A. Purpose and intent. The purpose and intent of this section is to provide a regulatory strategy for outdoor lighting that will permit reasonable uses of outdoor lighting for nighttime safety, utility, security, productivity, enjoyment and commerce; curtail and reverse the degradation of the nighttime visual environment and the night sky;
preserve the dark night sky for astronomy;
minimize glare, obtrusive light and artificial sky glow by limiting outdoor lighting that is misdirected, excessive or unnecessary; conserve energy and resources to the greatest extent possible; and help to protect the natural environment from the damaging effects of night lighting from human-made sources.
B. All outdoor illuminating devices must be installed in conformance with the provisions of this zoning code, the building code and the electrical code as applicable and under appropriate permit and inspection.
C. For all land uses, developments and buildings that require a permit, all outdoor lighting fixtures shall meet the requirements of this code.
All building additions of fifty (50) percent or more in terms of additional dwelling units, gross floor area, or parking spaces, either with a single addition or with cumulative additions subsequent to the effective date of this section, will invoke the requirements of this section for the entire property, including previously installed and any new outdoor lighting.
Cumulative modification or replacement of outdoor lighting constituting sixty (60) percent or more of the permitted lumens for the parcel, no matter the actual amount of lighting already on a nonconforming site, will constitute a major addition for purposes of this section.
D. Minor additions. Additions of less than fifty (50) percent of additional dwelling units, gross floor area, or parking spaces that require a permit, and that include changes to existing lighting require the submission of a complete inventory and site plan detailing all existing and any proposed new outdoor lighting. Any new lighting on the site must meet the requirements of this section with regard to shielding and lamp type.
E. Exempt lighting. The following luminaires and lighting systems are exempt from these requirements:
1. Interior lighting;
2. Lighting for pools used at night;
3. Underwater lighting used for the illumination of swimming pools and fountains;
4. Temporary holiday lighting which have to be removed after seven (7) days of the holiday passing;
5. Lighting required and regulated by the Federal Aviation Administration, or other federal, state or local agency;
6. Emergency lighting used by police, fire, or medical personnel, or at their direction;
7. All outdoor light fixtures producing light directly from the combustion of fossil
fuels, such as kerosene and gasoline; and
8. Security lighting controlled and activated by a motion sensor device for a duration of ten (10) minutes or less.
F. Prohibited lighting. The following lighting systems are prohibited:
1. Aerial lasers.
2. Searchlight style lights, temporary searchlights may be turned on for eight
(8) hours within a twenty-four-hour period and for no more than three (3) consecutive days, once each calendar year.
3. Other very intense lighting, defined as having a light source exceeding two
hundred thousand (200,000) lumens or intensity in any direction of two million (2,000,000) candelas or more; and
4. Sodium and Mercury vapor lamps.
5. Light strips around windows.
G. Outdoor lighting standards. All nonexempt outdoor lighting fixtures shall meet the following criteria:
1. Flood or spot lamps must be positioned no higher than forty-five (45) degrees
above straight down (half-way between the vertical and the horizontal) when the source is visible from any off-site
residential property or public roadway.
2. All light fixtures that are required to be shielded shall be installed and maintained in such a manner that the shielding is
effective as described herein for fully shielded fixtures.
H. Specific uses. All lighting not directly associated with the special use areas designated below must conform to the lighting standards described in this section.
1. Lighting of outdoor recreational facilities (public or private), such as, but not limited to, outdoor athletic fields, courts, tracks, special event or show areas, shall meet
the following requirements:
a. Luminaires. Facilities designed for municipal leagues, elementary to high school levels of play and training fields for recreational or social levels of play, college play, semiprofessional, professional or national levels of play shall utilize luminaires
with minimal uplight consistent with the illumination constraints of the design. Where fully shielded fixtures are not used, acceptable luminaires shall include those which:
1) Are provided with internal or external glare control louvers or lenses, and are installed so as to minimize uplight and offsite light trespass and glare;
and
2) Are installed and maintained so as to avoid aiming more than two and one-half (2.5) times the mounting height.
b. Illuminance. All lighting installations shall be designed to achieve the illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6).
c. Off-site spill. The installation must also limit off-site spill (off the parcel containing the sports facility) to the
maximum extent possible consistent with the illumination constraints of the design. For all recreational or social levels of play and training fields, as well as performance areas, illumination levels must not exceed one and one-half (1.5) footcandles at any location along any nonresidential property line, and onehalf (0.5) footcandles at any location along any residential property line.
d. Curfew. Field lighting for these outdoor athletic facilities shall be turned off within thirty (30) minutes after the last event of the night.
e. Setback. All light poles shall be set back the greater of fifty (50) feet or
one (1) foot for every foot in height from any residential property line or right-of-way.
