Ir al contenido
Georgia Commons
Menú

Lovejoy · Ordenanza de zonificación

Appendix A - ZONING / Article XI - SITE PLAN REQUIREMENTS

Sec. 1101. Conceptual site plan.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

Article XV of this appendix requires a conceptual site plan be submitted with any rezoning application for an RS-65, RM, RMTH, RMP, OI, NB, CB, GB, LI, HI and PUD zoning district. Said site plan shall meet the standards and content specifications outlined in this section.

1101.1. General standards and specifications. All required conceptual site plans shall meet the following standards and specifications:

(A) Said conceptual site plans shall include:

(1) A location map showing all principal arterial highways within two miles of the proposed district (no scale is required).

(2) Topography at ten-foot contour intervals (these intervals may be interpolated from the USGS maps or any other recognized source).

(3) Location and elevation of the 100-year floodplain on the property subject of the proposed zoning.

(4) Dimensions of the boundary of the proposed district.

(5) Date, north arrow and datum.

(6) Scale of the site plan.

(7) Name, address and telephone number of the owner of the property subject of the proposed zoning.

(8) Name, address and telephone number of the owner's representative who is capable of answering questions regarding the site plan.

(9) Location and description of proposed recreation and buffer areas.

(10) General layout of proposed major streets or driveways.

(11) Acreage of property and proposed number of residential lots, dwelling units or mobile home spaces (as appropriate).

(12) Location and acreage of all major utility easements greater than 20 feet in width.

(13) Approximate locations of proposed common driveways and parking areas exceeding 7,000 square feet, unless the zoning administrator deems a larger threshold to be appropriate.

(B) At least two copies of the conceptual site plan shall be submitted with the rezoning application.

(C) Scale of site plans shall be at one inch equals 100 feet unless otherwise approved by the zoning administrator prior to submission or stated elsewhere in this appendix.

1101.2. RS-65 and RMP districts. Standards and content specifications for conceptual site plans for proposed RS-65 and RMP districts are as specified under subsection 1101.1 of this section.

1101.3. RM and RMTH districts. Standards and content specifications for conceptual site plans for proposed RM and RMTH districts are as follows:

(A) As specified in subsection 1101.1 of this section;

(B) General layout of proposed circulatory systems; and

(C) Approximate locations of any proposed structures planned to be over three stories in height.

1101.4. OI, NB, CB, GB, LI and HI districts. Standards and content specifications for conceptual site plans for proposed OI, NB, CB, GB, LI and HI districts are as follows:

(A) As specified in subsection 1101.1 of this section;

(B) Approximate locations of proposed loading and unloading areas when abutting residential property or adjoining a principal arterial roadway; and

(C) Approximate locations of any proposed structures planned to be over 30 feet in height when abutting residential property.

1101.5. PUD districts. Standards and content specifications for conceptual site plans for proposed PUD districts are as follows:

(A) As specified in subsection 1101.1 of this section;

(B) Approximate locations and description of major or significant water bodies on the property of the proposed district;

(C) Approximate boundaries, and dimensions of said boundaries, of each specific use area proposed for the district. Separate use areas shall be shown as follows: Single-family detached housing areas with lots of at least 11,250 square feet, other single-family detached housing, fee simple attached townhouse, other multiple-family housing, commercial, office/institutional and industrial area;

(D) For each residential use area specified in subsection 1101.5(C) of this section, the number of dwelling units to be allowed by type of structure (single-family detached, single-family attached and multiple-family). Multiple family apartment areas should have a description of the proposed bedroom mix;

(E) Requirements specified in subsections 1101.3(B) and (C) of this section;

(F) For each office/institutional, commercial and industrial area the approximate location, maximum height and maximum square footage of each major structure (also the proposed uses to be allowed in each area);

(G) General layout of all proposed major collector streets; and

(H) Acreage of each of the proposed use areas specified in subsection 1101.5(C) of this section.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:lovejoy/zoning/1101@2026-11-11-6ce2c12e40