The requirements of Article 17, Off-Street Parking and Loading, Article 19 for parking lot landscaping requirements, Section 18-4 for lighting, and the Palmetto Sign Ordinance shall apply except as modified by this article.
A. Parking.
1. Intent. The goals of the parking requirements are to:
a. Promote a "park once" environment enabling people to conveniently park and access a variety of commercial and civic uses by encouraging shared parking.
b. Reduce fragmented, uncoordinated, inefficient, single-purpose reserved parking.
c. Avoid adverse parking impacts on neighborhoods adjacent to the form districts.
d. Maximize on-street parking.
e. Increase visibility and access to publicly available parking.
f. Provide flexibility for redeveloping small sites.
g. Promote projects using flexible and creative incentives.
h. Incorporate convenient bicycle parking.
2. Location.
a. Off-street parking shall be located as delineated on the regulating plan and as required in Section 10-4.F., above.
b. These provisions shall not apply to parking areas located forward of the RBL that were in existence at the time this ordinance was adopted. However, an event that triggers conformance with these requirements, as stated in Section 10-10.A., below shall require, at minimum, a streetwall and/or landscape screen to be installed at the right-of-way line or at the RBL.
3. Number.
a. The number of off-street parking spaces provided shall not exceed those enumerated in Table 17-1, Parking Requirements by Use.
b. Fewer parking spaces may be allowed as provided in Section 17-1.D.
c. On-street parking spaces located along the frontage of a property shall be included when calculating parking requirements for a use on that lot. Such spaces shall not be reserved for the exclusive use of patrons or occupants of the lot, but shall be available to the public. A parking space which is contiguous to a lot frontage for less than 50 percent of its length or width shall not be counted toward meeting the parking requirements for that property.
d. A sidewalk dining area associated with an eating or drinking establishment is not subject to the parking requirements in Table 17-1.
B. Exterior Areas.
1. Temporary Outdoor Display Areas.
a. Temporary outdoor displays are permitted, and may be located forward of the RBL or within the C-2 District upon a public sidewalk, but shall be limited to the property in question and located within three feet of the building façade. Access to sidewalks and building entrances shall be maintained so that pedestrian circulation is not impaired.
b. Alternate outdoor display area locations may be approved as long as pedestrian circulation or entrances to a building are not impaired.
2. Other. Space for bike racks, civic art, or other similar uses/activities may be permitted, provided a minimum five foot sidewalk clear area is maintained.
C. Landscaping and Screening.
1. Parking Lots.
a. Parking lots serving multiple family dwellings and non-residential uses that are visible from a public street, sidewalk, or adjacent one or two family residential district or use shall be screened by a streetwall not less than four and no more than five feet in height, constructed at the RBL of the lot. However, the wall must provide a break at intervals no greater than 50 feet to allow pedestrian access.
b. Landscaping of the same height (at planting) may be used if it screens the parking area with at least 75 percent opacity.
c. Parking lots exceeding 15 spaces shall be landscaped to break up large expanses of pavement, provide shade and assist with vehicular and pedestrian flow. At least one landscaped island shall be provided per each ten parking spaces.
d. The location and design of parking lot landscaping shall be approved by the zoning administrator, or the planning and zoning board, as applicable. The number of plants and island requirements shall meet the requirements of Chapter 23.5.27 of the City of Palmetto Code of Ordinances.
2. Trash Enclosures and Other Outdoor Equipment.
a. Exterior trash disposal areas and equipment shall be enclosed by brick, decorative concrete or other material that matches the main building. The enclosure shall be at least six feet high, with three sides and a gate on the fourth side. Outdoor mechanical equipment shall be similarly screened, provided that the enclosure needs to be only as tall as necessary to fully screen the equipment. Trash enclosures used in common by multiple users are permitted.
b. A group enclosure that spans the width of more than one building may be constructed of a uniform material throughout, provided that it is complimentary to the adjoining buildings.
