A. Materials.

1. Pitched roofs shall be limited to architectural dimensional grade asphalt shingles, natural slate, natural terra cotta, natural wood shake, copper or factory finished sheet metal.

2. Exposed metal flashing shall be copper, or factory finished sheet metal. If factory finished metal flashing is used, such as standing seam, the color must be subdued to blend with other materials or of a color to simulate weathered copper or bronze.

3. There shall be roof articulations/offsets at a minimum of one (1) per each one hundred twenty-five (125) linear feet of length by a change in the top line of the parapet. Additional articulation may occur at any lesser distance. If the front facade is less than one hundred twenty-five (125) linear feet of length, then a minimum of one (1) roof articulation must occur.

B. Type.

1. Mansard roofs.

a. Shall have a maximum pitch of 12:12.

b. Shall have a minimum twelve-foot vertical surface length.

2. Flat roofs.

a. Building materials for flat roofs shall meet local codes.

b. All buildings with flat roofs should include parapet articulation on the front facade(s) of such building.

3. Green roofs.

a. Shall be highly recommended and will be reviewed on a case-by-case basis.

4. Canopies.

a. Drive under canopies for gasoline pumps may have flat roof with vertical or factory formed facing of finished sheet metal.

b. Arcade/structural canopy for retail use. For any multi-tenant commercial development, a covered arcade/structural canopy shall be provided along the front facade of the building. It shall be a minimum of five (5) feet in width and designed to provide covered areas for relief from the weather. Different arcade/structural canopy designs may be used for each individual tenant/business within a multi-tenant commercial development provided that they blend aesthetically with the front facade of the building and has the approval of the building owner and the director of community development in the City of Stockbridge.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:stockbridge/zoning/4.4.5@2026-11-14-695d8e95b7

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Stockbridge Zoning Ordinance, 4.4.5. Roof requirements for buildings under twenty thousand square feet | Georgia Commons