings.

9.2 Skimmers where used shall comply in all respects with appropriate standards of the National Sanitation Foundation regarding materials, design, operation and safety and shall meet the following standards:

1. Skimmers may be used in lieu of overflow gutters provided the circulation system is designed to produce substantial circulatory

movement to pool water for promotion of skimming and of uniform disinfectant distribution and provided a handhold equivalent

to bullnose coping with outer two inches not over two and one-half inches thick is extended around the pool perimeter not more than nine inches above the normal water level.

2. Skimmers shall be designed for a flow through rate of at least 30 gallons per minute and the total capacity of all skimmers in any pool shall be at least 80 percent of the required filter flow of the recirculation system. Each skimmer shall be provided with a valve for equalization of flow.

3. Skimmers shall be built into the pool wall and the weir shall be automatically adjustable to water level variations over a range of at least four inches. At least

one skimmer shall be located to oppose the prevailing wind.

4. Skimmers shall be designed and located to effectively remove floating materials from the water surface of the entire pool area. At least one skimmer shall be provided for each 500 square feet of water surface area or fraction

thereof.

5. Skimmers shall be provided with an easily removable and cleanable screen or basket to trap large solids.

6. Skimmers shall be designed or equipped to prevent air lock in the suction line. Equalizer lines, if used, shall be sized to meet capacity requirements of the filter and pump and in no case shall be less than two inches in diameter. Equalizer lines shall be installed at least one foot below the lowest weir level and equipped

with values or devices to remain closed at normal operating conditions but automatically open when water level drops two inches below the lowest weir level.

Section 9-7010. Hose and Connections (Public Pools).

Sufficient hose connections, at least 3 /4- inch diameter, shall be provided for cleaning the pool, decks, walks, toilets, dressing rooms and other flooded areas used in connection with pools and bathhouses. Hose connections shall be fitted with an approved vacuum breaker.

Section 9-7011. Steps, Ladders, and Handrails.

Steps or ladders shall be provided at the shallow end of pools where the vertical distance from pool bottom to deck level is over two feet. Recessed steps or ladders shall be

provided at the deep portion of the pool and if the pool is over 30 feet wide, such steps or ladders shall be installed on each side. A means of egress shall be provided for each 75 feet of pool perimeter.

11.1 Steps shall be of non-slip design with minimum tread of 12 inches and maximum rise of 12 inches. Abrupt drops or submerged projections into the pool shall be guarded by handrails.

11.2 Ladders shall be corrosion-resistant and shall be equipped with non-slip treads.

They shall be designed to provide a hand hold and shall be rigidly installed with clearance between the ladder and the pool wall not less than three inches nor more than six inches.

11.3 Steps inserted in the pool wall shall be of easily cleanable construction, designed to drain into the pool, and shall be at least 14 inches wide and five inches deep and a maximum of 12 inches vertical spacing.

11.4 Ladders within the swimming pool shall be equipped with a handrail at the top of both sides thereof, extending not less than 30 inches above the coping or edge of the deck.

Section 9-7012. Wading Pools (Public Pools).

Wading pools for non-swimming children may be independent auxiliary pools or may be restricted areas of a general swimming pool. All applicable sections of this standard shall apply to wading pools.

12.1 Restricted areas of swimming pools set aside for use as wading pools shall be separated from the main body of the pool by means of a safety line attached to the side walls and supported by buoys. This restricted area of the swimming pool shall have a turnover rate of once every two hours or less with inlets and outlets and overflow facilities sized accordingly.

12.2 Independent wading pools shall have maximum depth of not more than 18 inches;

the bottom shall be non-abrasive, shall have a non-slip finish and shall be sloped toward a drain at not more than three inches in ten feet nor less than one inch in ten feet. Such wading pools shall be served by a swimming pool recirculation system with turnover rates of once every two hours or less.

Section 9-7013. Spray Pools (Public Pools).

Spray pools are small independent artificial pools for non-swimming children into which water if sprayed but is not allowed to

pond. Spray pools may be supplied by the swimming pool recirculation system or by water meeting the same quality requirements from other sources with all drainage to waste. All applicable sections of this standard shall apply to spray pools.

13.1 Spray pool bottoms shall be nonabrasive, shall have a non-slip finish, and shall be sloped toward a drain at not more

than three inches in ten feet nor less than one inch in ten feet.

Section 9-7014. Deck Areas (Public Pools Except 14.3 Applies To All).

A clear and unobstructed paved deck or walkway shall extend completely around the pool; deck width shall be at least five feet measured from the pool side edge, except at the deep end where there is a diving board and width shall be at least ten feet.

14.1 Deck drainage shall be conducted away from the pool area and shall be pitched to drains designed to conduct drainage from the pool to points of disposal in a manner that will not create unsanitary,

hazardous, or objectionable conditions. Deck shall be sloped no less than 1 /4-inch per foot.

14.2 Decks shall have a non-slip surface and shall be of a material and finish that can be cleaned by hosing.

14.3 An effective fence or barrier, not less than four feet high, shall be provided on the outer side of the walk area to prevent spectators in street attire from traversing the pool walk and prohibit access of unattended children and animals to the pool. A barrier shall not be required around a

spray pool, with no standing water. There shall be no more than four inches of clearance between the bottom of the fence barrier and ground surface or pool deck. Any gate(s) shall be located at the shallow end

of the pool and shall be self-closing and have a lockable self-latching device. Where pools serve special purposes, as therapeutic pools, waiver of this requirement may be acceptable.

Section 9-7015. Diving Areas and Equipment (Public Pools).

The dimensions of the swimming pool in the diving area shall conform to Figure No. 1.

Board Height Over Water Minimum Dimensions

D1 D2 L1 L2 L3

26" (2 /3 meter) 7'0" 8'-6" 2'6" 8'-0" 10'6" 30" (3 /4 meter) 7'6" 9'-0" 3'0" 9'-0" 12'-0" 1 meter 8'-6" 10'-0" 4'-0" 10'-0" 15'-0" 3 meter 11'-0" 12'-0" 6'-0" 10'-6" 21'-0" NOTE: Placement of boards shall observe the following minimum dimensions. With multiple board installations minimum pool widths must be increased accordingly.

1 Meter or Deck Level Board to Pool Side 9' (2.74m) 3 Meter Board to Pool Side 11' (3.35m)

1 Meter or Deck Level Board to 3 Meter Board 10' (3.05m) 1 Meter or Deck Level to another 1 Meter or Deck Level Board 8' (2.44m) 3 Meter to Another 3 Meter Board 10' (3.05m)

15.1 At least 15 feet of free and unobstructed head room shall be provided above diving boards.

15.2 Diving board steps and ladders shall be of corrosion-resistant material, easily cleanable and of non-slip design, and kept in good repair. Handrails shall be provided at all steps and ladders leading to diving boards with elevations one meter or more above the water. Platforms and diving boards which are one meter or more high shall be protected with guard railings.

Section 9-7016. Electrical.

All electrical materials and workmanship shall be in compliance with the Gwinnett County Construction Code and current adopted edition of the National Electrical Code.

16.1 In all installations to be used at night, pools, deck areas, dressing rooms, toilets, Figure No. 1 equipment rooms, chemical rooms, and concessions shall be lighted in accordance with the following minimum standards:

1. Under Water Lighting:

• Indoor: 100 lamp lumens/ square foot of pool surface.

• Outdoor: 60 lamp lumens/ square foot of pool surface.

2. Deck Lighting—Foot candles maintained in service: (Public only) Outdoor Indoor Exhibition 20 F.C. 50 F.C.

Recreation 10 F.C. 30 F.C.

Minimum Mounting Height 30 Feet 20 Feet

3. Lighting in dressing rooms, toilet, equipment rooms, chemical rooms, concessions, and related

areas shall be in compliance with the above reference codes.

16.2 Switches, starters, panel boards and similar electrical equipment shall be located in areas not readily accessible to bathers.

16.3 Each underwater light shall be individually grounded.

16.4 No overhead electrical wiring shall pass within 20 feet of the swimming pool enclosure.

Section 9-7017. Recirculation and Filtration System.

The entire recirculation and filtration system shall be designed for continuous operation and shall have sufficient capacity to clarify the entire pool volume in eight hours

or less thus providing at least three turnovers daily. Where separate wading pools are provided for children, recirculation capacity

shall provide for complete turnover of the wading pool content every two hours or less.

Comment—The pool turnover rate of eight hours will provide satisfactory water quality under "normal" conditions. Turnover rates of less than eight hours should be considered when the maximum patron load can be expected for extended periods and/or the environmental conditions (temperature, sunshine, debris, wind, etc.) are expected to be extreme.

