A. Code compliance. All signs permitted under this article shall be fabricated, installed and maintained in accordance with all provisions of this article, applicable editions of the Standard Building Code, as amended, and the National Electrical Code, as amended, and applicable to electrified signs. City construction, life safety, zoning and other relevant codes and ordinances shall be applicable to the fabrication, siting and maintenance of all signs and shall be read in harmony with this article.

B. Enforcement and inspection. The building official shall be responsible for enforcing all applicable codes. All signs shall be subject to inspection by the building official from time to time to assess continuing compliance with all applicable codes and ordinances and to ensure that all signs have been fabricated of appropriate and sound materials that will protect the health, safety, and welfare of the public.

C. Sign materials. The base of monument and pylon signs shall be constructed of brick, stone or metal and which base shall have a minimum height of two feet measured from the adjacent grade. The edges and backs of all wall signs shall be fully encased in metal or other noncombustible material. All signs comprised of plastic materials, including copy, facing and display surfaces, shall comply with American Society for Testing and Materials (ASTM) D 65.

D. Sign faces. The display face of a sign shall be flat, with projections of no more than two inches to allow for the texture of the sign and words, letters, figures, symbols, logos, features, colors or other design elements. No sign or other advertising device shall have nails, tacks, wires or other hazards projecting from the face of the sign. Any sign panels shall be finished in a uniform background color and comprised of uniform material. All freestanding signs shall display the numerical property address of non-residential properties having a minimum height of six inches and a maximum height of 12 inches or as required by applicable codes.

E. Electrified signs. All signs fitted with any electrical devices or circuits when illumination is permitted shall display a label certifying approval by Underwriter's Laboratories, Inc. All electrical signs and all electrical devices shall be built in compliance with all applicable building and electrical codes adopted by the city. No sign supplied with electrical power shall be erected within six feet of the projection of any overhead power line downward to the ground.

F. Sign maintenance. All signs, together with all anchors, braces, frames and supports shall be maintained in good repair and safe condition. Signs shall be kept free of excessive rust, corrosion, peeling paint or other surface deterioration. The display surfaces of all signs shall be neatly painted or otherwise treated and properly affixed to the frame and support structure. Signs that are faded, torn, damaged or otherwise unsightly, or in a state of disrepair, shall be repaired or removed within 30 calendar days following written notice from the building official. All signs shall comply with the following requirements:

1. All burned-out bulbs, LED components or other faulty lighting fixtures and damaged sign faces and panels in any existing signs shall be replaced within five business days following written notice from the building official.

2. All sign copy shall be securely fastened to the sign face; all missing copy and sign panels shall be replaced within five business days following written notice from the building official.

3. Signs shall be maintained at all times so as not to be detrimental to public health and safety. Such maintenance includes, but is not limited to, keeping the sign free from faulty wiring, loose fastenings and sharp or otherwise dangerous protrusions.

G. Minimum sign setback.

1. No portion of a sign shall be located less than five feet from the right-of-way from which access to the property is gained.

2. No sign or sign structure of any kind shall be located less than ten feet from a side or rear property line or within a required landscape area or buffer.

H. Ground clearance under signs. Signs over a public or private sidewalk shall be maintained a minimum of eight feet above the sidewalk.

I. Visibility clearance. Any portion of a sign located within 20 feet of the intersection of the right-of-way lines of two or more streets, the intersection of the edge of a driveway and the right-of-way line of a street, or a street intersection with a railroad line shall not exceed 30 inches in height, or be placed less than ten feet above the adjacent grade, nor otherwise obstruct visibility or pose a threat to motorist, cyclist or pedestrian safety.

J. Affixing. No sign shall be erected by nailing, fastening or affixing in any manner to any rock, tree, or utility pole.

K. Free access. No sign shall be erected, relocated or maintained to prevent free access to any door, window, or fire escape; nor shall any sign be attached to any standpipe or fire escape.

L. Supports. No message shall be displayed on any portion of the structural supports of a sign.

M. Site maintenance.

1. The area around all signs shall be maintained clear of trees, shrubbery and other obstacles in a manner to render signs readily visible.

2. Trash or other debris shall not be allowed to accumulate in the area around a sign and all weeds and other undesirable plants shall be eliminated. Such maintenance shall extend to the area within ten feet of the base of the sign.

3. All landscape materials indicated on the approved site plan that do not survive shall be replaced no more than 30 calendar days following written notification from the building official.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 1166, § 1(Exh. A), 4-5-22)