2. Service station canopies and parking structures.
a. All luminaires mounted on or recessed into the lower surface of service station canopies and parking structures must be fully shielded and use flat lenses.
b. The total light output of luminaires mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels over the pumps, must not exceed fifty
(50) foot-candles.
c. The total light output of illuminated areas of a service station other than
as detailed above shall not exceed fifteen (15) foot-candles.
d. Illuminance levels for the interior of parking structures, where interior
lighting is visible from outside the structure, must conform to the IESNA recommendation (RP-20).
e. Lights must not be mounted on the top or sides of a canopy and the sides of a canopy must not be illuminated.
3. Security lighting.
a. Security lighting is lighting that provides a level of illumination to clearly identify persons or objects and creates a psychological deterrent to unwanted or unsafe activity in the area being protected.
b. Security lighting must be directed toward the targeted area, and not adjacent properties.
c. Sensor-activated lighting must be located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and the light must not be triggered by activity off the property.
4. Pedestrian path lighting. Lighting posts must not exceed sixteen (16) feet from
the finished grade.
5. Architectural accent lighting.
a. Fixtures used to accent architectural features, materials, colors, style of
buildings, landscaping, or art must be located, aimed and shielded so that light is directed only on those features. Such fixtures must be aimed or shielded to minimize light spill into the dark night sky in conformance with the luminaire standards.
b. Lighting fixtures must not generate glare, or direct light beyond the facade onto a neighboring property, streets or into the night sky.
6. Commercial parking areas.
a. All lighting fixtures servicing parking lots, except floodlights, must be cut off fixtures, directed downward
and not toward buildings or other areas.
b. The minimum illumination level for a parking lot is 0.4 foot-candles at grade level and the ratio of the average illumination to the minimum illumination must not exceed 4:1.
c. Floodlights must be aimed or shielded to minimize uplight.
d. Light poles used in parking lots must not exceed thirty-five (35) feet in height.
I. Administrative variance.
1. The director shall have the authority to grant a modification to the outdoor lighting standards. Such administrative variance requires review and approval of the applicant's written documentation and
justification that one or more of the following conditions exist:
a. How the proposed design and appearance of the luminaire are superior;
b. How light trespass and glare will be limited;
c. How the proposed solution will provide a benefit without negative impact on the health, safety, or welfare of the community.
2. The application may include the recommended practices of the Illuminating Engineering Society of North America, a
professional engineer, or other authority on outdoor lighting.
J. Plans and evidence of compliance.
1. Application. The applicant for any permit required by any provision of the laws of the City of McDonough in connection
with proposed work involving outdoor lighting fixtures must submit, as part of the application for permit, evidence that the proposed work will comply with this
section. Even should no other permit be required, the installation or modification, except for routine servicing and same-type lamp replacement of any
exterior lighting, will require submission of the information described below. The
submission must contain but is not necessarily limited to the following, all or part of which may be part or in addition to the information required elsewhere in the
laws of the city upon application for the required permit:
a. Plans indicating the location on the premises of each illuminating device, both proposed and any already existing on the site.
b. Description of all illuminating devices, fixtures, lamps, supports, reflectors, both proposed and existing. The description may include but not limited to catalog cuts and
illustrations by manufacturers.
c. Photometric data, such as that furnished by manufacturers or similar, showing the angle of cut off of light emissions.
2. Additional submissions. The above required plans, descriptions and data must be sufficiently complete to enable the department to readily determine whether compliance with the requirements of this section will be secured. If such plans, descriptions and data cannot enable this ready determination, the
applicant must submit additional evidence of compliance to enable such determination, such as certified reports of tests, provided that the tests have been
performed and certified by a recognized testing laboratory.
3. Subdivision plats. All new subdivided properties must submit information as
described above for installed streetlights and other common or public area outdoor
lighting.
4. Certification. For all projects, certification that the lighting as installed conforms to the approved plans shall be provided
by an illumination engineer/professional before the certificate of occupancy is
issued. until this certification is submitZONING 17.120.060 ted, approval for use by the issuance of the certificate of occupancy will not be issued.
K. Contracting with utilities. The mayor and city council may contract with public utilities for the purpose of carrying out the terms of this article.
L. Grandfathering. No outdoor lighting installed before the adoption of this section on January 1, 2025, is exempt from the regulations of this section unless it is grandfathered by permission of the director.