17.1 A rate-of-flow indicator, reading in gallons per minute, and a flow regulating valve shall be installed and located so that the rate of recirculation and backwash rate will be indicated and can be controlled.

17.2 All recirculation and filtration equipment that requires adjustment and maintenance, and sight-glasses, dials or meters that must be recorded shall be readily

accessible and have unobstructed clearance from walls, ceiling, and other equipment, and shall be well lighted.

17.3 Swimming pool heaters when used shall be certified by a nationally recognized organization and shall be in compliance with the Gwinnett County Gas & Electrical Codes.

Section 9-7018. Pumping Equipment.

Pumps and motors shall have sufficient capacity to provide the required number of turnovers specified in Section 9-7017 above and for providing adequate flow and head to backwash filters at rates set forth below.

18.1 Recirculation pumps shall be located below the pool water level to provide positive pressure on the suction side, or positive priming method shall be provided. A check valve shall be installed on the pump

discharge line.

18.2 Requirements for filtration shall be based upon the maximum head loss developed immediately prior to backwashing the filters. Comment—Additional head of

5%—10% should be added for pump ware, piping changes, etc. (safety factor).

Section 9-7019. Hair and Lint Strainer (Public Pools).

A strainer shall be provided on the suction side of the pump to prevent hair, lint, and other matter from reaching the pump and filters. Strainers shall be corrosion resistant with openings not over 1 /8 width in size providing a free flow area at least four times the area of the pump suction line and shall be

readily accessible for frequent cleaning.

Section 9-7020. Suction Cleaner (Public Pools).

A suction cleaner, either built in or portable type, shall be provided for removing sediment from the pool floor and shall be capable of reaching all parts of the pool floor. Built-in

cleaners shall provide sufficient connections in the pool walls at least eight inches below the water line. Portable or jet-type units shall be provided with backflow protection for the water system.

Section 9-7021. Piping.

Pool piping shall be detailed on the plans as to size and material. Buried flexible plastic pipe shall not be used. Piping shall be of non-toxic material, resistant to corrosion, and

able to withstand operating pressures. Plastic pipe, when used shall be NSF approved.

Piping shall be in compliance with the Georgia State Plumbing Code.

21.1 Piping shall be designed to carry the required quantity of water at a maximum velocity not to exceed six feet per second on piping to the suction side of the recirculation pump and not to exceed ten feet per second in discharge lines.

21.2 Piping shall be positively supported to prevent settlement which may cause air pockets or sediment traps or rupture of lines. Piping shall be provided with uniform slope and with positive means of draining water to prevent damage from

freezing.

21.3 Valves shall be provided to cut off flow during cleaning or inspection of strainers and pumps.

Section 9-7022. Disinfectant Feeders (Public Pools).

All pools must have a chlorinator/automated disinfectant feeder system. Equipment and piping used to apply disinfectant chemicals to the water shall be of such size,

design and material that they may be cleaned.

Feeders shall not be cross-connected with potable water systems. Materials used for such equipment and piping shall be resistant to the action of chemicals to be used therein.

22.1 A means of disinfecting the pool water which provides a residual agent in the pool water shall be used. The disinfecting agent shall be subject to simple field tests for determination of concentration. Chlorinators or other disinfectant feeders shall be capable of supplying at least the equivalent of one pound of available chlorine per eight hours per 10,000 gallons of pool capacity; rate of feed shall be adjustable and shall be indicated on the feeder.

22.2 Chlorinators or other disinfectant feeders shall be of sturdy construction and materials which will withstand wear, corrosion or attack by disinfectant solutions or vapors and which are not adversely

affected by repeated adjustments or other conditions anticipated in the use of the device. The feeder shall be easily disassembled for cleaning and maintenance and shall be designed and constructed to minimize stoppage from chemicals used. Feeder design shall include fail-safe features to

prevent the disinfectant feeding directly to the pool or its components under any type of failures of equipment or maintenance.

22.3 Disinfectant feeders shall have a graduated and clearly marked dosage adjustment to provide flows from full capacity to 10% of such capacity. The device shall be

capable of continuous delivery within 10% of the dosage at any setting.

22.4 When the disinfectant is introduced at the suction side of the pump, a device shall be provided to prevent air lock of the pump or recirculation system.

22.5 When chlorine gas is used the following additional features shall be provided:

1. The chlorine and chlorinating equipment including scales and

(1) one extra chlorine cylinder, shall be in a separate well-ventilated room. Floors of such rooms shall not be below ground level.

The room shall be provided with an exhaust fan located at floor level and vented to the out-ofdoors. Exhaust fan shall produce a complete exchange of air in two

minutes. Louvers shall be provided at the top of the room on the wall opposite the exhaust fan

for admitting fresh air. The room shall be sealed (air tight) from adjacent rooms to prevent chlorine gas circulation.

2. The door of the chlorine and chlorinating equipment room shall not open to the swimming pool or

filter room and shall open to the out-of-doors. A viewing window and exterior-controlled artificial illumination and exhaust fan shall be provided so that essential performance of the equipment may be observed without/before entering the room.

3. Facilities shall be provided for anchoring chlorine cylinders to a wall or other support to prevent their falling over.

4. The chlorinator shall be a solution feed type, capable of delivering chlorine at its maximum rate without releasing chlorine gas to

the atmosphere.

5. The chlorinator shall be designed to prevent the backflow of water into the chlorine solution container. All piping containing chlorine gas either under pressure or under vacuum shall be located in

chlorine equipment room.

6. A closed gas mask cabinet, accessible without a key shall be located outside of the chlorinator room. The cabinet shall be

equipped with a gas mask designed for use in a chlorine atmosphere and of a type approved by the U.S. Bureau of Mines.

7. Installation of chlorinator equipment, and initial operation thereof, shall be under the supervision of personnel experienced with the installation and operation of such equipment.

22.6 When a hypochlorite solution is to be fed through hypochlorinator equipment, such equipment shall also provide the following additional features.

1. Feed shall be positive under all conditions of pressure in the circulation system.

2. A method shall be provided for reducing to a minimum the entry into a swimming pool of free calcium released from calcium hypochlorite.

3. A method shall be provided to prevent siphoning of hypochlorite solution when the recirculation pump and hypochlorinator are both turned off.

Section 9-7023. Filtration Equipment (Public Pools).

Filter shall be capable of maintaining water in the pool which meets physical standards set forth in Section 9-7023 herein.

Sufficient filtering area shall be provided to meet the design pump capacity as required by Section 9-7023 herein. Filters shall comply in all respects with appropriate standards of the National Sanitation Foundation regarding materials, design, operation and

safety.

23.1 A sight glass shall be installed on the waste discharge line of pressure filters to observe the progress of filter washing. The filter system shall be provided with influent and effluent pressure, vacuum or compound gauges shall be provided with shutoff cocks. Air-relief valves shall be provided at the high point of the filter. In vacuum

filter installations where the circulating pump is two horse-power or higher an adjustable high vacuum shut-off shall be provided to prevent damage to the pump by cavitation.

23.2 Rapid sand filters shall be designed for a filter rate to the swimming pool of not more than three gallons per minute per square foot of bed area at a time of maximum headloss with sufficient area to meet the design rate of flow required by the

prescribed turnover.

1. For standard underdrain systems not less than 20 inches of screened sharp filter sand with

effective size between 0.4 and 0.55 mm., and a uniformity coefficient not exceeding 1.75 supported by at least ten inches of graded filter gravel shall be provided. A reduction in this depth or elimination of gravel may be permitted where

equivalent performance and service are demonstrated.

2. At least 12 inches of freeboard shall be provided between the upper sand surface and the backwash overflow invert.

3. Each pressure filter unit shall be provided with an access opening of not less than a standard 11 inches × 15 inches manhold and cover.

4. Facilities shall be provided for adding chemicals for coagulation and pH control.

5. Filter piping shall be designed and valved to permit individual backwashing of filters to waste at not less than 15 gallons per minute per square foot of filter area, to permit isolation of individual

filters for repairs while keeping others in service to permit complete drainage, and to permit maintenance, operation and inspection in a convenient manner.

6. Sampling cocks shall be provided to enable sample collection of pool water as it leaves the pool and as it leaves the filters.

23.3 Diatomaceous earth filters shall be designed for a filter rate to the swimming pool of not more than 2.0 gallons per minute per square foot of effective filtering surface without continuous body feed and

not greater than 2.5 gallons per minute per square foot with continuous body feed.

