In addition to the development standards contained in articles I and II of this chapter, the following standards are required within P-R districts:
(1) Minimum floor area per dwelling unit.
a. Planned apartment home communities.
1. Unattached single-family home: 1,400 square feet per unit.
2. Duplex family dwellings: 1,100 square feet per unit.
3. Multiplex family dwellings: 900 square feet per unit.
b. Planned manufactured home communities. All manufactured homes: 900 square feet.
(2) Minimum development area.
a. Planned apartment home communities: two acres.
b. Planned manufactured home communities: five acres.
(3) Minimum setback. The front of all buildings must be at least 35 feet from the front property line.
(4) Minimum side yard. Minimum side yard shall be 20 feet.
(5) Minimum rear yard. Minimum rear yard shall be 30 feet.
(6) Maximum building height. Maximum building height shall be 35 feet. This height limit does not apply to projections not intended for human habitation, except for satellite, television, and radio antennas, to which this limit does apply. For buildings and structures with such projections, the minimum required yards must be increased one foot for every two feet (or part of two feet) of height greater than 35 feet.
(7) Maximum lot coverage by building. Maximum lot coverage by building shall be 30 percent.
(8) Sight distance. In order to assure maintenance of adequate sight distances at intersections, no fence, wall, shrubbery, or other obstructions to vision between the heights of three feet and 15 feet above the ground is permitted within 20 feet of the intersection of the rights-of-way of streets or of streets and railroads.
(9) Applicability to land, buildings, and open space. No building, structure, land, or open space may be used or occupied, and no building or structure or part of a building or structure may be erected, constructed, reconstructed, moved, or structurally altered, unless in conformity with all of the regulations specified for the district in which it is located.
(10) Every use must be on a lot. No building or structure may be erected or use established unless upon a lot as defined by this chapter.
(11) Minimum slab elevation. The base of the slab of each principal building shall be at least six inches above finished grade, with a minimum vertical rise of six inches for every 12 feet of horizontal run.
(12) Open space not to be encroached upon. No open space may be encroached upon or reduced in any manner except in conformity with the yard, setback, or off-street parking spaces, and other such required development standards contained in this chapter. Shrubbery, driveways, retaining walls, fences, curbs, and buffers are not considered to be encroachments of yards. Open space areas as required by this chapter must be permanently maintained as open space in accordance with the requirements of this chapter.
(13) Reduction of yards or lot area. Except as otherwise provided in this chapter, a lot existing at the time of passage of the ordinance from which this chapter is derived may not be reduced, divided, or changed so as to produce a tract of land which does not comply with the minimum dimension or area requirements of this chapter for the district in which it is located unless that reduction or division is necessary to provide land which is needed and accepted for public use.
(14) Lots with multiple frontages. In case of a corner lot or double frontage lot, front yard setback requirements apply to all lot lines abutting a street.
(15) Landlocked lots. Landlocked lots are not eligible for placement within a P-R zoning district.
(16) Street frontage. No principal building may be erected on any lot which has less than 90 feet of immediate frontage on at least one public street.
(17) Yards and other spaces. No part of a yard, other open space, off-street parking, or loading space required for another building may be included as a part of the yard, off-street parking, or loading space required for another building, except as specifically provided for in this chapter.
(18) Substandard lots. Substandard lots are not eligible for placement within a P-R zoning district.
(19) Encroachment on public rights-of-way. No building, structure, service area, required off-street parking, or loading/unloading facility is permitted to encroach on public rights-of-way.
(20) Physical design standards. Minimum design standards for driveways, loading area, and other such physical site improvements are contained in chapter 114. Consult chapter 114 for specific requirements.
(21) Off-street parking and service requirements. Reserved.
(22) Other applicable development regulations. Information concerning any other applicable development regulations may be obtained from the administrative officer.
(23) Signs. Minimum design and location standards for signs are contained in chapter
110. Consult chapter 110 for specific requirements.
(24) Development standards shown in approved development plan. Other development standards shown in an approved development plan apply only to the development shown on the specific development plan. Such development standards must be maintained. (See section 118-222 for related details.)
