1. Each trailer space within a park shall be provided with an all-weather surface of sufficient area to provide parking for both trailer and towing vehicles. All other exposed ground surfaces shall be covered or protected with a vegetative growth that is capable of preventing soil erosion and of eliminating dust.
2. Water supply connections shall be made to a public water system wherever possible and feasible, as determined by the Mitchell County Health Department. Where a public system is not available, a private system approved by the Mitchell County Health Department may be used.
a. The water supply shall be capable of supplying 50 gallons per space per day for all spaces lacking individual water connections, and 100 gallons per day for all spaces provided with individual water connections.
b. Each travel trailer park shall be provided with at least one water supply station per 100 trailer sites, or fraction thereof. Such water supply outlet shall consist of at least a hydrant, and the necessary appurtenances, and shall be protected against back flow and backsiphonage.
3. Connection shall be made to a public sewerage system whenever possible and feasible, as determined by the Mitchell County Health Department. Where a public system is not available, a private system approved by the Mitchell County Health Department and where applicable, the Georgia Water Quality Control Board may be used.
a. Each travel trailer parking area shall be provided with a sanitary station in the ratio of one 100 trailer spaces or fraction thereof, and shall be separated from any trailer space by a distance of at least 50 feet.
b. A sanitary station shall consist of at least a trapped four-inch sewer riser pipe connected to the park's sewerage system, surrounded at the inlet end by a concrete apron sloped to the drain, and provided with a suitable hinged cover, and a water outlet, with the necessary appurtenances to permit periodic wash down of the immediate area.
c. No wastewater or other liquid effluent shall be discharged or allowed to accumulate on the ground surface.
4. GFI and weatherproof electrical outlets supplying at least one hundred ten (110) volts, shall be provided at each trailer space. All electrical work shall comply with the regulations of the National Electrical Code.
5. At least one health department approved container for solid waste shall be provided for each trailer space to be rented.
6. Where dependent trailers are to be located, central toilet facilities shall be provided. Central toilets shall be plainly marked, separated by sex, lighted at night, and located within 200 feet of the trailer spaces served. For each ten spaces or every fraction thereof, not less than one commode, one lavatory, and one tub or showerhead shall be provided for each sex. In addition, for each 20 trailer spaces or fraction thereof, at least one urinal shall be provided in each central toilet designated for men.
7. All-weather drives at least 20 feet wide shall be provided to each trailer space within the park.