1. Appurtenances shall be provided for precoating with diatomaceous earth slurry. Provisions for recirculating during the precoating operation shall be made where filters permit passage of earth through elements during precoating operations. Sight glass will be required for pressure filters.

2. Where body feed is provided, the device shall be accurate (±10%) and shall be capable of continually feeding within a calibrated range, adjustable from two to six

ppm, at the design capacity of the recirculating pump.

3. Filtering area, where fabric is used, shall be determined on the basis of effective filtering surfaces as created by the septum supports with no allowances for

areas of impaired filtration, such as broad supports, folds, or portions which may bridge.

4. Filters shall be equipped for cleaning by one or more of the following methods: back-washing, airbump-assist backwashing, spray wash (mechanical or manual), or

agitation.

5. Provision shall be made for completely and rapidly draining the filter.

23.4 High rate sand filters shall be designed for a filter rate to the swimming pool of not more than 20 gallons per minute per square foot of filtering surface shall meet the standards set forth in items 23.1

and 23.2 herein.

23.5 Cartridge filters shall be designed for filter rate to the swimming pool of not more than 0.33 gallons per minute per square foot of effective filter area.

1. Filter(s) shall be equipped with at least influent and effluent pressure gauges with gauge cocks and an air-relief valve.

2. Two sets of filter cartridges shall be provided to facilitate cleaning and drying of one set while the other is in operation. Disposable cartridges shall be replaced when initial filtration rate is impaired by clogging.

Section 9-7024. Make-up Water Facilities (Public Pools).

All pools shall be equipped with provisions for adding make-up water to compensate for water loss through evaporation and to waste so that a constant water level is maintained while the pool is in operation to enable continuous flow into skimmers or overflow gutters.

Section 9-7025. Bathhouses (Public Pools).

Bathhouses containing dressing rooms, showers, toilets, and lavatories shall be required for public swimming pools. Bathhouses shall be in compliance with Gwinnett County Building, Plumbing, Mechanical, Gas,

and Electrical codes.

25.1 Bathhouse facilities may not be required for swimming pools located on premises of motels, hotels, or other transient residences, and apartment complexes where

such facilities are available in adjacent structures and the swimming pool use is restricted to the employees, occupants, and guests of such establishments. The governing authority shall determine any bathhouse requirements for such establishments. Comment—Consideration by the governing authority should be given to:

distance to adjacent structures, bather load estimates, operator control, and health matters when evaluating bathhouse requirements for these potentially exempt establishments.

25.2 Bathhouses may also contain public areas, manager's area, first-aid room, and like areas.

25.3 Where bathhouses are used by both sexes at the same time, separate and clearly labeled dressing rooms separated by a tight partition shall be provided for each sex;

entrances and exits shall be screened to break the line of sight.

Section 9-7026. Bathhouse Facilities (Public Pools).

26.1 Dressing room floors shall be easily cleanable, non-slip finish, impervious to moisture and sloped to drain. Walls and partitions shall be of easily cleanable construction and junctions of walls and floors shall be coved.

26.2 Dressing rooms, toilet rooms, shower rooms, shall be ventilated by natural or artificial means to effectively eliminate odors and condensation.

26.3 Shower, toilet and lavatory facilities shall be provided in accordance with the following schedule and shall be based on pool capacity computations set forth in Section 9.7027 herein, or on scheduled use periods as at schools. Showers shall not be required to be provided for patrons of a spray pool, with no standing water:

Fixture Males Females Water Closets 1/60 1/40 Urinals 1/60 NA Lavatories 1/60 1/60 Showers (minimum of 3 each side) 1/40 1/40 Drinking Fountain. Minimum of one to be located in swimming pool area. Hose bib with vacuum breaker required in each toilet room as a minimum.

26.4 Toilet and shower room floors shall be constructed of impervious materials with no open cracks or joints, have an easily cleanable, non-slip finish and shall pitch toward a drain. Juncture of walls and floors shall be coved.

26.5 The location of dressing rooms shall be arranged so that bathers leaving a dressing room must pass the toilets and showers en route to the swimming pool.

26.6 Showers and lavatories shall be supplied with warm water at a temperature of 90 degrees to 110 degrees F from a single

source. Hot water temperature control devices shall not be available to patrons.

26.7 Any food service facilities associated with the bathhouse or swimming pool must meet the requirements of the Gwinnett County Board of Health Rules and Regulations for Food Service.

Section 9-7027. User Load Computation.

In computing user loading, those portions of the swimming pool five feet or less in depth shall designated as "non-swimmer" areas and those portions over five feet in depth shall be designated as "swimmer" areas.

27.1 To compute the in pool swimmer and bather capacity, swimming pool areas shall be determined as follows:

1. Ten square feet of pool water surface area shall be provided for each non-swimmer expected at

time of maximum load.

2. Twenty-four square feet shall be provided for each swimmer expected at time of maximum load.

3. Three hundred square feet of pool water surface area shall be reserved around each diving board or diving platform and this area

shall not be included in computing the area of the swimming section. During the preliminary

design phase of a swimming pool facility, the owner (operator), prime design professional, and the governing authority should agree on pool and deck capacities, depending on the establishment or area served. In general, the experience and knowledge of

the area by the governing authority should be the prime factors in capacity determinations.

Section 9-7028. Disinfection and Water Quality (Public Pools).

The chemical, physical, and bacteriological quality of pool water shall be such that it is sanitary, clear, and safe for swimming.

28.1 Swimming pools when open or in use shall be continuously disinfected by a chemical which imparts an easily measured free available residual effect. The minimum

free available chlorine level shall be 1.0 ppm. If the cynanuric acid level is 50 ppm or higher, the minimum free available chorine level shall be 1.5 ppm. The cyanurate level shall not be greater that 100 ppm. A testing kit for measuring the concentration of cyanuric acid, accurate within 5.0 ppm, shall be provided at each swimming pool using cyanuric acid or chlorinated cyanurates.

28.2 Other disinfecting materials or methods shall be acceptable satisfactory residual effect which is easily measured and to otherwise be equally as effective under

conditions after they have been adequately demonstrated to provide a of use as the chlorine concentration required herein, and not be dangerous to public health, create objectionable physiological effect, or impart toxic properties to the water.

28.3 The swimming pool water shall be maintained in an alkaline condition as indicated by a pH of not less than 7.2 and not over 7.8.A pH testing kit accurate within 0.2 pH unit shall be provided at each swimming pool. A total alkalinity of the water shall be at least 80 ppm.

28.4 The water shall be of sufficient clarity, so as the main drain covers shall be clearly visible.

28.5 Not more than 15% of the samples covering any considerable period of time shall either (a) contain more than 200 bacteria per milliliter, as determined by the standard (35 degrees C), agar plate count, or (b) show positive test (confirmed test) for coliform organisms in any of the five 10 milliliter portions of a sample or more than 1.0 coliform organism per 50 ml.

when the membrane filter test is used. All samples shall be collected, dechlorinated, and examined in accordance with the procedures outlines in the latest edition of Standard Methods for the Examination of

Water and Wastewater (APHA).

28.6 Chemicals used for algae control and in the control of water quality shall be registered by the Federal Environmental Protection Agency as applicable and used in accordance with label directions.

Section 9-7029. Operation and Maintenance (Public Pools).

A pool operator, with a certification approved by the health authority, shall be employed or contracted by the pool owner. An emergency contact phone number, of a person

responsible for the pool, must be posted in clear public view on the exterior of at least one of the pool enclosure entrances. Pool owners shall be responsible to notify the health authority immediately upon learning of a fecal, vomit, or blood accident in the pool.

Pool owners shall be responsible to follow all the current recommendations of the Centers for Disease Control and Prevention for responding to fecal, vomit, or blood accidents in pools.

29.1 The operator of each pool open for use shall keep daily records of pool operations including total bather load, peak bather load, volume of fresh water, filter influent and effluent pressure gauge readings, rate of flow meter readings, amount of chemical used, disinfectant residuals, pH readings, algae control measures taken, alkalinity, maintenance and malfunctioning of equipment including cleaning of filters, and such additional records as may be required.

Such records shall be kept available for inspection by the board of health for a period of at least one year.

29.2 Routine daily and weekly operating procedures shall be posted in a location frequented by the operator. Manufacturer's instructions for operation and maintenance of mechanical and electrical equipment shall be kept on the premises and available for the operators use.

29.3 Pumps, filters, disinfectant and chemical feeders, flow indicators, gauges, and all related parts of the pool water purification system shall be kept in operation whenever the pool is available for use, and

at such additional periods as may be necessary to maintain the water in the pool in a clear and disinfected condition.

