(a) Minimum cluster housing group site size shall be three acres.
(b) The minimum development standards for individual lot size, width and depth shall not apply if modifications or variations from these standards are shown on an approved site plan. Building setbacks may also be modified or varied except for the following:
(1) Within the A, R-1A, R-1B, and R-1 districts:
a. Buildings shall set back 25 feet from any street right-of-way.
b. Within a cluster housing development, the rear of a cluster housing dwelling unit will have no setback requirement and the sides of a cluster housing dwelling unit will have no setback requirement for one side only; provided, however, that every cluster housing dwelling unit shall have at least one side with a setback of at least 15 feet from another cluster housing dwelling unit. In addition, a cluster housing dwelling unit shall have a side setback of at least 15 feet and a rear setback of at least 40 feet from the property line of any adjacent property that is not developed as a part of the cluster development.
(2) Within the R-2A, and R-2 districts:
a. Buildings shall set back a minimum of 15 feet from any street right-of-way.
b. Side setbacks for cluster housing dwelling units from the perimeter property boundary shall be as follows:
1. For a cluster group of four or less dwellings: eight feet each side;
2. For a cluster group of five or more dwellings: 15 feet.
c. The rear of any cluster housing development unit shall have a rear setback of at least 25 feet from the property line of any adjacent property that is not developed as a part of the cluster housing development.
d. Otherwise, in such districts and within a cluster development, a cluster housing dwelling unit shall have no rear setback requirements and the sides of a cluster housing dwelling unit will have no setback requirement for one side only; provided, however, that every cluster housing dwelling unit shall have at least one side with a setback of at least 15 feet from a side lot line.
(c) Maximum building height: 35 feet.
(d) Maximum land coverage:
(1) Within the A, R-1A, R-1B, R-1, R-2A, and R-2 districts, maximum land coverage shall be the same as the maximum building lot coverage listed within the development standards of the residential district, calculated by dividing the total ground coverage of the several buildings within a cluster housing development by the total lot area of the several lots and the common open space.
(2) No more than 60 percent of the gross land area may be covered by impermeable surfaces including, but not limited to, buildings, off-street parking and drives, tennis courts, and the like, nor by swimming pools and drainage facilities. On the remaining 40 percent of the gross land area, permeable surfaces may be contained within either individual building lots or common areas or within a combination of the two areas. Detention facilities meeting the following criteria may be used to help achieve the 40 percent permeable surface requirement:
a. The maximum depth of the detention facility shall not exceed 2½ feet below the existing ground elevation measured beneath the rim of the depression.
b. The detention facility shall be designed and constructed to drain completely after each rain event.
c. The detention facility shall be designed and constructed with a minimum of three to one side slopes.
d. The detention facility shall be grassed or sodded.
e. Any other unique detention facility that is designed to be usable and maintained for recreation or landscaping features or both may be used to meet the 30 percent permeable surface requirement if approved by the city council to meet this intent. In addition, each two square feet of existing or natural water surface or both or periodically flooded (based on the 100-year flood contour elevation) or inundated land may be credited as one square foot of land area to meet the 30 percent permeable surface requirement.
(e) To preserve the integrity of the surrounding area, the city council may require certain screening buffers as part of the new development, all as provided for elsewhere in this chapter.
(f) All cluster housing developments shall be designed so that no separate dwelling unit will be constructed on top of another separate dwelling unit.
Historia
(Code 1991, § 22-234; Ord. of 12-23-1996(3), § IX)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.