(a) Streetlights shall be provided along all public rights-of-way utilizing decorative light poles and fixtures consistent with the design adopted by the City of Senoia for the overlay.

The light source shall be high-pressure sodium. Streetlights shall be staggered, 150 feet on-center, along both sides of the roadway. This standard shall not apply to Highway 85 or Highway 16.

(b) Lighting in parking areas shall provide area lighting sufficient to achieve a minimum illumination of 2.4 foot-candles of light as measured at grade level and recommended in the IESNA Lighting Handbook.

(c) All building entrances, walks and vehicular access shall be lit.

The following lighting guidelines shall apply:

• Walk and access lighting: 120-Volt Halogen 20 to 50 Watts.

• Architectural and landscape lighting: 120-Volt Halogen 50 to 100 Watts.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 07-05, Art. 9, 12-3-2007)