(25) Design standards for all P-R developments.
a. Generally. Condition of soil, groundwater level, drainage, and ground slope must not create hazards to the property, or to the health or safety of residents.
The site must not be exposed to objectionable smoke, noise, odors, or other adverse conditions; and no part subject to flooding or erosion can be used for any purpose that would expose people or property to danger.
b. Soil and ground cover. Exposed ground surfaces throughout the development must be protected with a vegetative growth that prevents soil erosion, standing puddles, and dust. If this is not possible, such areas may be covered with a solid material such as stone, or may be paved.
c. Site drainage. The ground surfaces throughout the development must be equipped to drain all surface water in a safe, efficient manner, either through grading or installation of drains.
d. Street width:
1. Internal streets: All internal streets must be paved. Minimum required width is as follows:
(i) No on-street parking: 22 feet.
(ii) Parking one side: 28 feet.
(iii) Parking both sides: 36 feet.
2. Dead end streets: All dead and streets must have a turn-around at the closed end, with an outside paved diameter of at least 82 feet.
e. Street lighting. Outdoor lighting is required which will provide the following average maintained levels of illumination for the safe movement of pedestrians and vehicles at night:
1. All parts of the street system of the development: ten footcandles.
2. Potentially hazardous locations, such as major street intersections, steps, and stepped ramps: individually lighted, with a minimum of 20 footcandles.
f. Street construction and design.
1. Pavement. All streets must be paved with a material and thickness which meets the standards specified in chapter 114.
2. Grades: Maximum permitted grade for streets is ten percent. Short runs with a maximum grade of 15 percent may be permitted upon specific approval of the administrative officer, if traffic safety is assured by adequate leveling areas, and avoidance of lateral curves.
3. Offset intersecting streets (street jogs) and reverse curves. Offset intersecting streets must be offset at the centerlines at least 150 feet. Reverse curves must be connected by a straight section that is at least 150 feet long.
g. Paved parking areas.
1. Paved off-street parking areas must be provided for the use of residents.
At least two spaces for each dwelling unit must be furnished. In a planned manufactured home community, resident parking must be furnished at the manufactured home space which it serves.
2. Paved parking areas for guests may be either on-street, in a separate off-street lot, or a combination of both. At least 0.2 paved guest parking spaces per dwelling unit must be furnished.
h. Walks.
1. Common walk system. Common walks, where provided, should be at least 31
/2 feet wide.
2. Individual walks. All dwellings must be connected either to paved streets, paved drives, or parking spaces adjacent to paved streets with a minimum width of two feet.
i. Service buildings and other such facilities. Service buildings, recreation buildings and other such facilities of the development must meet the requirements of applicable codes and development regulations adopted by the city.
j. Minimum common open space. Ten percent of total area undeveloped or common green space for public use.
(26) Planned apartment communities. The following required development standards apply only to planned apartment communities:
a. Maximum density: ten units per acre, if the building is a two story. Six per acre if the building is a single story.
b. Maximum lot coverage by building: 30 percent.
c. Minimum separation of units: 25 feet.
(27) Planned manufactured home communities. The following required development standards apply only to planned manufactured home communities:
a. ANSI A225.1: All requirements of ANSI A225.1 must be met by the planned manufactured home community. All manufactured homes must be installed in accordance with ANSI A225.1.
b. Maximum density: five units per net acre, where central sewage and water is provided.
c. Minimum development size: Five acres.
d. Minimum separation of dwelling units: 25 feet.
e. Minimum manufactured home space lot: 6,000 square feet.
f. Maximum manufactured home space coverage: 50 percent.
g. Minimum manufactured home space front yard: 20 feet.
h. Minimum floor area per dwelling unit: 1,400 square feet.
(28) Public water and sewage service required. All dwellings within P-R districts must be served by public water and sewage. Where such lines do not already exist, the developer is responsible for installation of them. (See chapter 114 for additional details on utility installation.)
(Ord. of 10-1-1996, § 1306; Res. of 11-15-2005(4), § 1; Res. of 5-17-2005, §§ 2—5; Ord. No.
2007-14, §§ 1—6, 12-13-07; Ord. No. 17-02, § 1, 5-15-2017) Secs. 118-224—118-254. Reserved.