Access to any development that is controlled through any means such as gates and guardhouses, shall comply with the following standards. Emergency and “exit only” access points are exempt for these requirements.

1. Gate Width

The clear opening through gates shall be at least two (2) feet wider than the roadway it controls.

2. Vehicle Queuing Distance 1. Residential uses up to 75 units shall have at least 20 feet of vehicle stacking distance. An additional 20 feet of stacking distance shall be provided for every additional 100 units. 2. Vehicle stacking distance for mixed-use and nonresidential uses are determined by the street type, as indicated in Table 9.2-1.

Tabla 1. Esto era una tabla en la fuente. Cada línea es una de sus filas, con sus celdas en orden, separadas por una barra. Una fila puede tener menos celdas que columnas tiene la tabla, así que lea las celdas en orden, no por columna.
  1. Table 9.2-1 Vehicle Stacking Distances
  2. Street Type | Stacking Distance
  3. Local | 70 feet
  4. Collector | 70 feet
  5. Arterial | 100 feet

1. 3. Vehicle stacking distance is measured from the back of the sidewalk, or five (5) feet from the back of curb or edge of street, whichever is closest to the gate. 4. For any controlled access device that opens on a horizontal plane, such as a gate, a minimum of 20 feet of clear width shall be provided unless additional width is required by the City Manager or his or her designee. Such device shall open away from the street right-of-way.

3. Residential Developments

Adequate maneuvering room between the gate and the street shall be provided for a turnaround area for vehicles to exit in a forward motion. The turnaround area shall have a minimum radius of 60 feet to the outside of the turn. The turnaround area is subject to approval as determined by the City Manager or his or her designee.

4. Related Ordinances

In addition to this sub-section, compliance with the Emergency Access Requirements for Gated Communities Ordinance (Part 3, Chapter 7, as amended) is required.