(a) Primary entrances.

(1) The primary entrance of every principal building giving access to a principal use of the property must directly face a street or a public space. Public space may include a central garden or courtyard when that public space opens directly onto the primary street.

(2) Buildings shall be designed and oriented with an emphasis on the primary street on which they front.

(3) Buildings located on corner lots shall use design elements that emphasize the importance of both streets.

(4) The primary public entrance shall be prominently located, easily identifiable, relate to the human scale, and contribute to the overall design intent.

(5) The primary public entrance for commercial buildings shall be at grade or seamlessly integrate required handicap accessibility into the design of the building.

(b) Entry/exit doors. Public entry and exit doors which swing outward shall be recessed into the facade a minimum of three feet where the sidewalk abuts the building.

(c) Window and door openings. Windows and doors shall be vertically proportioned or subdivided to appear vertical.

(d) Columns/posts.

(1) Columns and posts shall not be spaced further apart than they are tall.

(e) Material changes.

(1) When materials are combined on a building facade horizontally, heavier materials should occur below lighter materials.

(2) For buildings of three stories or more, the ground floor should be differentiated from those floors above in order to reinforce the pedestrian space.

(3) Changes from one material or color to another along the horizontal direction should occur at "inside corner" transitions.

(4) Changes in material or color along the vertical direction should occur at a hard-edge "bump-out" transition which gives materials a surface to terminate into.

(5) Façades with an overabundance of different materials or colors are generally discouraged.

(f) Brick and masonry detailing.

(1) Headers.

a. All openings in masonry construction shall be spanned by a header.

b. Permitted header forms shall be the lintel, arch, and jack arch.

c. Headers shall be a minimum of four inches in height and shall be slightly wider than the opening they span.

(2) Sills.

a. All window and door openings in masonry construction shall have a sill at their base.

b. Sills shall be generally rectangular in form, and slope slightly away from the opening to shed water.

c. Sills shall be a minimum of two inches in height and should project from the wall surface a minimum of one-half inch beyond the vertical casing. Sills shall be slightly wider than the opening, the same as the header.

(3) Caps.

a. A cap shall protect the tops of all masonry structures exposed to the weather including: garden walls, stair treads, planter edges, parapets, and freestanding piers.

b. Caps shall be comprised of stone, cast stone, brick, concrete, or slate.

c. The edges of caps may be rectangular, or may be more ornate.

d. Caps shall project past the edge of the masonry structure below by a minimum of one-half inch.

(g) Wide buildings.

(1) The primary façade of buildings wider than 150 feet shall be varied with a change of architectural expression.

(2) These changes in expression may be a vertical element running from the ground plane to the roof, a change in fenestration, color, or texture, or a break in building façade plane or roof line.

(3) These changes may be subtle or significant, but should soften the visual effect of very wide buildings directly across the street from narrower buildings and in general, continue the rhythm of the existing buildings.

(h) Façade transparency. All building façades that face onto a street (including secondary or side streets) or public space shall meet the minimum transparency requirements outlined below. The percentage of transparency per story shall be calculated within the area between finished floor and finished ceiling and shall be a total percentage of doors and windows along that portion of the façade. An example of appropriate façade transparency is shown in the figure below.

(1) Buildings with shopfront.

a. Minimum building façade transparency for ground story: 60 percent and should allow a view of at least five feet of interior space.

b. Minimum building façade transparency for upper stories: 40 percent.

(2) Buildings without shopfront.

a. Minimum building façade transparency for ground story: 30 percent.

b. Minimum building façade transparency for upper stories: 20 percent.

Figure 3-1: Façade transparency requirements for buildings with shopfront.

Figure 3-2: Façade transparency requirements for buildings without shopfront.

(i) Building elements.

(1) Small footprint towers/cupolas.

a. These features are designed to extend above the roof line, and are generally intended to be visual landmarks. They are commonly placed at terminate vistas.

b. Towers/cupolas with a footprint smaller than 650 square feet may extend up to one story above the designated height limit.

c. All tower/cupola heights shall comply with FAA height regulations.

