A. The proposed heliport and all appurtenant facilities and equipment shall be constructed, operated and maintained in accordance with the published rules, regulations and guidelines of the Federal Aviation Administration and the Georgia Department of Transportation, Aviation Programs Division.
B. The proposed heliport and all appurtenant facilities and equipment shall conform to NFPA Standard 418, Standards for Heliports, 2006 Edition, with the exception that Sec. 9.1.2, exempting certain heliports from the requirement to be equipped with portable fire extinguishers, shall not apply.
Portable fire extinguishers shall be required at all heliports, at a location and stored in a manner approved by the Fire Chief.
C. The use shall be located on a lot having a minimum area of ten acres.
D. The touchdown and lift-off area (TLOF), as defined in Federal Aviation Administration Advisory Circular 150/5390-2B, or any successor advisory circular, shall comply with the following minimum separation distances:
1. From the boundary of any property zoned Light Industrial (M-1I) or Heavy Industrial (M-2):
150 feet.
2. From the boundary of property in any other zoning district: 300 feet.
3. From a building on property, other than property owned by the applicant, zoned Light Industrial (M-1I) or Heavy Industrial (M-2): 200 feet.
4. From a building on property in any other zoning district: 500 feet.
E. A helicopter shall not remain in operation on the ground for a period of time greater than that necessary for startup/shutdown, loading and otherwise essential ground operations (generally no longer than 5 minutes).
F. As a condition of special use approval, the city council may impose limits on:
1. The size and type of rotorcraft permitted to use the facility;
2. The allowable hours of use of the facility;
3. The frequency of helicopter operations permitted at the facility; and
4. The location, design, type, size, and use of any exterior lighting, buildings, fuel storage or other equipment or facilities associated with the heliport.
G. The provisions of this section shall not apply to emergency operations conducted by law enforcement, public safety agencies or emergency medical service providers.