29.4 Floating scum, sputum and debris shall not be allowed to accumulate in the pool. The sides and bottom of pools, decks, and other surfaces shall be kept free of slime and algae to prevent unnecessary slipperiness and danger of accident or drowning, and shall be cleaned as often as necessary to keep in a clean condition.

29.5 Where chlorine gas is used, a valve protection hood shall be kept in place on the cylinder except when the cylinder is connected to a chlorinator. A valve stem wrench shall be maintained on chlorine cylinders connected to chlorinators so that the supply can be shut off quickly in emergencies.

29.6 Replacement canisters for the chlorine gas mask shall be provided and a record kept of all gas mask usage to insure

that the mask will be serviceable when needed. The gas mask, replacement canisters, and record usage shall be kept in a closed container located outside the chlorinator room.

29.7 Dressing rooms, showers, toilet rooms and fixtures, equipment rooms and equipment, concession and spectator areas, and all parts of the pool enclosure shall be kept

clean in good repair. Walls, ceilings and equipment shall be painted as often as necessary to minimize deterioration. The entire pool area shall be maintained in a sanitary condition and free of litter and vermin.

29.8 Soap shall be provided at showers and lavatories.

29.9 Bathing suits and towels provided by the pool management shall be laundered and sanitized after each use.

Section 9-7030. Bather Supervision (Public Pools).

30.1 At any time a lifeguard, certified by Red Cross or other health authority approved organization, is not present at an open pool, a sign stating "No Lifeguard on

Duty" shall be posted in clear public view except at spray pools, with no standing water.

30.2 Visitors and spectators shall be kept separated from spaces used by bathers.

30.3 No food, drink, bottles or wrappers shall be permitted in the immediate area of the swimming pool or on the decks surrounding the pool.

30.4 Bathers shall take a cleaning shower, using warm water and soap, before entering the pool and before returning to the pool following use of the toilet.

30.5 Persons having an infectious or communicable disease, which can be transmitted by water, shall be excluded from public swimming pools. Persons with open blisters or cuts shall be warned of infection and advised not to use the pool.

30.6 No running, boisterous or rough play, except water sports, shall be permitted in the pool enclosures, dressing rooms, shower rooms, or other areas.

30.7 Spitting, spouting of water, blowing the nose, etc., in the swimming pool shall be strictly prohibited.

30.8 Suitable placards embodying provisions of this section shall be conspicuously posted in the swimming pool room or enclosure and in the dressing rooms and offices at all swimming pools. Placards

shall also state the maximum user loads in the various areas of the swimming pool facility Section 9-7031. Safety Precautions (Public Pools).

Life saving and emergency first aid equipment and facilities shall be provided at all swimming pools. A telephone and list of emergency numbers including physician, ambulance and hospital should be provided.

31.1 A life line shall be provided at or near the break of grade between the shallow and deep portions of a public swimming pool with it position marked with colored floats at not greater that five foot spacing.

Life line shall be 3 /4" minimum diameter and its terminals shall be securely anchored and of corrosion resistant material and of type which will be recessed or have

no projections which will constitute a hazard. A life line shall not be required during a period restricted to competition and/or

lap swimming.

31.2 Every swimming pool shall be equipped for safety and rescue with one or more light but strong poles (bamboo or other), or shepherds' crook, having blunt end and which is not less than 16 feet of length for making reaching assists or rescues.

31.3 Every pool shall be equipped with one or more throwing buoys of not more than 18 inches in diameter with 1 /4" line attached at least equal in length to the maximum width of the pool plus ten feet.

31.4 Lifesaving equipment described in paragraphs 31.2 and 31.3 above shall be mounted in conspicuous places near the pool edge, ready for access, its function plainly marked, kept in good repair and ready condition, and bathers or others shall not be permitted to tamper with it, use it for any purpose other than its intended use, or remove it from its established location.

31.5 Every swimming pool shall be equipped with a standard 24-unit first aid kit. The first aid kit shall be kept filled and readily accessible for emergency use. A backboard is advisable for isolated areas and for large pools. Comment: the governing authority can require additional first aid materials depending on distance of pool to medical facilities and availability of emergency medical services.

31.6 One lifeguard chair should be provided for each 2,000 square feet of pool surface area or fraction thereof. If a pool is

more than 40 feet wide and requires more than one lifeguard stand, these stands should be located on opposite sides of the pool.

31.7 All glass is prohibited in the pool enclosure. Any broken glass or any other sharp surface in the pool enclosure, capable of cutting a patron, will be a violation of this regulation.

Section 9-7032. Public Spas.

32.1 Definitions.

1. Public Spas (including hot tubs and recreational whirlpools). Any pool other than a private residential pool primarily designed for individual or small group bathing with circulated water which may employ tempered water, air

induced bubbles or combination thereof with the intent of producing a relaxing or therapeutic effect operated by any person as defined herein, whether he be

owner, operator, lessee, licensee, or concessionaire, regardless of whether a fee is charged, and all facilities incident thereto.

2. Private Residential Spas. Any pool as defined in 32.1.,a., but for a single family residence under the control of the individual homeowner, the use of which is limited to members of his family or their

invited guests.

32.2 Shape, Slope, and Depth. Maximum water depth shall be four feet measured form the water line.

32.3 Steps, Ladders, and Handrails. The maximum depth of any seat or sitting bench shall be two feet measured from the water line. Seat or bench may be part of steps.

32.4 Recirculation and Filtration System.

1. Recirculation capacity shall provide for complete turnover of the pool content ever 30 minutes.

2. The pool recirculation and filtration system, air induction system, booster pump system when used, heater, and disinfectant system shall be separate equipment from that used by the swimming

pool. However, all equipment may be located in the same room.

3. The maximum temperature of the pool water shall be 105 degrees.

A thermostatic control for pool water shall be required and shall not be for patron use.

4. The air induction system shall prevent water back-up and the air source shall not induce contaminants.

32.5 Bathhouse Facilities.

1. Where the pool is adjacent to a swimming pool facility and patron control is through the swimming pool bathhouse, the spa pool patron load shall be included in

swimming pool load.

2. For separate pool facilities, a shower, lavatory, water closet and dressing room shall be provided for each 36 patrons of each sex. A drinking fountain shall be required.

32.6 Safety Precautions.

1. Where the pool is adjacent to a swimming pool facility and patron control is through the swimming pool bathhouse, the requirements of this section are not applicable.

2. For separate pool facilities, the requirements of this section are not applicable, except for emergency use, a telephone or emergency signal shall be directly connected to an area that is attended at all times the pool is open to

patrons. Emergency procedures and pool use regulations shall be posted.

Section 9-7033. Natural Public Bathing Beaches.

33.1 Definitions shall apply and shall be amended as follows:

1. Natural Public Bathing Beaches.

Any natural or altered body of water such as, but no limited to, an artificial or natural pond, spring, lake, river, or stream for swimming, diving, or recreational bathing, for collective use by a number of persons operated by any person as defined herein, whether the owner, operator, lessee, licensee, or concessionaire, regardless of whether a fee is

charged, and all facilities incident thereto.

2. Private Residential Natural Bathing Beach. Any natural bathing body of water as defined above

for a single family residence under the control of an individual homeowner, the use of which is

limited to swimming and bathing by family members or their invited guests.

33.2 Plans and specification as required by Gwinnett County Planning and Development Department shall apply to facilities incident to the Natural Public Beach.

33.3 The Georgia State Plumbing Code shall apply to water supply facilities incident to the Natural Public Beach.

33.4 For water depths up to four feet six inches, the beach bottom should consist of stabilized sand and/or gravel and the bottom slope should not exceed one foot in 15 feet.

33.5 The water depth surrounding any diving float or fixed platform not more than two meters above the water surface shall be not less than nine feet for a distance of not less than 12 feet from all sides of the float or platform.

33.6 Gwinnett County Electrical Code shall apply to Natural Public Beaches.

33.7 Bathhouses and bathhouse facilities regulations shall apply to Natural Public Beaches. The Director, Gwinnett County Board of Health may exclude shower facilities requirements.

33.8 The user load determination shall be made during the preliminary design phase.

The owner (operator), prime design professional and the Director, Gwinnett County Board of Health or his representative and

the Gwinnett County Department of Planning and Development should agree on beach capacities depending on the establishment or areas served.

33.9 The Natural Public Beach water quality shall meet or exceed those established by the Department of Natural Resources,

Rules and Regulations for Water Quality Control for Criteria for All Water and Recreation Water Use Classification. The location of the beach shall be on a body of water classified as recreational as determined by the Department of Natural Resources.

