Thomaston · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 98 - ZONING / Article 98-4 - ZONING DISTRICT PURPOSE, USES AND DIMENSIONAL STANDARDS
Sec. 98-4.7. P-I professional-institutional district.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
98-4.7.1. Purpose. The purpose of the P-I professional-institutional district is to accommodate traditional office development in park-like settings and such medical facilities as Upson Regional Medical Center. The comprehensive plan recommends "Office and medical uses" in the medical park character area. Physician and health care offices are accommodated in the P-I district. The plan also cites "improvement of sidewalk and street appearance and amenities of commercial centers; and shared parking arrangements that reduce overall parking needs." The P-I district promotes shared parking to minimize paved areas to achieve such park-like settings and enhance project feasibility.
P-I developments buffer residential uses by affording a transition in development intensity from those more intense commercial uses and the adjacent neighborhood. In addition, reservation of open space is mandated in the P-I district and linking of open space is encouraged to attract quality development and building tenants.
98-4.7.1.1. Permitted uses. The following uses are permitted in the P-I professionalinstitutional district. Any use not specifically named as permitted shall be prohibited.
A. Adult day center.
B. Adult day home.
C. Animal hospitals and veterinary clinics.
D. Artist studios, dance and music schools and other educational facilities.
E. Assisted living facility.
F. Cafeterias and restaurants, provided these uses are operated only in conjunction with hospitals or public buildings, with no exterior evidence of such uses.
G. Child care learning center.
H. Child caring institution.
I. Commercial parking lots and decks.
J. Convalescent home.
K. Electrical transformer or distribution stations, or gas regulator stations, provided such uses are essential for service to the zoning district in which these uses are proposed and provided further that compliance with subsection 98-5.3.2.32 is achieved.
L. Family child care learning home.
M. Funeral homes and funeral services.
N. Health clinics.
O. Hospice.
P. Hospitals and similar medical facilities.
Q. Insurance agencies and offices.
R. Insurance agencies.
S. Massage therapy center.
T. Medical and diagnostic laboratories.
U. Medical clinics.
V. Nursing homes.
W. Offices.
X. Offices of attorneys, accountants, architects, engineers, landscape architects and members of other occupations.
Y. Outpatient medical care centers.
Z. Personal care home, congregate.
AA. Personal care home, group.
BB. Pharmacies.
CC. Places of worship.
DD. Professional offices and medical clinics occupied by physicians, surgeons, dentists or chiropractors and other medical practitioners.
EE. Public buildings, structures, lots and uses.
FF. Public and private schools offering general education courses.
GG. Public buildings and facilities, hospitals and other property and buildings owned or used by hospitals, including non-profit institutions.
HH. Real estate agencies.
II. Specialty shops normally operated in conjunction with hospitals and medical or health clinics, provided such shops are located in the interior of such facilities.
JJ. Tutoring services.
98-4.7.1.2. Accessory uses and buildings. The following uses and buildings shall be allowed in P-I professional-institutional district as accessory to the principal use of the property.
A. Dumpsters and compactors. Refuse facilities shall be located in the side or rear yard and screened to a minimum height of eight feet. Screening materials shall mimic one or more of the building materials used on the primary building.
98-4.7.1.3. Special uses. The following uses may be allowed in a P-I professionalinstitutional district, subject to approval of a special use by city council:
A. Commercial parking lots and parking decks.
B. Halfway houses.
C. Homeless shelters.
D. Temporary shelters.
E. Testing laboratories, excluding medical and veterinary testing.
98-4.7.1.4. Building standards. Such standards as building height, building setback and exterior finish materials shall apply to all development contemplated by this section:
A. Minimum lot area. Minimum lot area shall be one acre.
B. Building setbacks. Minimum building setback shall be 15 feet unless abutting a residential use which shall require a minimum setback from the common property line of 30 feet. Front yard setbacks shall be 40 feet.
C. Maximum building height. Building height shall not exceed 35 feet, unless approved by the fire chief. In no event shall building height exceed 60 feet.
D. Building exterior finish materials. Building exterior finish materials in all nonresidential construction shall consist of full-sized brick, steel, glass, natural wood, natural stone, true hard-coat stucco, and fiber cement siding (Hardie board). Synthetic finishes complying with "Dryvit" standards and acceptable to the city may be allowed. Other materials similar in appearance and composition to the above materials may be used, subject to approval by the building official. Concrete block, synthetic stucco, plywood, T1-11 wood siding, Masonite, particle board, non-cement composite board and any siding materials found to lack durable characteristics shall be prohibited.
Historia
(Ord. No. 1166, § 1(Exh. A), 4-5-22)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.