Title 12 - UNIFIED DEVELOPMENT CODE / Chapter 4 - DEVELOPMENT STANDARDS / 4.3 - Site design standards.

4.3.4. Outdoor lighting standards.

Sobre este texto

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

The intent of this Unified Development Code is to preserve, protect and enhance the lawful nighttime use and enjoyment of all property through use of appropriate lighting practices and systems. Such individual fixtures and lighting systems are designed, constructed and installed to control glare, minimize obtrusive light and conserve energy and resources while maintaining safety, security and productivity, and curtail the degradation of the nighttime visual environment.

A. Establishing Lighting. Lighting in all districts shall be established in a manner that no direct light is cast upon or adversely affects adjacent properties or roadways. This section shall not apply to lighting established by governmental authority within public rights-of-way.

B. Submittal Requirements. The applicant for any permit involving outdoor lighting fixtures governed by this section shall submit, as part of the site plan, evidence that the proposed work will comply with this section. The following information shall be included in all nonresidential site plan submissions and all plans for uses ancillary to residential uses such as clubhouses, amenity areas, etc.:

1. Location, type and height of all freestanding, building-mounted and canopy light fixtures, shall be shown on the site plan and building elevations;

2. Photometric grid overlaid on the proposed site plan indicating the overall light for intensity throughout the site (in foot-candles). No certificate of occupancy or certificate of completion shall be issued until the photometric grid has been approved by the director;

3. Specifications and details for the fixture type being proposed, including the total lumen output, type of lamp and method of shielding;

4. Use of fixture proposed; and

5. Any other information deemed necessary by the director.

C. General Provisions. The design and illumination standards of this Unified Development Code shall apply to all exterior lighting sources and other light sources visible from the public right-of-way or adjacent parcels, except where specifically exempted herein.

1. Shielding. Exterior lighting shall be fully shielded and directed downward, and shall utilize full cutoff housings, louvers, glare shields, optics, reflectors or other measures to prevent off-site glare and minimize light pollution.

2. Intensity. The intensity of light within a site shall not exceed ten (10) foot-candles within any site; however, the director may permit a maximum intensity of twenty (20) foot-candles provided that such lighting is otherwise in compliance with this ordinance and a maximum intensity of one (1) foot-candle is maintained at any property line or street right-of-way line. Where the property abuts a residential district or existing residential use, the intensity shall not exceed one-half (0.5) foot-candle at the property line.

3. Measurement. Light intensity levels shall be measured on the horizontal plane at grade level within the site, and on the vertical plane of any property line or street right-of-way line at a height of five (5) feet above grade level.

4. Decorative Light Fixtures. The director may approve decorative light fixtures as an alternative to shielded fixtures, provided that such fixtures would enhance the aesthetics of the site and would not cause off-site glare or light pollution.

5. Wall-Mounted Lights. Wall-mounted lights shall be cut-off, down directional with a maximum of to four hundred (400) watts per fixture.

D. Exemptions. The following are exempt from the lighting requirements of this section:

1. Roadway and airport lighting and lighting activated by motion sensor devices.

2. Temporary circus, fair, carnival or civic events.

3. Construction or emergency lighting, provided such lighting is temporary and is discontinued immediately upon completion of the construction work or abatement of the emergency necessitating such lighting.

4. Temporary lighting.

5. Lighting associated with agricultural activities.

6. Athletic fields.

7. Swimming pools.

8. Holiday decorations.

9. Shielded pedestrian walkway lighting.

10. Residential lighting with no off-site glare.

11. Street lights.

12. Other uses deemed reasonable by the director.