D. Lighting (See Section 18-3 for general requirements).
1. Lighting, if installed, shall be pedestrian-style lighting along all sidewalks, pedestrian walkways within parking areas, and along other pedestrian ways.
2. Pole lighting shall be a maximum of 20 feet high.
3. In the C-2 District, light fixtures not exceeding 30 feet may be permitted for pole lighting if the fixture is located at least 200 feet from the boundary of any residential district or use.
4. All light fixtures or structures shall be architecturally compatible with the building.
E. Public Art. Public art is encouraged and may be located in appropriate areas without regard to setbacks, RBLs, etc., provided that clear vision at corners is maintained.
F. Sign Requirements.
1. R-3A Traditional Residential District and R-3B, Mill Village Residential District. Signs in the R-3A District shall conform to the sign requirements in the Palmetto Sign Ordinance.
2. C-2 Central Business District: Only those signs listed in Table 10-6 shall be permitted in the C-2 District. Except as modified by this article, signs shall comply with the requirements of the Palmetto Sign Ordinance.
Table 10-6. Sign Requirements for the C-2 District Type of Sign Maximum Sign Area Height Location Illumination Number of Signs(1) Awning 1 square foot per linear foot of awning up to a max. of 10 square feet Cannot exceed height of awning Must be located on front of a shed awning External illumination only Max. 1 per awning Institutional bulletin board 24 square feet Max. 6 feet Must be setback min. 5 feet from front lot line External or internal illumination permitted Max. 1 per civic/ institutional building Projecting 3 square feet Below second story windows and min. 8 feet, but no more than 15 feet, above sidewalk, streets and alleys Must be located on the façade of building External illumination only Max. 1 per mixed use or commercial building, but no closer than 18 feet to another projecting sign.
Corner buildings are permitted 1 sign per street frontage Rear entry 15 square feet Max. 8 feet above ground level or sidewalk Must be located on rear or side façade not facing street External or internal illumination permitted Max. 1 per rear entry for mixed use or commercial building Sidewalk or sandwich board(3) 6 square feet 4 feet On sidewalk in front of the business, at least 2 feet from curb Not permitted One per business Type of Sign Maximum Sign Area Height Location Illumination Number of Signs(1) Wall sign:
ground floor uses Ten percent of wall area on which the sign is located and occupied by the use to which the sign refers, up to max. 30 square feet Between the second story floor line and the first floor ceiling within a horizontal band not to exceed two and a half feet in height.
In no case shall this band be higher than 18 feet or lower than 12 feet above the adjacent sidewalk Must mounted to the façade and cannot extend beyond the wall surface more than 12 inches External or internal illumination permitted Maximum 1 per mixed use or commercial building.
Corner buildings are permitted 1 sign per street frontage Wall sign:
upper floor uses 10 percent of front building façade, up to max. 48 square feet Below the cornice of a flat roof building, or roof eave of a pitched roof Must be mounted to the front façade and cannot extend beyond the wall surface more than 12 inches External or internal illumination permitted Maximum 1 per mixed use or commercial building (2) Window No more than 25 percent of surface of window Only permitted on first story windows Not permitted Max. 1 per window on a mixed use or commercial building "Exempt signs" as specified in Table 17-2 Notes to Table 10.6:
(1) Except for a building located on a corner, a single building shall be permitted to have only one of the following types of signs: Awning sign or projecting sign.
(2) Where a single use occupies both the ground and upper floors of a building only one wall sign shall be permitted on either the ground floor or the upper floor façade.
(3) A sidewalk sign shall be removed from the sidewalk and taken inside at the close of business each day. At least 35 percent of the sign area shall be permanently painted or affixed graphics. The remainder may allow for changeable letters (reader board/message board) or handwritten advertisements. The owner of the sign shall provide proof of insurance in the amount determined from time to time by the city council and shall provide proof that the City of Palmetto is an additional named insured on the policy.
3. All new signs and all existing signs, except "exempt signs" that are altered, relocated, replaced, or reconstructed shall be required to obtain a sign permit under the Palmetto Sign Ordinance.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.