A. The applicant shall submit the number of copies of development plans and supporting data and supporting plans as specified by the city.

B. The applicant shall submit two (2) copies of construction improvement plans to the Henry County Water and Sewer Authority (HCWSA).

C. All development plans shall provide the information specified in Section 8.1 and the following information:

1. All information needed to demonstrate compliance with the site design and development standards in this unified development code.

2. Depiction of existing uses in adjacent areas.

3. Draft of proposed deed restrictions to be imposed.

4. Zoning district of the property, including any special conditions of zoning imposed by the mayor and city council.

5. Deed, record names, and addresses of adjoining property owners or subdivisions, along with zoning of the adjacent parcels.

6. Total area in acres and square feet.

7. Any project to be developed in phases shall provide all information for the total site and for each phase.

8. Topographic contours and vertical intervals of not more than two (2) feet when a new street is proposed.

9. Soil conditions according to U.S. Soil Conservation Service Classifications Manual.

10. Proposed density (both gross and net) and lot layout, consistent with the requirements of the future land use map of the comprehensive plan, including lot and block numbers and/or letters. Layout of all lots shall indicate building setback lines, lot dimensions, and lot area. Lots with detention ponds shall meet minimum zoning area requirements outside the area of the detention pond.

11. For mixed use projects, drawing notes shall include a table summarizing the total amount of development in each use, the percentage of the total site, net density of proposed residential development.

12. Location of existing and platted property lines, location, width, and names of all platted roads, railroads, utility rights-of-way, public areas, existing buildings or structures.

13. Show all existing and proposed easements. Show drainage easements for storm drainage pipes that cross individual lots.

14. Protected open space.

15. Depiction of natural features on the site and adjacent areas, including streams, lakes, other water bodies, wetlands, designated groundwater recharge areas, land subject to a one hundred-year flood hazard, including contour elevations, and geologic features, and other protected environmental features, as set forth in Title 16, including an outline of wooded areas, vegetation, and surface drainage, together with information on methods for protection of natural features as required in this unified development code. State if elevations are taken from a surveyed stream on a FEMA map or if the elevations are from an independent study (HEC-2, QUICK-2, etc.). Flood elevations on any lots within a one hundred-year flood hazard area shall be shown. In addition, the foundation elevation that is a minimum of three (3) feet above the established one hundred-year flood evaluation shall be shown. This data may be shown either on the layout or in tabular form.

16. Wetland areas shall be field located. Notation whether live streams and/or wetlands lie within this subdivision, or unit and phase. Provide a copy of wetlands delineation report from a qualified professional with training and experience in wetland delineation following the guidelines of the latest version of the Army Corps of Engineers Wetlands Delineation Manual.

17. Proposed buffers, landscaping, and tree protection. This shall include the location, size, and type of proposed plant materials.

18. Location of proposed buildings to be used for commercial, industrial, recreational or public facility uses.

19. Details regarding other proposed structures or additions to existing structures, including accessory structures and signs.

20. Layout and names of proposed roads, alleys, public walkways/bikeways (i.e., sidewalks, trails, paths, bicycle facilities), with width of pavement and rights-of-way. Total lineal feet of proposed roads (per phase and total) shall be indicated.

21. Construction plans of streets including typical cross-section and grade profiles. Show percent of each grade and length of each vertical curve.

22. Show the centerline stopping distance for all points of access onto public roads and posted speed limits on existing roads.

23. Existing sewers, water mains, drains, culverts and other underground facilities within the tract or within the right-of-way of boundary roads with sizes, grades, and invert elevations from field surveys or other sources. All sizes and data on all utilities shall be provided. Location of proposed public facilities such as sanitary sewers, water mains, storm drainage facilities, culverts, bridges, and other underground or aboveground facilities within the parcel to be developed, or within the rights-of-way of roads bordering the parcel. Sizes, grades and invert elevations from field surveys or other sources, consistent with the requirements of Title 16.

24. Construction plans of sanitary sewers with grades, service, pipe size, and points of discharge and connection to other trunk or lateral sewers.

25. Construction plans of storm drainage systems with pipe sizes, length, grade, location of outlets, runoff and velocity calculations, etc. All storm drainage systems carrying off-site runoff shall be designed for the one hundred-year storm event. All storm pipes within the city right-of-way shall be approved by the city.

26. Construction plans of water supply system with pipe sizes and location of hydrants, valves, and all appurtenances.

27. Final contours. Street profiles may suffice in indicating cut and fill volumes; however, in many cases, final contours must be shown on the plans.

28. Any structural practice used shall be explained and illustrated with detail drawings.

29. Show the following notes on all plans:

a. A twenty-foot wide storm sewer and sanitary sewer easement exists along each property line and along each lot line, centered on lot lines, for future drainage and sanitary sewer lines.

b. All storm drains shall be extended to the rear setback line.

c. Grade stakes shall be set on all streets prior to any street grading. An as-built subgrade centerline profile shall be submitted and approved by [the] city prior to the installation of curb and gutter or waterlines.

d. An as-built detention pond detail and revised hydro study shall be submitted to the city prior to the final approval.

e. All undisturbed buffers shall be field located; staked and flagged or marked with "tenzar" (or similar type fencing); and shall be submitted to the city for approval prior to grading.

D. Applications for development plans within each watershed protection area identified and regulated in Title 15 shall provide the following additional information:

1. The distance of each impervious structure and surface to the nearest bank of an affected perennial stream and reservoir.

2. The location of each perennial stream that crosses or abuts the site.

3. The location of each public reservoir that abuts the site.

4. The location, elevation and orientation of the one hundred-year floodplain on the site.

5. A certification issued by a registered land surveyor or registered engineer verifying the location of the site as being located either within the water quality critical area, the limited development area or outside of the both areas.

6. Location and detailed design of any spill and leak collection systems designed for the purposes of containing accidentally released hazardous or toxic materials.

E. Requirements Regarding Permanent Reference Monuments. Materials, size, and location shall conform to the following:

1. Steel pins not less than one-half (½) inch in diameter and thirty (30) inches long, with a survey marker cap showing the land surveyors registration number shall be set at all lot corners.

2. Resetting monuments. Any monuments disturbed by construction or grading shall be reset by the applicant and approved by the director.

F. Administrative Action.

1. The director shall make a determination of completeness as set forth in subsection 8.3.2.

2. When an application for development plan has been determined to be complete, the application and all accompanying information shall be distributed to all required reviewers.

3. The plan review process shall include a determination of compliance with the regulations of this unified development code by the director and recommendations for any changes necessary to improve the subdivision.

4. If the development plan is determined to be deficient by the director or the HCWSA, it shall be returned to the applicant for revisions.

5. A development plan may be approved with conditions. If the development plan is approved with modifications, the conditions shall be indicated on the plat. A copy of the plat with changes indicated shall be returned to the applicant, who shall have the revisions made by the engineer, surveyor, or landscape architect who prepared the plat before the final plat is submitted for approval.

6. A soil erosion and sedimentation control plan, when in compliance with the standards for erosion and sedimentation control as set forth in Title 15, Section 15.5 shall be approved prior to issuance of a building or development permit to begin construction.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:stockbridge/zoning/8.4.2@2026-11-14-264caf1300

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Stockbridge Zoning Ordinance, 8.4.2. Requirements for development plans | Georgia Commons