ARTICLE B. PUBLIC SPA POOLS AND

BATHHOUSES

Sections 9-7034—9-7068. Reserved.

ARTICLE C. ADMINISTRATION AND

ENFORCEMENT

Section 9-7069. Variance.

This chapter shall be administered by the Director, Gwinnett County Board of Health, who shall have the authority to grant a variance from the requirements of this chapter as follows:

1. Where it is demonstrated to the satisfaction of the Director that strict compliance with the standards would result in practical difficulty to or undue hardship upon the property owner due

to special conditions or causes;

2. Where the public or private interest in the granting of the variance is found by the director to clearly outweigh the interest of the application of uniform rules; and,

3. Where such alternative measures are provided which in the opinion of the director will provide adequate public health and safety protection. In granting a variance, the director may attach thereto any conditions which may be deemed advisable so that the purpose of this chapter will be served, public health, safety and welfare secured. Such variance shall not waive any requirement of other Federal,

State, or County Codes which may also be applicable to the design, construction or operation of any items covered by these Health Regulations.

Section 9-7070. Severability.

Should any court of this state or of the United States declare any section, part, paragraph or clause of this chapter unconstitutional or invalid for any cause or reason, then such decision shall affect only that section,

part, paragraph, or clause so declared to be unconstitutional and invalid, and shall not affect any other section, part paragraph or clause of this chapter.

Section 9-7071. Conflicts With Other Codes, Laws, or Regulations.

Nothing in this resolution is intended to, nor will it serve to supersede any other Federal, State, or County Code, regulation, or ordinance. Where a conflict may be deemed to exist, the stricter shall apply.

Section 9-7072. Enforcement.

This regulation, upon adoption by the Gwinnett County Board of Commissioners shall be enforced by the Gwinnett County Board of

Health, as a duly adopted ordinance of Gwinnett County. Any person violating any provision in this regulation shall be guilty of violating a duly adopted ordinance of Gwinnett County, and upon conviction by a court of competent jurisdiction shall be punished

either by a fine not to exceed $500.00, or by confinement in the county jail for a total term not to exceed 60 days, or both.

The court shall have the power and authority to place any person found guilty of a violation of this regulation on probation and

to suspend or modify any fine or sentence. As a condition of such suspension, the court may require payment of restitution or impose other punishment allowed by law.

CHAPTER IV. TOURIST

ACCOMMODATIONS*

290-5-18-.01. Definitions.

The following definitions shall apply in the interpretation and enforcement of these rules:

(a) "Tourist accommodation" means a tourist court as defined in O.C.G.A.

Chapter 31-28 as any facility consisting of two or more rooms or dwelling units providing lodging and other accommodations for tourists and travelers and includes tourist courts, tourist cottages, tourist homes, trailer parks,

trailer courts, motels, motor hotels, hotels, and any similar place by whatever name called and any food, beverage, laundry, recreational or other facilities or establishments operated in conjunction therewith. This definition

includes any facility consisting of two or more rooms or dwelling units either joined together or separate on a common piece of property, furnished for pay and further includes campgrounds.

recreational vehicle parks and bed and breakfast inns.

(b) "Bed and breakfast inn" means an establishment of 20 guestrooms or less, which serves food only to its registered guests, and serves only a breakfast or similar early morning meal and an appropriate light snack in which

the price of the food is included in the price of the overnight accommodation.

For purposes of these rules, "Bed and Breakfast Inn" refers to an establishment in which the predominant relationship between the occupants thereof and the owner or operator of the establishment is that of innkeeper and guest.

(c) "Tourist" or "traveler" is defined as anyone who has a home address somewhere else other than where he is spending the night.

(d) "Operator" means the person who has the duty and responsibility of overall management of the tourist accommodation or his representative.

(e) "Person" means any individual, partnership, corporation and association and may be extended and be applied

to bodies, politic and corporate.

(f) "Continental breakfast" is defined as and may include any non-potentially hazardous food which is served in single serving commercially packaged original containers. It may also include non-potentially hazardous beverages such as coffee and hot tea served in the container in which it was prepared. It may include potentially hazardous foods such as milk, cream, butter and cheese only if served in

single serving commercially packaged original containers. Likewise, juices and condiments including jams, jellies, sugar, salt and pepper may be served only in single serving commercially packaged original containers.

(g) "Potentially hazardous food" means any perishable food which has as an ingredient milk or milk products, eggs, meat, poultry, fish, shellfish or other foods or other ingredients in such forms as are capable of supporting rapid and progressive development of infectious or disease causing agents. The term does not include foods which have a pH level of 4.6 or below or a water activity value of 0.85 or less.

(h) "Residential kitchen" means a kitchen within a bed and breakfast inn used for the owners private use as well as preparation of a breakfast meal for guests.

(i) "Trailer" means any house trailer, trailer coach, mobile home, motor home or other similar unit so designed or constructed as to permit occupancy for dwelling or sleeping purposes.

(j) "Dependent trailer" means a trailer which is dependent upon a service building housing toilet facilities.

(k) "Independent trailer" means a trailer which has its own holding tank for waste and/or can be connected directly to a sewer connection.

(l) "Trailer space" means a plot of ground within a trailer park designated for the accommodation of one trailer.

(m) "Premises" means and includes all physical buildings, appurtenances, parking lots and all property owned and/or used by the tourist accommodation.

(n) "Employee" means any person who is paid, volunteers or otherwise is engaged in the operation of the tourist accommodation.

(o) "County board of health" means the county board of health established by the Georgia Health Code (O.C.G.A.

§ 31-3-1) or its representative.

(p) "Department" means the Department of Human Resources of the State of Georgia.

(q) "Health authority" means the county board of health if functioning in the administration and enforcement of O.C.G.A. Chapter 31-28 and the rules, regulations and standards adopted thereunder; and if not so functioning, the department.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Foreward" was filed and effective on July 19,1965. As 270-5-13-.01. Amended:

Rule repealed and a new Rule entitled "Definitions" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule remembered as 290-5-18-.01.

Filed June 10, 1980; effective July 30, 1980. Amended:

Rule repealed and a new Rule of the same title adopted.

Filed March 28, 1984. Effective April 27, 1984. Amended:

Rule repealed and a new Rule of the same title adopted.

Filed March 5, 1996; effective March 25, 1996.

290-5-18-.02. Provisions.

(1) Permit:

(a) Any person operating a tourist accommodation shall possess and display prominently in public view and as

designated by the health authority, a valid permit issued by the health authority on forms prepared by the department.

(b) To be eligible for a permit the tourist accommodation shall be in satisfactory compliance with these rules and regulations and the provisions at law

which apply to the location, construction and maintenance of tourist accommodations and the safety of persons therein.

(c) Application for a permit to operate such tourist accommodations shall be made in duplicate upon forms provided by the department. Such forms shall be completed in all details and

signed by the applicant or his authorized agent and submitted at least ten days before the scheduled opening.

The original shall be filed with the health authority.

(d) Upon receipt of an application for permit the health authority shall review the application and shall take such

action relative to approve or deny the permit as is provided in accordance with the provisions of O.C.G.A. Chapter 31-28 and these regulations.

(e) The permit if granted or a statement of reasons if denied shall be forwarded to the tourist accommodation operator by the health authority.

(f) A permit shall not be transferable with respect to person or location.

(g) The permit shall be the property of the health authority and shall be returned within seven days to the local health authority when the tourist accommodation ceases to operate or is moved to another location.

(h) Where local, state or federal rules and regulations apply which are deemed more stringent, they shall apply in lieu of the applicable section(s) herein.

(2) Plans: Plans and specifications for remodeling tourist accommodations and construction of new tourist accommodations must be submitted for review and approval. Plans

must be submitted 14 days prior to beginning construction. The plans shall indicate the proposed layout and arrangement of rooms in establishment and what each is to be used for. Mechanical and plumbing details must be shown as well as construction materials to be used on floors, walls and ceilings. Additional plans for kitchen will be required if food is to be prepared and served to guests. A

copy of the menu or list of foods to be served will be required also. If no construction changes are to be made to an existing building, requirement for plans will be at the discretion of the health authority.

(3) Private camps: Camps or facilities owned and operated solely for members only will be inspected only at the health authority's discretion or upon request by the owner or operator.

Authority O.C.G.A. §§ 31-28-2 and 31-28-5. Administrative History. Original Rule entitled "Authority (Quotation)" was filed and effective on July 19,1965 as 270-5-13-.02. Amended: Rule repealed and a new Rule entitled "Provisions" adopted. Filed October 18, 1967;

effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.02. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the same titled adopted. Filed March 28, 1984.

