2.4.10. C3—Heavy Commercial District.

Sobre este texto

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
  • Tables are shown as their rows, with the cells separated by a bar ( | ).
  • This section's figures, maps, or images are in the source and are not shown here.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. District Intent. The intent of the C-3 District is to provide distinct areas for commercial activities which provide products and services that require locations along major arterial roads, highway intersections, and freeway interchange areas, due to their generation of heavy traffic or their need to transport and display heavy bulk materials, and which provide services that would not be appropriately located in areas providing neighborhood or other commercial retail and service activities. Uses in this district shall be located on roads having a minimum classification of major arterial.

B. District Standards.

Tabla 1. Esto era una tabla en la fuente. Cada línea es una de sus filas, con sus celdas en orden, separadas por una barra. Una fila puede tener menos celdas que columnas tiene la tabla, así que lea las celdas en orden, no por columna.
  1. LOT DIMENSIONS | YARD SETBACKS | OTHER REQUIREMENTS
  2. Minimum Lot Area: • 10,000 square feet Minimum Lot Width: • 100 Maximum Lot Depth: • None Minimum Lot Frontage: • 100 percent of the lot width | Minimum Front Yard Setback: • 70 feet Minimum Side Yard Setback: • 10 feet • 30 feet for corner lots Minimum Distance Between Buildings: • 20 feet Minimum Rear Yard Setback: • 30 feet | Maximum Lot Coverage: • 70 percent

C. Container-Based Construction Standards.

1. Definitions.

"Container-based buildings" are structures primarily constructed using repurposed intermodal shipping containers that are modified to serve as commercial business facilities. These containers must be adapted to meet all applicable building, safety, and aesthetic standards.

Rail-based buildings" are structures created from repurposed rail cars or locomotives, adapted for use as commercial business facilities.

2. Permitted Use. Container-based buildings shall be permitted within the Downtown Village Overlay District by special use permit, subject to compliance with all applicable building codes, design guidelines, and site plan review requirements.

3. Design Requirements. All container-based and rail-based structures must incorporate architectural treatments that complement the surrounding architectural context, including facade enhancements, landscaping, and pedestrian-oriented design features.

4. Safety Standards. The use of shipping containers, rail cars and locomotives must be structurally sound, weather-resistant, and modified to meet all safety, accessibility, and aesthetic standards established by the city.

a. Container-based buildings and rail-based buildings shall not exceed the height or density limits prescribed for the DV Overlay District and must maintain compatibility with adjacent uses.

b. Be structurally engineered to meet the International Building Code (IBC) and Georgia State Minimum Standard Codes.

c. Include fire-resistant insulation and interior finishes that comply with NFPA standards.

d. Be equipped with proper ventilation, electrical, plumbing, and HVAC systems installed by licensed professionals.

e. Pass inspection for wind resistance, load-bearing capacity, and emergency egress.

f. Be free of hazardous materials, including residual chemicals or coatings from prior container use.

5. Compatibility. Container-based buildings and rail-based buildings shall not exceed the height or density limits prescribed for the DV Overlay District and must maintain compatibility with adjacent uses.

6. The planning and zoning department shall review and approve all container-based and rail-based construction proposals before issuing permits. Container-based buildings and rail-based buildings shall be permitted within the Downtown Village Overlay District subject to compliance with all applicable building codes, design guidelines, and site plan review requirements.

D. Fire Safety Requirements.

1. All container-based and rail-based buildings must include fire-resistant insulation and interior finishes that comply with National Fire Protection Association (NFPA) standards.

2. Buildings must be equipped with automatic fire suppression systems, such as sprinklers, in accordance with local fire codes and the International Building Code (IBC).

3. Emergency egress routes must be clearly marked and accessible, including doors and windows that meet fire safety and accessibility standards.

4. Smoke detectors, fire alarms, and extinguishers must be installed and maintained in accordance with local fire department regulations.

5. All fire safety systems must be inspected and approved by the City of Stockbridge Fire Marshal prior to occupancy.

(Ord. No. OR25-622, 2(Exh. A), 12-8-2025)

| | |-----------------------------------------------------------| | LI—Light Manufacturing District |