All single-family residences, whether site built or manufactured housing, must meet the following standards:
(A) Structure and design standards:
(1) Corrugated metal or plastic panels are prohibited as roofing materials with the exception of being used as materials for skylights or patio covers.
(2) The exterior wall shall be material similar to traditional site-built housing.
These materials may include clapboards, simulated clapboards such as conventional vinyl or metal siding over a minimum covering of one-half inch exterior wood sheathing, wood shingles, shakes, stucco, brick, brick veneer, concrete block, or similar materials, but shall not include smooth, ribbed, or corrugated metal or plastic panels.
(3) The minimum horizontal dimension of the unit as installed on the site shall be 24 feet in all districts except MH-3 mobile home park district.
(4) All principal structures shall be placed on a permanent foundation. For the purposes of this section, a permanent foundation shall mean a concrete slab, concrete footers, foundation wall, pilings or post construction which complies with the city building code.
(5) In no case shall wheels, any undercarriage or transporter unit be left on any structure.
(6) All units must meet wind loading requirements of Federal Emergency Management Administrator and the International Building Code.
(B) Manufactured home safety standards. For the purposes of public safety, all manufactured homes or other such forms of mobile, modular, or manufactured housing are subject to the following requirements:
(1) Manufactured home stand requirements. Prior to the issuance of a manufactured home relocation permit the owner of the parcel or lot for which the manufactured home is to be placed must have an approved mobile home stand. Such stand must have the following:
a. Street access. Each manufactured home stand shall be provided with access frontage to a width of at least 30 feet to a public or private street or road.
b. Electric power supply. Each manufactured home stand shall be provided with an adequate, properly grounded, waterproofed electrical receptacle with a minimum rated capacity of 100 amps. A properly sized over current device shall be installed as a part of each power outlet as per the International Building Code.
c. Sewerage disposal. Each manufactured home stand shall be provided with the means of disposing of kitchen, bath, and putrescible waste directly into a properly installed and inspected septic tank system or an approved community sewerage collection system.
(2) Manufactured home tie down requirements. All manufactured homes shall be tied down in accordance to this table below unless the manufacturer's installation requirements call for more or the home is to be placed on a lot that is in or adjacent to a flood hazard area.
Length of Manufactured Home (not including draw bar) Minimum Number of Vertical Ties Minimum Number of Diagonal Ties Number of Required Anchors per Home 0 to 40 feet 2 3 6 41 to 60 feet 3 5 10 61 to 84 feet 3 6 12 This table is based on a minimum working load per tie of 3,150 pounds with a 50 percent overload (4,725 pounds total).
a. Multiple-wide manufactured homes shall only be required to have diagonal ties and anchors in accordance with the chart above unless the manufacturer's installation instructions require more.
b. Single section manufactured homes shall have diagonal and vertical ties and anchors in accordance with the chart above unless manufacturer's instructions require more.
(3) Manufactured home siding, stairs, and foundation requirements:
a. All manufactured homes shall have siding materials consisting of either wood, masonry, concrete, stucco, masonite, or metal lap. The exterior siding material shall extend to ground level except that when a solid concrete or masonry perimeter foundation is used, the siding material need not extend below the top of the foundation.
b. Skirting and/or siding must be in place within 30 days from the date the re-location permit is issued.
c. Stairs and landings shall comply with Section 112 - Stairway Construction of the Georgia Building Code and must adhere to the following:
1. The height of the riser shall not exceed 7� inches, and treads, exclusive of nosing shall not be less than nine inches wide.
2. Every tread less than ten inches wide shall have a nosing, or effective protection, of approximately one inch over the level immediately below that tread.
3. The width of the landing shall not be less than the width of the stairways they serve.
4. Every landing shall have a minimum dimension measured in the direction of travel equal to the width of the stairway. Such dimension need not exceed four feet when the stair has a straight run.
5. All stairways having treads located more than three risers above a floor or grade shall be equipped with a handrail not less than 30 nor more than 34 inches above the leading edge of the tread.
6. The minimum width of any stair serving as a means of egress shall be a minimum of 36 inches.
7. If handicapped ramps are added, they must be at least three feet wide and the slope of the ramp shall not exceed one foot for every 12 feet.
(4) Foundation requirements on all manufactured homes are as follows:
a. Supports or piers shall not be more than two feet from the exterior end wall.
b. All grass and organic material shall be removed and the foundation must be placed on stable soil.
c. Cross over wires must be placed between the two halves.
d. All nails or staples shall be removed or sealed.
e. Dryer vents must be vented to the exterior of the manufactured home; not underneath.
(5) Manufactured home development in flood hazard areas. Due to the danger of placing a mobile home in a flood hazard area the following anchor requirements are required if a mobile home is placed on a lot which is located in or adjacent to a flood hazard area as described by the Federal Emergency Management Association [Agency].
Length of Manufactured Home (not including draw bar) Minimum Number of Vertical Ties Minimum Number of Diagonal Ties Number of Required Anchors per Home 0 to 40 feet 2 4 8 41 to 60 feet 3 6 12 61 to 84 feet 3 8 16 This table is based on a minimum working load per tie of 3,150 pounds with a 50 percent overload (4,725 pounds total).
(6) Manufactured home additions and auxiliary structures. Any significant feature added to a manufactured home that was not part of the manufactures' original design is considered to be either an addition or an auxiliary structure.
a. All habitable spaces added to the manufactured home shall be constructed in accordance with the National Manufactured Housing Construction and Safety Standards Act or within the provisions of the Georgia State Building Codes.
b. All auxiliary structures (such as porches, decks, awnings, cabanas, stairs, etc. unless provided and approved by the manufacturer) shall be entirely self-supporting, unless designed and approved by a professional engineer or registered architect. All such structures shall be constructed in accordance with the Georgia State Building Codes.
(C) Temporary use of recreational vehicles on private property for dwelling purposes. No recreational vehicle shall be used for dwelling purposes on any lot in a residential district unless the lot in question is permitted as an RV park.
(D) Build-for-rent communities.
(1) Build-for-rent communities may be permitted in all residential and planned unit development districts upon application for and receipt of a conditional use permit.
(2) Short term rentals shall not be permitted in any residence in a build-for-rent community therein occupied or intended to be occupied by a long-term tenant.
(3) Build-for-rent communities must be managed by a single management company that maintains the development and property in good order with an on-site and staffed office with standard business hours of 9:00 a.m.—5:00 p.m., Monday through Friday. The on-site office shall be a stand-alone building that shall be similar in design and appearance to other buildings within the development.
Historia
(Ord. No. O2024-09.C, § II, 11-4-2024)