Effective April 27, 1984. Amended: Rule repealed and a new Rule of the same title adopted. Field March 5,

1996; effective March 25, 1996.

290-5-18-.03. Procedures.

(1) All tourist accommodations shall be subject to inspection at reasonable hours no less than twice annually and as often as is deemed necessary by the health authority to insure adequate compliance with the provisions of these rules.

(2) The operator may accompany the health authority representative on tours of inspection, shall be given the opportunity to sign the completed inspection report and retain a

copy for the tourist accommodation's file.

(3) The signature of the operator shall not mean his agreement with all of the findings recorded thereon, but shall mean his receipt of the report and the notification of alleged non-compliances with the rules.

(4) The report of inspection shall be recorded on a form provided by the department.

This report will show violations found, corrective actions necessary for compliance with this rule, date of inspection, signature of

person making inspection and the date when it is anticipated corrections to violations will be completed.

(5) The entire report shall be discussed at the time of inspection with the tourist accommodation operator and explained.

(6) The most recent inspection report shall be posted in public view near the main entrance of the tourist accommodation, in a location determined by the health authority.

(7) The health authority shall review all reports on reinspection and on the basis of corrective measures taken shall institute such action as is deemed proper in accordance with the provisions of O.C.G.A. Chapter 31-28 and these regulations.

Authority O.C.G.A. § 31-28-6 and 43-21-51 Administrative History. Original Rule entitled "Definitions" was filed and effective on July 19,1965 as 270-5-13-.03.

Amended: Rule repealed and a new Rule entitled "Procedures" adopted. Filed October 18, 1967; Amended:

rule renumbered as 290-5-18-.03. Filed June 10, 1980.

Amended: Rule repealed and a new Rule of the same title adopted. Filed March 28, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule of the

same title adopted. Field March 5, 1996. effective March 25, 1996.

290-5-18-.04. Employee Health and Safety.

(1) No person while affected with any disease in a communicable form, or while a carrier of such disease, or while afflicted with

boils, infected wounds or sores shall work in any area of a tourist accommodation in any capacity is which there is a likelihood of such a person contaminating bedding and other surfaces with pathogenic organisms or transmitting disease to other individuals and no person known or suspected of being affected

with any such disease or condition shall be employed in such an area or capacity. When there is reason to suspect that any employee has contracted any disease in communicable form or has become a carrier of such a disease, the employee shall be (a) removed from the tourist accommodation premises: or (b)

his service be restricted to some area of the establishment where there would be no danger of transmitting disease.

(2) Employees, other than clerical employees, shall thoroughly wash their hands and the exposed portions of their arms with soap

and warm water before starting work, during work as often as necessary to keep them clean and after smoking, eating, drinking or using the toilet. Employees shall keep their fingernails clean. Employees shall maintain a high degree of personal cleanliness and conform to other good hygienic practices.

Hand sinks shall be provided on each floor for employee use. These hand sinks shall be located in employee work areas, i.e. linen storage, chemical storage, or maintenance.

Hot and cold water under pressure and soap and paper towels in a dispenser shall be provided at each sink.

Authority O.C.G.A. § 31-28-5. Original Rule entitled "Permit" was filed and effective on July 19,1965 as 270-5-13-.04. Amended: Rule repealed and a new Rule entitled "Water Supply" adopted. Filed October 18,

1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.04. Filed June 10, 1980. Effective June 30, 1980. Amended: Rule repealed and a new Rule of the same title adopted. Filed March 28, 1984:

effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Employee Health and Safety" adopted. Filed March 5, 1996; effective March 8, 1996.

290-5-18-.05. Water Supply.

(1) The water supply shall comply with all Federal, State and local laws and/or ordinances related to safe drinking water.

(2) Cold running water under pressure shall be provided to all equipment that uses water. Hot and cold running water under pressure shall be provided to all lavatories, bathing facilities, laundry facilities, and all water-using equipment where eating and drinking utensils are washed. In all new tourist accommodations and where possible in existing tourist accommodations, hot water in all guest rooms shall not exceed 120°F.

(3) The water supply shall be adequately protected to preclude the possibility of back siphonage. Below grade stop and wastes cocks or hose bibs shall not be used.

(4) Hose used for filling trailer water tanks shall be stored under sanitary conditions, used for no other purposes and be so handled that back siphonage cannot occur and that contaminants will not be intreduced into the trailer's water tank. Hoses used for filling water tanks shall be of commercial foodgrade material.

(5) Where water glasses, ice buckets and other multi-use utensils are used, they shall be cleaned and sanitized, in a manner approved by the health authority, alter each occupancy. Where approved sanitizing methods are not provided, single service paper or plastic cups shall be made available in lieu of

glasses and shall be used only once. In lieu of sanitizing ice buckets, a sanitary, food grade, plastic bag, large enough to line the bucket and overlap the top edge may be provided for use by one occupancy only.

(6) Dishmachines provided in guest rooms shall be equipped with a high temperature sanitizing cycle producing a minimum water temperature of 155°F. A maximum registering thermometer or a heat thermal label shall be provided for determining the water

temperature of each machine during sanitization. The temperature must be checked weekly and recorded in a log This log must be

available for inspection.

(7) Single service items shall be commercially pre-wrapped to protect against contamination. Water glasses and other multi-use utensils shall be protected from contamination in a manner approved by the health authority. Equipment, utensils. dishes, etc.

in kitchenettes provided for guest use, shall be kept clean. Dishwashing detergent shall be provided for guest use.

(8) Drinking founts shall be constructed of impervious material and shall have an anglejet nozzle above the overflow rim of the bowl.

The nozzle shall be protected by a nonoxidizing guard and the bowl shall be constructed of an easily cleanable material.

(9) Where self-service ice is provided, it shall be from an approved water supply source.

In all new tourist accommodations and in existing tourist accommodations when machines are replaced, only automatic dispensing ice machines will be allowed. In existing tourist accommodations permitted prior to

the adoption of this rule, self-service icestorage bins presently being used may be continued, provided that the machines are

maintained in good repair and capable of being properly cleaned. Scoops, ice buckets and other ice handling equipment shall be of easily cleanable material and construction shall be stored in a clean place and shall be kept clean. Glass ware shall not be used to scope ice.

(10) Facilities providing food service shall provide a separate water heater for the food service.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Procedures" was filed and effective on July 19,1965 as 270-5-13-.05. Amended:

Rule repealed and a new Rule entitled "Toilet Facilities" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18- .05. Filed June 10, 1980. Effective June 30, 1980.

Amended: Rule repealed and a new Rule of the same title adopted. Filed March 28, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Water Supply" adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.06. Toilet Facilitlea.

(1) Toilet, lavatory and bathing facilities shall be provided at all tourist accommodations except as provided in paragraphs (9) and (12) of this section. Such facilities shall

be easily accessible, convenient and available to patrons at all times.

(2) Bedrooms in permanent structures shall be provided with private or connecting baths except, however, central toilet facilities may be used to serve bed and breakfast inns and existing multi-storied tourist accommodations provided toilet facilities are within the building, located on each floor and adequate

by determination of the health authority, to serve the tourists therein.

(3) Toilet rooms and fixtures shall be kept clean and in good repair. Walls and ceilings shall be constructed of easily cleanable materials and shall be kept clean and in good repair.

(4) Toilet, lavatory and bathing facilities shall be ventilated. Where ventilation ducts are used, ducts from toilet rooms shall not be connected into return ventilation ducts to any other room.

(5) Toilet rooms, lavatories and bathing facilities shall be provided with soap, artificial light and hot and cold water under pressure.

(6) Unused, individually wrapped soap or liquid soap dispensed from approved containers shall be provided in guest rooms. Soap furnished in public wash rooms or baths shall

be dispensed from approved containers in such a manner that contamination of the contents by individual contact is impossible.

(7) Individual towels shall be provided in guest rooms and shall have been laundered, since last used, by a method approved by the health authority used. if fabric bath mats are provided, they shall have been laundered or cleaned since last used. Towels, whenever provided in the public wash rooms or baths, shall be individual towels and if cloth, shall have been laundered since last used.

(8) Toilet tissue shall be provided in a dispenser at each toilet.

(9) Where dependent trailers are located, central toilet facilities shall be provided for each ten trailer spaces or fraction thereof, and for each ten dwelling units of nonpermanent structure, or fraction thereof, with not less than one commode, one lavatory and

one tub or shower head for each sex. In addition, at least one urinal shall be provided in each central toilet designated for men. It is not required for independent trailer sites to have access to central toilet facilities.