(j) Appurtenances and encroachments. Appurtenances are structural or architectural elements, such as balconies, bay windows, awnings, and other frontage elements that extend from the primary mass of the building. Requirements and standards for encroachments are provided in the transect zone standards and the frontage type standards.

Overhead encroachments are encroachments that extend into the right-of-way but do not meet the ground. Overhead encroachments are permitted within the right-of-way by right with a minimum clearance of seven feet six inches above the sidewalk.

All encroachments that have an element that meets the ground must enter into a right-of-way agreement with the city.

(1) Balconies.

a. The minimum balcony depth is six feet measured perpendicular to the wall face.

Balconies may be inset either partially or wholly within the main body of the building.

b. The minimum underside clearance of a first floor balcony is ten feet.

c. Balconies may occur forward of the build-to line or zone, and may encroach within the right-of-way with special easement permission, but shall not extend closer than two feet from the curb line.

d. Balconies shall be permitted to have roofs, but are required to be open, unconditioned parts of buildings.

e. Balconies must be visually supported from below by brackets or another structurally implicit mechanism, from above by suspension cables or chains, or adjacent side walls (if the balcony is set completely within the main body of the building).

f. On corners, balconies shall be permitted to wrap around the side of the building facing the adjacent street.

Figure 3-3: Examples of Small Footprint Towers/ Cupolas Figure 3-4: Balcony Example

(2) Awnings or canopies.

a. The minimum awning depth for a first floor awning is five feet measured perpendicular to the wall face.

b. The minimum underside clearance of a first floor awning is eight feet.

c. If a building facade has awnings, they shall occur for at least 25 percent of that facade.

d. Awnings may occur forward of the build-to line or zone, and may encroach within the right-of-way, but shall not extend closer than two feet to the curb line.

e. Awnings shall be made of durable fabric and may be either fixed or retractable.

High-gloss or plasticized fabrics are prohibited. Backlit awnings are also prohibited.

(3) Marquees.

a. Marquees may occur forward of the build-to line or zone, and may encroach within the right-of-way, but shall not extend closer than two feet from the curb line.

b. Marquees must meet the sign requirements.

(k) Frontage types. Frontage elements are semi-private elements of the building located in the area between the primary facade and the lot line. Frontage elements may occur forward of the build-to zone or setback. Frontage elements create the transition between the public building and the private or commercial buildings.

Building frontages shall conform with the basic frontage types and the basic standards for those elements. The illustrations and photographs provided are for illustrative purposes.

(1) Shopfront.

a. Description. The front façade of the building is at or near the frontage line. The entrances to all shopfronts shall be covered, either by an awning, canopy, marquee, second floor balcony, arcade, colonnade, or by being inset into the main body of the building.

b. Size.

Distance between glazing 2' max. $ Door recess1 5' max.

Habitable space depth 15' min.

Window sill height 3' above sidewalk max.

Shopfront window 8' min. above sill 1 A recessed entry may be designed in a variety of configurations (recessed door, sawtooth pattern, etc.) and may be located on the front facade or the corner of a building. An exception to meet ADA ramp compliance between sidewalk height and inside finished floor is permitted.

c. Miscellaneous.

Doors may be recessed as long as front façade is at BTZ.

Open ended awnings and operable awnings are encouraged.

Rounded and hooped awnings are discouraged.

Folding or garage doors that open and close a restaurant or retail space to the street are permitted in place of shopfront windows. Such doors shall extend from the adjacent sidewalk to at least eight feet above the adjacent sidewalk.

Shopfronts shall have a cornice or expression line between the first and second story.

Shopfront windows may not be made opaque by window treatments (excepting operable sunscreen devices within the conditioned space and window signs).

Shopfront windows should be transparent to be able see into the space inside.

Shopfront doors shall contain at least 60 percent transparent glass. Solid doors are prohibited.

