Off-street loading shall be established in accordance with the following provisions:

(1) Design standards. Where required, one or more off-street loading spaces shall be provided on the same or adjoining premises with the facility it serves, either inside or outside a building. A loading berth shall have minimum dimensions of 12 feet by 35 feet by 14 feet overhead clearance. A loading space need not be full berth but shall be sufficient to allow normal loading of magnitude appropriate to the property served. The city shall determine the sufficiency of loading space, but in no case shall this space or its use hinder the free movement of vehicles and pedestrians over a street, sidewalk or alley.

(2) Required spaces. The number of spaces or area required for a particular use shall be as follows:

Use Required Loading Spaces Retail operations including restaurant and dining facilities with hotels and office buildings, with a total useable 20,000 square feet or more devoted to these purposes.

1 loading berth for every 40,000 square feet area or fraction thereof; 1 loading space for 20,000 square feet of floor area or fraction thereof.

Retail operations, and all first floor nonresidential uses with a gross floor area of less than 20,000 square feet, all wholesale and light industrial operations with a gross floor area of less than 10,000 square feet.

1 loading space Use Required Loading Spaces Office buildings and hotels with total useable floor area of 100,000 squarefeet or more devoted to these uses.

1 loading berth for every 100,000 square feet Industrial and wholesale operations with a gross area of 10,000 square feet or over and as follows:

Minimum Number of Loading Berths Required 10,000—40,000 sq. ft. 1 40,000—100,000 sq. ft. 2 100,000—160,000 sq. ft. 3 160,000—240,000 sq. ft. 4 240,000—320,000 sq. ft. 5 320,000—400,000 sq. ft. 6 Each 90,000 above 400,000 sq. ft. 1 (Ord. No. 07-05, Art. 13, § 13.11, 12-3-2007)