(10) Central toilets shall be plainly marked, separate for each sex, lighted at night and located within 200 feet of the dwelling units or trailer spaces served.

(11) Anti-slip tubs, slip strips, appliques or slip-proof mats shall be provided in each bathing facility and shall be kept clean and in good repair.

(12) Remote, primitive or wilderness campsites may not be required to provide toilet facilities in accordance with this rule, at the

discretion of the health authority. If facilities are not provided in accordance with this rule, a sign shall be posted at main entrance notifying campers of what facilities are/are not available.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Appeal to Superior Court" was filed and effective on July 19,1965 as 270-5-13-.06.

Amended: Rule repealed and a new Rule entitled "Sewers" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as

290-5-18-.06. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the

same title adopted. Filed March 28, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Toilet Facilities" adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.07. Sewers.

(1) Sewers shall be designed in accordance with recognized engineering practices for the estimated sewage flow and shall be laid with watertight joints to a grade that will insure a self-cleaning velocity. Sewers shall be constructed of durable materials properly vented and shall be installed at sufficient depth to

withstand anticipated loads or other equally suitable means for protection of the pipe shall be used.

(2) Each independent trailer space shall be provided with a sewer connection not less than three inches in diameter. Suitable fittings shall be provided at each sewer connection to permit a watertight junction to be made with the trailer outlet. Each sewer

connection shall be so constructed that it can be closed and when not in use shall be capped to prevent escape of odors.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Requirements" was filed and effective on July 19,1965 a 270-5-13-.07. Amended:

Rule repealed and a new Rule entitled "Sewage Disposal" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5- 18-.07. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule of the same title adopted. Filed March 24, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Sewers" adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.08. Sewage Disposal.

(1) Connection shall be made to a public sewer whenever possible and feasible as determined by the health authority or other appropriate governmental agency.

(2) Where public sewers are not available, as determined by the local governing agency, sewage disposal shall be provided to effectively dispose of all water carried wastes in a sanitary manner. No sewage, waste water, or

other liquid effluent shall be discharged in such manner as to enter surface or subsurface water except following a treatment process approved prior to construction in conformity with existing State and local laws. Such sewage disposal systems shall be constructed

and maintained in a manner to prevent the creation of unsanitary conditions. Existing private sewage disposal systems giving satisfactory service as determined by the health authority may be approved by said authority.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Housing Requirements" was filed and effective on July 19,1965 as 270-5-13-.08.

Amended: Rule repealed and a new Rule entitled "Plumbing" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as

290-5-18-.08. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the

same title adopted. Filed March 28, 1984, as specified by the Agency. Amended: Rule repealed and a new Rule entitled "Sewage Disposal" adopted. Filed March 5,

1996; effective March 25, 1996.

290-5-18-.09. Plumbing.

All plumbing in tourist accommodations shall comply with state and local laws, ordinances or regulations. In the absence of state and local laws, ordinances or regulations, the

provisions of the current "Southern Plumbing Code" as published by the American Society of Mechanical Engineers shall prevail.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Toilet Rooms" was filed and effective on July 19,1965 as 270-5-13-.09. Amended:

Rule repealed and a new Rule entitled "Refuse Disposal" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5- 18-.09. Filed June 10, 1980; effective June 30, 1980.

Amended: Rule repealed and a new Rule of the same title adopted. Filed March 28, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Plumbing" adopted. Filed March 5, 1996; effective

March 25, 1996.

290-5-18-.10. Garbage and Refuse Disposal.

(1) At least one health authority approved indoor container for waste shall be provided for each indoor dwelling unit to be rented.

Containers shall be constructed of durable metal or other materials which do not leak, do not absorb liquids and do not support combustion. Such containers shall be thoroughly cleaned on the inside and outside each time they are emptied unless liners are

used.

(2) All outside refuse or garbage storage containers shall be constructed of durable metal or other approved types of materials, which do not leak and do not absorb liquids and shall be provided with tight-fitting lids or covers and shall, unless kept in a special vermin proof room or enclosure, be kept covered when stored. Each container shall be located within 100 feet of dwelling units or

trailer spaces or in a location approved by the health authority and shall be cleaned at such frequency as to prevent a nuisance or odor.

(3) Adequate cleaning facilities shall be provided and each garbage and/or recycling storage room, enclosure or container shall be thoroughly cleaned after the emptying or removal of refuse or garbage. Areas surrounding these rooms, enclosures and containers shall be kept clean and orderly. Liquid waste

resulting from the cleaning of containers shall be disposed of as sewage.

(4) Refuse shall be collected in accordance with municipal practices where available.

Where such services are not available the tourist accommodation shall dispose of the refuse in compliance with all Federal, State, local laws and or ordinances.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Laundry Room" was filed and effective on July 19,1965 as 270-5-13-.10. Amended:

Rule repealed and a new Rule entitled "Insect and Rodent Control" adopted. Filed October 19,1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.10. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the

same title adopted. Filed March 28, 1984. Amended:

Rule repealed and a new Rule entitled "Garbage and Refuse Disposal" adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.11. Insect and Rodent Control.

(1) Effective measures, approved by the health authority, intended to eliminate the presence of rodents and flies, roaches and other insects on the premises shall be utilized. The premises shall be kept in such condition as to prevent the harborage or

feeding of insects or rodents.

(2) Openings to the outside shall be effectively protected against the entrance of rodents and shall be protected against the entrance of insects by tight-fitting doors, closed

windows, screening, controlled air currents or other means. Screen doors shall be selfclosing and screens for windows, doors, skylights, transoms and other openings to the outside shall be tight-fitting and free of breaks.

Screening materials shall not be less than sixteen mesh to the inch. Screen doors for sliding patio doors will not be required to be self closing except in food service, preparation and utensil washing areas of permitted food service establishment kitchens and bed

and breakfast inns.

Authority O.C.G.A. § 31-2805. Administrative History. Original Rule entitled "Water Supply" was filed and effective on July 19,1965 as 270-5-13-.11. Amended:

Rule repealed and a new Rule entitled "Housing" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.11. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Construction Layout and Furnishings" adopted. Filed March 28, 1984; effective April 27, 1984. Amended: Rule repealed and a new Rule entitled "Insect and Rodent Control" adopted.

Filed March 5, 1996; effective March 25, 1996.

290-5-18-.12. Construction, Layout and Furnishings.

(1) Floors, walls, ceilings, windows, doors and all other appurtenances shall be of sound construction, properly maintained in good repair and shall be kept clean. In all new constructed and extensively remodeled residential kitchens used in bed and breakfast inns, coved base molding may be required.

Walls and ceilings in residential kitchens shall be easily cleanable and light colored.

Recognition of a bed and breakfast inn's historical integrity should be considered.

(2) Ventilation shall be provided for all rooms. Where ventilation is provided by means of windows, they shall open directly to the outside air and the openable window area of each room shall be not less than 1 /20 of the floor area served. Where ventilation is provided by other means, it shall be at the rate of one complete change of air each 20 minutes

so as to provide comfortable living conditions, remove objectionable odors and fumes and prevent excessive condensation. Ventilation systems shall be subject to applicable State and local fire prevention requirements and building codes.

(3) All rooms shall be well lighted. When natural light falls to provide sufficient illumination, evenly distributed artificial light shall be provided to maintain a lighting intensity

of not less than ten foot candles at 30" above floor levels.

(4) Furniture, draperies, carpets and other accessories shall be maintained in good repair and shall be kept clean.

(5) Washable mattress pads or covers shall be used on all mattresses. Beds, mattresses, springs, slats, mattress pads, mattress and bed coverings, pillow and pillow covers shall be clean and free from vermin. Each bed shall be provided, as a minimum, with two sheets and one pillow and pillowcase. Sheets and pillowcases shall be changed daily during the occupancy and after each occupancy with freshly laundered linens. During occupancy, daily changing of linens may be waived if written notice is given to the occupant.

(6) Sleeping quarters must be separated by a wall from the food preparation, food storage and food service areas of a bed and breakfast inn.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Plumbing" was filed and effective on July 19,1965 as 270-5-13-.12 Amended:

Rule repealed and a new Rule entitled "Fire Protection" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.12. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Heating" adopted.

Filed March 28, 1984; effective April 27, 1984. Amended:

Rule repealed and a new Rule entitled "Construction, Layout and Furnishings" adopted. Filed March 5, 1996;

effective March 25, 1996.

290-5-18-13. Heating and Fire Safety.

