All Manufactured Homes shall:

1) Comply with all requirements of O.C.G.A §45‐5‐490, §45‐5‐491, §45‐5‐492, §45‐5‐493, and §45‐5‐494, and all decals required there under shall be located in a window facing the road.

2) Meet the requirements of the Manufactured Housing Construction and Safety Standards Act, 42 U.S.C. 5401‐ 5445 (the HUD Code), the Georgia Fire Safety Commissioner and the manufacturer’s specifications prescribed for the set-up of such dwelling units. These include but are not limited to:

a) footing;

b) piers;

c) tie downs, and

d) anchors.

3) Meet the requirements of the National Electrical Code (NEC) and the electric utility company providing electrical service.

4) Be connected to water and sewerage in compliance with all applicable ordinances of Madison.

5) Meet the adopted building, gas, plumbing, electric, and other codes and ordinances of Madison, Georgia.

6) Be located on a permanent foundation.

7) Multi-section manufactured homes outside of a Manufactured Home Park shall have a shall have a skirt wall consisting of one of the following: brick, block, or poured concrete. Block and poured concrete must have a stucco finish. If the multi-section is located within a Manufactured Home Park then the home must have a skirt wall consisting of one of the following: vinyl, block, or brick. Block must have a stucco finish. Single-section manufactured homes must have a skirt wall consisting of one of the following: vinyl, block, or brick. Block must have a stucco finish.

8) Have minimum poured footings of no less than 24” long by 24” wide by 6” deep.

9) Have original vinyl, wood or wood‐type siding. Metallic siding is not permitted.

10) Roof structures on a Manufactured home must have a gabled roof with a minimum slope of 2/12. Domed or flat roofs are prohibited. Roof materials may consist of shingles, corrugated metal or standing seam. Sheet metal and rolled roofing are not permitted.

11) Be provided with permanent landing and stairs, constructed of pressure treated lumber, masonry or other rot and decay resistant materials, sufficient to provide safe ingress and egress from all exits of the unit. Individual landings shall be a minimum four (4) feet by four (4) feet. Landings and stairs require guard rails and hand rails that meet the International Building Code.

12) Meet all other applicable state and county statutes, regulations and ordinances.

13) All manufactured homes produced, assembled, constructed, or built in Georgia must conform to the Act and the Rules and Regulations promulgated thereunder by the Secretary of U.S. Department of Housing and Urban Development as the construction standard for manufactured homes, found in the Title 24 C.F.R. Part 3280, adopted May 11, 1976, as amended.

14) Each section of each manufactured home shall have a metal label issued by the In-Plant Primary Inspection Agency (IPIA), indicating that the manufacturer has certified to the best of the manufacturer’s knowledge and belief that the home meets the applicable construction standards of the Act. The label shall be affixed in a permanent manner, generally at the rear of each section of the home.