The following standards shall apply to all new construction, including building additions, provided that standards applicable to such construction in the downtown district are found in article 6, architectural design standards.

98-5.2.1. Single family dwellings. Single family dwellings shall meet or exceed the following minimum standards:

A. The minimum building dimension shall be 24 feet.

B. Minimum heated floor area shall be as required for detached dwellings by the zoning district in which the dwelling is located.

C. The dwelling roof shall have a minimum pitch of 4:12, and shall be covered with asphalt shingles, concrete or clay roof tiles, wood shingles or shakes, metal or similar materials designed and fabricated for roofing.

D. Building exterior finish materials shall consist of full-sized brick, natural wood, natural stone, cement composite stone, true hard-coat stucco, fiber cement siding (Hardie board) and vinyl siding. Vinyl siding shall have a minimum, nominal thickness of 0.04 inches and shall be installed according to the manufacturer's specifications. Synthetic finishes complying with "Dryvit" standards and acceptable to the city may be allowed. Other materials similar in appearance and composition to the above materials may be used, subject to approval by the building official. Metal siding, concrete block, synthetic stucco, plywood, T1-11 wood siding, Masonite, particle board, non-cement composite board and any siding materials found to lack durable characteristics shall be prohibited.

E. The dwelling shall be attached to a permanent masonry or concrete foundation, fully enclosed around the dwelling from grade to the bottom of the first floor of the dwelling.

F. The dwelling shall be permanently equipped with gutters and downspouts.

G. A minimum roof overhang of six inches shall be provided around the entire exterior perimeter at the eave of the roof.

H. All lap siding shall have a maximum width of eight inches per lap.

I. A masonry or wooden landing shall be provided at each exterior door having minimum dimensions of 36 inches by 48 inches.

J. Site-built buildings shall be constructed according to standards established by the Thomaston building codes, as amended from time to time. Industrialized buildings, modular and factory-built buildings shall comply with all applicable state standards and shall bear a decal as evidence of such compliance.

K. The dwelling shall not be a mobile home or a manufactured home.

98-5.2.2. Manufactured homes. Manufactured homes shall meet or exceed the following standards:

A. Manufactured home, class II is a single family dwelling unit meeting the requirements of a manufactured home class I and, in addition, bearing the insignia of the Southern Standard Building Code Congress International.

B. Such dwelling units are transportable in one or more sections, each having a minimum width of ten feet, built on a permanent chassis, designed to be used as a dwelling unit with or without a permanent foundation and designed to be attached to required utility systems and containing electrical, heating, air conditioning and plumbing systems.

98-5.2.3. Accessory buildings. An accessory building is a building detached from the principal dwelling, the use of which is incidental and subordinate in area, extent and purpose to the primary use of the property. Accessory buildings may be accessory to a residential use or to a non-residential use. Accessory buildings shall comply with the standards of this section and all other applicable standards of this chapter.

98-5.2.4. Residential accessory building standards. The following standards shall apply to detached accessory buildings on property developed in residential use:

A. No residential accessory building shall have a ground floor area greater than that of the principal dwelling provided that a common garage having a maximum of eight vehicle stalls may be allowed in the C-TH condominium-townhouse and the M-R, multifamily residential districts.

B. Accessory buildings, including detached garages, shall be permitted in the ES Estate subdivision district—Class one, ES estate subdivision district—Class two, R-1 low density residential district, R-2 medium density residential district, the C-TH condominium-townhouse district and the M-R, multifamily residential district.

C. One accessory building shall be allowed on a residential lot having an area of 9,000 square feet or less. A second accessory building shall be allowed on a lot having an area of 15,000 square feet, but less than one acre, and a third accessory building shall be allowed on a lot having an area of one acre or more. A detached carport having the capacity to shelter one passenger vehicle shall be allowed on any residential lot provided such carport shall be used in determining the allowable number of accessory buildings, and provided further that a carport having a capacity to shelter one passenger vehicle shall be allowed on any residential lot in addition to one accessory building.

D. The maximum size of an individual accessory building on a lot having an area of 9,000 square feet or less shall be 288 square feet. The maximum size of an individual accessory building on a lot having an area of 15,000 square feet, but less than one acre shall be 576 square feet. The maximum size of an individual accessory building located on any residential lot having an area of one acre or more shall be 720 square feet. The combined area of all accessory buildings on a lot having an area of one acre or more shall be 864 square feet. Table 5.1, maximum number and area of accessory buildings, summarizes this information.

E. Duplex, triplex, and quadruplex properties shall be limited to one accessory building per dwelling unit and having a maximum floor area of 288 square feet.