(1) The construction and installation of the heating appliances shall be such that all of the flue gases shall be carried to the outside of building through the flue outlet.

(2) Unvented combustion type heaters shall not be installed and/or used on the premises.

(3) All automatic natural gas heating equipment shall be equipped with automatic safety pilot. All liquefied petroleum gas burning

appliances shall be equipped with 100% safety cut-off pilot.

(4) Gas water heaters shall not be installed in bathrooms and bedrooms or closets connected thereto.

(5) Each gas-fired heating unit shall be inspected at least annually by a qualified heating contractor before its use at the onset of cool weather. Points to be inspected are proper construction and installation, malfunctions and adjustments of controls and burners, faulty heat exchangers and vent obstructions. Any defects found on inspection must be corrected by a qualified heating contractor

prior to use of the equipment. Upon request, the operator shall provide evidence of inspection and/or correction of any deficiency.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Sewers" was filed and effective on July 19,1965 as 270-5-13-.13. Amended:

Rule repealed and a new Rule entitled "Heating" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.13. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule entitled "Food Service" adopted. Filed March 28, 1984; effective April 27, 1984.

Amended: Rule repealed and a new Rule entitled "Heating and Fire Safety" adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.14. Swimming Pools.

(1) Regulations of the department and/or county (whichever is applicable) shall be applicable in the design, construction, operation and maintenance of swimming pools operated in conjunction with a tourist accommodation.

(2) If a swimming pool at a bed and breakfast inn cannot comply with applicable regulations, it must be enclosed with a fence at least four feet in height with a locked gate

and used only by family members. In such case, guests shall not be allowed to use swimming pool.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Sewage Disposal" was filed and effective on July 19,1965 as 270-5-13-.14. Amended:

Rule repealed and a new Rule entitled "Food Services".

Filed October 18, 1967; effective November 6, 1967.

Amended: Rule renumbered as 290-5-18-.14. Filed June 10, 1980; effective June 30, 1080. Amended: Rule repealed and a new Rule entitled "Swimming Pools" adopted. Filed March 28, 1984; effective April 27, 1984.

Amended: Rule repealed and a new Rule of the same title adopted. Filed March 5, 1996; effective March 25, 1996.

290-5-18-.15. Laundry Rooms.

Where laundry facilities are provided, they shall be separate from other facilities, of sound construction and shall be kept clean and in good repair. Laundry rooms for guest use shall be vented to the exterior and shall be well lighted, ventilated and separate from tourist accommodation laundry facility. Laundry equipment shall be provided with hot and cold water under pressure. Dryers shall be

vented to the outside.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled "Heating" was filed and effective on July 19,1965 as 270-5-13-.15. Amended:

Rule repealed and a new Rule entitled "Laundry Rooms".

Filed October 18, 1967; effective November 6, 1967.

Amended: Rule renumbered as 290-5-18-.15. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the same title adopted. Filed March 28, 1984; effective April 27, 1984. Amended:

Rule repealed and a new Rule of the same title adopted.

Filed March 5, 1996; effective March 25, 1996.

290-5-18-.16. Grounds.

(1) The grounds of a tourist accommodation shall be graded to drain. Serviceable walks and driveways shall be provided.

(2) Grounds shall be kept clean and free of litter. Space beneath building and trailers shall be kept clean.

(3) All walkways, porches and hallways shall be maintained in good repair. Only articles necessary to the operation and maintenance of the establishment shall be stored on the premises.

(4) There shall be not less than 15 feet clear space between trailers and building, nor less than ten feet between trailers and internal driveways within the trailer park.

(5) Each trailer space shall be distinctly marked. Trailer spaces shall about on a welldefined all-weather driveway of not less than 20 feet of unobstructed width and such driveway shall have clear access to a public thoroughfare.

(6) Grounded and weather-proof electrical outlets supplying at least 115 volts shall be provided at each trailer space. Power lines shall be located under ground or suspended at least 18 feet above ground. All electrical work and materials shall comply with State and local laws, ordinances or regulations. In the absence of such State and local laws, ordinances or regulations, the provisions of appropriate sections of the "Southern Standard Building Code" as published by the Southern Standards Building Codes Conference shall prevail.

Authority O.C.G.A. § 31-28-5. Administrative History. Original Rule entitled Refuse Disposal" was filed and effective on July 19,1965 as 270-5-13-.16. Amended:

Rule repealed and a new Rule entitled "Grounds" adopted. Filed October 18, 1967; effective November 6, 1967. Amended: Rule renumbered as 290-5-18-.16. Filed June 10, 1980; effective June 30, 1980. Amended: Rule repealed and a new Rule of the same title adopted.

Filed March 28, 1984; effective April 27, 1984. Amended:

Rule repealed and a new Rule of the same title adopted.

Filed March 5, 1996; effective March 25, 1996.

290-5-18-17. Food Service.

(1) Food service facilities with exception only to bed and breakfast inns shall comply with provisions of O.C.G.A. Chapter 26-2.

Art. 13 and the rules, regulations and standards adopted thereunder.

(2) If a tourist accommodation does not have a food service permit with exception to a bed and breakfast inn, it will be allowed to serve only a continental breakfast. If a continental breakfast is served, the following requirements shall be followed.

(a) A minimum two-compartment sink, large enough to fully immerse the largest utensil used and a refrigerator which can maintain food temperatures at or below 41°F (5°C) shall be required. The need for a refrigerator

may be waived if no potentially hazardous foods are served.

(b) Condiments containing potentially hazardous ingredients and milk must be stored in refrigerator.

(c) A thermometer, accurate to ±3°F (±1.5°C) shall be provided in refrigerator and located to be easily readable.

(d) Only single service disposable plates, cups and utensils will be used.

(e) Ice used for keeping displayed foods cold must be constantly drained and cannot be used in beverages. If ice is needed for beverages, it must be dispensed from self service machines or presented in cups pre-filled by the

management. Pre-filling shall be done only with the use of an approved ice scoop.

(3) A bed and breakfast inn may serve a full meal prepared in a residential kitchen located within the inn, if the following requirements are met.

(a) Limited Service: Food may only be prepared for guests staying in rooms located in the bed and breakfast inn.

No catering off the premises will be allowed.

(b) Food Supplies:

1. Food shall be in sound condition and safe for human consumption.

Food shall be obtained from sources that comply with the applicable laws relating to food safety. The use of food in hermetically sealed containers that was not prepared in a food processing

establishment is prohibited. However, jams, jellies and preserves made at the bed and breakfast

inn from naturally high-acid fruits may be served to guests.

2. Fluid milk and fluid milk products used shall be pasteurized and shall comply with applicable

law. Dry milk and milk products used shall be made from pasteurized milk and milk products and shall be used only in cooking.

Raw milk shall not be provided or used.

3. Only clean shall eggs meeting applicable grade standards or pasteurized liquid, frozen or dry eggs or pasteurized dry egg products

shall be used.

4. Only ice which has been manufactured with potable water and handled in a sanitary manner

shall be used.

(c) Food Protection:

1. All food shall be prepared, stored, displayed, dispensed, placed, transported, sold and served so as to be protected from dirt, vermin, unnecessary handling, droplet contamination, overhead leakage or other contunination.

2. The temperature of potentially hazardous foods shall be 41°F (5°C) or below or 140°F (60°C) or above at all times, except during necessary times of preparation.

(a) Establishments permitted prior to the effective date of these "Rules" shall comply immediately with this Rule or may be allowed a maximum of two years to comply if existing equipment needs remodeling or new equipment must be acquired in order to maintain food at or below 41°F. Existing equipment must be updated with change of ownership. All existing equipment must be maintained properly including routine cleaning of coils and all other parts of the

cooling system. Proper food handling is mandatory to ensure that the minimal temperature requirement is obtained by precooling foods and minimizing opening of

cooling units. Existing equipment which cannot maintain foods at 41°F must maintain foods at or below 45°F.

Upon equipment failure, replacement equipment must be capable of maintaining food at or below 41°F.

(b) A thermometer accurate to ±3°F shall be provided for each refrigeration unit, shall be located to indicate the air temperature in the warmest part of the unit and shall be affixed to be readily visible.

(c) Containers of potentially hazardous food displayed for service may be placed in an ice bed or held by a similar

means which maintains the food at or below 41°F. An accurate easily readable metal probe thermometer suitable for measuring the temperature food shall be readily available on the premises.

3. Hermetically sealed packages shall be handled so as to maintain product and container integrity.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:lilburn/zoning/whole@2026-11-11-9dc83d57b4

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.