Figure 3-5: Examples of shopfronts and details

1. Shopfront with a recessed doorway

2. Shopfront with metal canopy

(2) Gallery/arcade.

a. Description. The front façade of the building is at the build-to-zone and the gallery/arcade element overlaps the sidewalk, eliminating the need for an awning or canopy. This frontage type is intended for buildings with ground-floor commercial or retail uses and may be one or two stories in height.

b. Size.

Depth, clear 10' min. $ Ground floor height, clear 10' min.

Upper floor height, clear 9' min. � Height 2 stories max.

Setback from curb 2' min. � Length 75% of façade width min. �

c. Miscellaneous.

Galleries/arcades must also follow all the rules of the shopfront frontage type. � Galleries/arcades shall be supported by columns, piers or arches. Support columns can be spaced no farther apart than they are tall.

Galleries/arcades shall occur forward of the build-to zone or setback and may encroach within the right-of-way with the approval of the city. When an arcade extends over a public sidewalk, the property owner may be required to enter into a right-of-way agreement, in a form acceptable to the city, establishing the property owner's sole responsibility for repairing any damage that may result from public maintenance or improvements.

Galleries/arcades shall not extend closer than two feet from the curb line, nor farther than five feet from the curb line.

Enclosed usable space shall be permitted above the galleries/arcades, and within the right-of-way with the approval of the city.

On corner lots, galleries/arcades may wrap around the side of the building facing the secondary street.

Figure 3-6: Example of galleries

1. Gallery with slender metal columns

2. Wood framer Gallery

3. Masonry Arcade with Habitable Space on the second floor

(3) Forecourt.

a. Description. The primary portion of the building's front façade is at the build-tozone while a small percentage is set back, creating a courtyard space. This space can be used as an apartment or office entry court, garden space, or for restaurant outdoor dining.

b. Size.

Width, clear 12' min. $ Depth, clear 12' min.

c. Miscellaneous. Forecourts are especially useful along larger, more auto-dominant streets in order to provide well-shaped, intimately sized public outdoor spaces. The proportions and orientation of courtyard spaces must be carefully considered for solar orientation and user comfort.

Figure 3-7: Examples of Forecourts

1. Elevated Forecourt

2. Elevated Forecourt forming a dining terrace

(4) Stoop.

a. Description. The front façade of the building is at the build-to-zone and the elevated stoop projects forward. The stoop is used to access a first floor that is elevated above the sidewalk to ensure privacy within the building.

b. Size.

Width, clear 4' min., 8' max. $ Depth, clear 4' min., 8' max.

Height, clear 8' min. � Height 1 story max.

Finish floor level above sidewalk 24" min.

c. Miscellaneous.

A stoop is appropriate for residential uses with small setbacks.

Stoops may extend forward of the build-to-zone or setback line and, if permitted by the district standards, into the right-of-way.

A six-foot minimum clear zone for pedestrians shall be maintained on the sidewalk.

Stairs may be perpendicular or parallel to the building facade.

The entry doors are encouraged to be covered or recessed to provide shelter from the elements.

Figure 3-8: Examples of stoops

1. Unroofed stoops

2. Covered stoops

(5) Porch.

a. Description. The main facade of the building is at the build-to-zone and the elevated porch projects forward. The porch is used to access a first floor that is elevated above the sidewalk to ensure privacy within the building. A porch is large enough to function as an outdoor living space.

b. Size.

Width, clear 10' min. $ Depth, clear 8' min.

Height, clear 8' min. � Height 3 stories max.

Finish level above sidewalk 24" min.

c. Miscellaneous.

Porches may extend forward of the build-to-zone or setback line and, if permitted by the district standards, into the right-of-way.

A six-foot minimum clear zone for pedestrians shall be maintained on the sidewalk.

Stairs may be perpendicular or parallel to the building façade.

Figure 3-9: Examples of Porches

1. 2-Story Porch on an apartment building

2. Covered wraparound porch located close to the sidewalk

(6) Common yard.

a. Description. The front façade is set back substantially from the frontage line with a planted frontage. The front yard created remains unfenced and is visually continuous with adjacent yards, supporting a common landscape.

b. Size.

Build to zone See transect zone standards $