Table 5.1 Maximum Number and Area of Accessory Buildings Lot area (in square feet) Maximum number of accessory buildings Maximum combined area of accessory buildings 9,000 or less 1 288 square feet 15,000 square feet, < one acre 2 720 square feet One acre or more 3 864 square feet

F. Accessory building placement.

1. Located on a lot with a principal dwelling. Accessory buildings shall only be located on the same lot as the principal dwelling to which it is accessory, and shall only be allowed in a side or rear yard, provided that garages in an ES estate subdivision—class two district may be located in a front yard, subject to the setbacks applicable to the principal dwelling.

2. Side and rear yard setbacks. Accessory buildings shall maintain a minimum side and rear yard setback equal to 50 percent of the minimum setbacks applicable to the principal dwelling.

3. Setback on corner lot. Accessory buildings on a corner lot shall comply with the setback for the principal dwelling. No accessory building on a corner lot that adjoins the side yard of a lot occupied by or zoned for a residential use shall be located within 25 feet of the rear property line. This 25-foot setback shall not be required when the adjoining yard is a rear yard.

4. Distance from dwelling and other accessory buildings. All accessory buildings shall be located a minimum of ten feet from the principal dwelling or other accessory buildings on the lot and a minimum of ten feet from the principal dwelling or accessory buildings on adjacent lots. This distance shall be measured from outside wall to outside wall.

G. Accessory building height.

1. No accessory building shall exceed a height of 24 feet as measured from the average adjacent grade at the front of the accessory building to highest point of the roof of the accessory building or the height of the principal dwelling as measured from the average adjacent grade at the front of the principal dwelling to the highest point of the roof of the principal dwelling, whichever is less.

2. No accessory building shall be a full two-story building, provided an accessory building may be one and one-half story.

H. Architectural character and exterior finish.

1. The exterior finish and color of all accessory buildings and structures shall be similar to the exterior finish and color of the principal dwelling on the lot. In the case of brick dwellings, the exterior finish of an accessory building shall mirror the trim work or other siding materials of the principal dwelling and shall consist of materials intended for use as siding.

2. Roof pitch and style, whether gable, hip, or mansard, shall be similar to the roof pitch and style of the principal dwelling. Shed and flat roofs shall be prohibited.

3. Upper level access. Where applicable, access to an upper level of an accessory building shall be located within the interior of the ground floor area of the accessory building.

I. Limitation on use.

1. Accessory buildings shall not be used for residential occupancy, provided that an accessory dwelling unit (ADU) may be allowed, subject to the standards for ADUs found in subsection 98-5.2.6. Accordingly, all other accessory buildings shall not be fitted with potable water or sanitary sewer connections and shall not be equipped with any bathroom or kitchen appliances or fixtures.

2. Accessory buildings on residentially zoned properties shall not be used for any commercial operation whether permanent, part-time, or temporary, provided that a home occupation may be operated within an accessory building.

J. Miscellaneous accessory structures. Outdoor cooking facilities, gazebos, arbors, pool houses and equipment shelters, fireplaces, and waste receptacle enclosures shall be exempt in calculating the maximum number of accessory buildings on a lot.

However, such structures shall be subject to the accessory building setback standards and shall not exceed a combined area of 288 square feet.

K. Permitting schedule. Occupancy of an accessory building to follow occupancy of the principal dwelling. Building permits for a principal dwelling and an accessory building may be issued concurrently. However, no certificate of occupancy for an accessory building shall be issued prior to issuance of a certificate of occupancy for the principal dwelling.

L. Construction standards.

1. All accessory buildings shall comply with the International Building Code (ICC), the International Residential Code for One- and Two-Family Dwellings

(ICC) adopted by the city as provided in chapter 18, buildings and building regulations, section 18-27, adoption of construction and technical codes.

2. Section 50-26, adoption of life safety codes, shall also apply to accessory buildings.

M. Prohibited accessory buildings. Manufactured homes, mobile homes, shipping containers, freight trailers, box cars, trailers or any other structure or vehicle not originally fabricated for use as an accessory building shall be prohibited.

98-5.2.5. �Attached� accessory building standards.

A. When an accessory building is attached to the principal dwelling by a breezeway, passageway or similar means, the accessory building shall comply with the setback applicable to the principal dwelling on the lot. An attached garage or accessory building must share a common wall with the principal dwelling that is a minimum of 50 percent of the wall length of the dwelling or 12 feet, whichever is greater, to qualify as an attached garage or attached accessory building, thereby eliminating the need for compliance with the detached accessory building standards of this section.

Such common wall shall be an integral part of the principal dwelling. An attached garage or accessory building shall comply in all respects with the standards applicable to the principal dwelling.

B. Upper level access. Where applicable, access to the upper level of an attached accessory building shall be located within the interior of the ground floor area of the accessory building.

C. Prohibited accessory buildings and structures. Manufactured homes, mobile homes, freight trailers, box cars, trailers, shipping containers or any other structure or vehicle not originally fabricated for use as an accessory building shall be prohibited.