A. District Intent. The intent of the Mobile home Residential District is to accommodate mobile home developments as attractive and attainable housing options. Mobile home parks shall be designed in accordance with O.C.G.A §§ 8-2-160 through 168, the State Board of Health requirements, and the requirements of this Code.

It is intended that such mobile home developments shall be so located, designed, and improved as to provide a desirable residential environment, protection from potentially adverse neighboring influences, and access for vehicular traffic without traversing local streets in adjoining residential neighborhoods. Mobile home developments, including mobile home parks and mobile home subdivisions, shall be located on a thoroughfare having the minimum classification of an arterial roadway.

B. District Standards.

Tabla 1. Esto era una tabla en la fuente. Cada línea es una de sus filas, con sus celdas en orden, separadas por una barra. Una fila puede tener menos celdas que columnas tiene la tabla, así que lea las celdas en orden, no por columna.
  1. LOT DIMENSIONS | YARD SETBACKS | OTHER REQUIREMENTS
  2. Minimum Development Area: • 15 acres for park Minimum Lot Width: • 125 feet Maximum Lot Depth: • None Minimum Lot Frontage: • 100 percent of the lot width Minimum Lot Area: • 5,000 square feet with public water and sewer • 18,000 square feet with public water and septic | Minimum Development Front Yard Setback: • 60 feet Minimum Side Yard Setback: • 15 feet Minimum Distance Between Buildings: • 20 feet Minimum Rear Yard Setback: • 40 feet | Maximum Lot Coverage: • 40 percent Minimum Open Space: • 20 percent Minimum Living Area: • 720 square feet Minimum Number of Units: • 50 per development

| | |------------------------------------------------------------| | OI—Office Institutional District |