Pearson · Ordenanza de zonificación
Appendix A - ZONING / Article VII - REQUIREMENTS BY DISTRICTS
79.5.7. Lot and Yard Requirements
Sobre este texto
- As published by Municode, current through 2015-08-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
a) Minimum Front and Side Yard on Streets. The front and side walls of the main structure shall be set back from the right-of-way line of the street as follows:
Major Street 50 feet Collector Street 40 feet Minor Street 40 feet
b) Side Yard Not on Street. The side wall of the main structure shall be set back at least thirty (30) feet from the side property line. Wherever a property line abuts a railway right-of-way, this setback requirement may be waived for the sole purpose of providing a facility for direct loading and unloading between railway car and building.
c) Minimum Rear Yard. The rear of the main structure shall be set back at least forty (40) feet from the rear property line. Wherever a property line abuts a railway right-of-way, this setback requirement may be waived for the sole purpose of providing a facility for direct loading and unloading between railway cars and building.
d) In each of the yards (setbacks) described above, no building structure or obstruction shall be erected or maintained on any land abutting within fifteen
(15) feet of the top of the bank of any canal which is part of the Pearson Drainage Canal,, including without limitation, additions, extensions and modifications thereto, and all parts of the Pearson storm water canal system.
e) Maximum Height. No structure shall exceed sixty (60) feet in height, except upon approval of the City of Pearson Fire Department.
f) Planted Buffer. A plant buffer strip is required within setbacks adjoining residential uses and meeting the applicable requirements of Section 610.1.
Such buffer strip shall be composed of and maintained with healthy plants which possess growth characteristics of such a nature so as to provide within five (5) years, a planting screen not less than five (5) feet wide and not less than six (6) feet high.
g) Floor Area Ratio. Maximum floor area ratio, including any parking space within the structure, shall not exceed fifty (50) percent for single-story buildings nor shall it exceed one hundred (100) percent for buildings of more than one story. The ground area occupied by the principal and accessory structures shall not exceed fifty (50) percent of the total zoning lot area.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.