(a) Small house.

(1) Building type. This building type is a compact, detached structure on a small lot that incorporates one unit. This type allows for appropriately-scaled, well-designed higher density housing within a primarily single-family, walkable neighborhood. While residential in form, this building type is also appropriate for low intensity retail, service, and office uses, and is often located near, or even on a neighborhood main street.

Small House

(2) Lot.

Lot area No minimum.

Lot width 35-foot minimum; 50-foot maximum.

Build-to line locations Corner lots 0—10 feet from front property line.

0—10 feet from side street property line.

Interior lots 0—15 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 30—80 percent of lot frontage.

Building coverage 50 percent maximum.

Dwelling area 600 square foot minimum.

(3) Height.

Building Height Main building: 2½ stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor Residential: 12-foot maximum.

Nonresidential: 10-foot minimum, 12-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2 feet above grade minimum.

On the north side of Victoria Place St.

(2-foot—3-foot minimum) above grade, as determined by the zoning administrator.

5 feet above grade maximum.

(4) Required frontage. Buildings are required to have either a front or side porch (may be waived and replaced by a stoop with approval by the city planner).

(5) Use. This building type/lot may house all permitted uses in the VPO as defined in section 22-626 (uses); except: dwelling, two-family and multifamily; personal care home, family and group;

live-work townhouse; corner store; and uses specific to landmark buildings.

(b) Medium house.

(1) Building type. This building type is a medium-sized detached structure on a moderate-sized lot that incorporates one unit. It is typically located in a walkable single-family residential neighborhood, potentially near a main street. While primarily used for single-family housing, this type is appropriate for bed and breakfast lodging, as well as low intensity group living, offices, and services.

Medium House

(2) Lot.

Lot area No minimum.

Lot width 45-foot minimum; 70-foot maximum.

Build-to line locations Corner lots 0—10 feet from front property line.

0—10 feet from side street property line.

Interior lots 0—15 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 30—80 percent of lot frontage.

Building coverage 50 percent maximum.

Dwelling area 900-square foot minimum.

(3) Height Building height Main building: 2½ stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story height Ground floor Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2 feet above grade minimum.

On the north side of Victoria Place St.

(2-foot—3-foot minimum) above grade, as determined by the zoning administrator.

5-foot above grade maximum.

(4) Required frontage. A front or side porch is required (may be waived and replaced by a stoop with approval by the city planner).

(5) Use. This building type/lot may house all permitted uses in the VPO as defined in section 22-626;

except: dwelling, two-family and multifamily; personal care home (group); live-work townhouse; corner store; and uses specific to landmark buildings.

Note: Where existing adjacent buildings are set behind the required build-to line, the building may be set to align with the facade of the front-most adjacent property.

(c) Large house.

(1) Building type. This building type is a large, detached structure on a large lot that incorporates one unit. It is typically located within a primarily single-family neighborhood in an urban setting. While primarily used for single-family housing, this building type is appropriate for bed and breakfast lodging and low intensity group living.

Large House

(2) Lot.

Lot area No minimum.

Lot width 65-foot minimum.

Build-to line locations Corner lots 10—20 feet from front property line.

10—20 feet from side street property line.

Interior lots:

0—25 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 40—70 percent of lot frontage.

Building coverage 50 percent maximum.

Dwelling area 1,200-square foot minimum.

(3) Height.

Building Height Main building: 2½ stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor:

Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2 feet above grade minimum.

On the north side of Victoria Place St.

(2-foot—3-foot minimum) above grade, as determined by the zoning administrator.

5 feet above grade maximum.

(4) Required frontage. Buildings are required to have either a front or side porch (may be waived or replaced by a stoop with approval by the city planner).

(5) Use. This building type/lot may house all permitted uses in the VPO as defined in section 22-626;

except: dwelling, two-family; dwelling, multifamily; live-work townhouse; corner store; and uses specific to landmark buildings.

Note: Where existing adjacent buildings are set behind the required build-to line, the building may be set to align with the facade of the front-most adjacent property.

(d) Mansion apartment house.

(1) Building type. This building type consists of three to twelve side-by-side and/or stacked dwelling units, typically with one shared entry or individual entries along the front. This type has the appearance of a large-sized family home and is appropriately scaled to fit within a single-family medium-density neighborhood. This building type is critical to the effort to provide a broad choice of housing that promotes walkability. While residential in form, this building type may be appropriate for group living.

Mansion Apartment House

(2) Lot.

Lot area No minimum.

Lot width 65-foot minimum.

Build-to line locations Corner lots 0—15 feet from front property line.

0—15 feet from side street property line.

Interior lots 0—20 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 50—75 percent of lot frontage.

Building coverage 50 percent maximum.

Dwelling area 1,500 square foot minimum.

(3) Height.

Building Height Main building: 2 stories minimum, 3 stories maximum; except C-2 where the maximum height shall be 4 stories.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2 feet above grade minimum; except ground floor lobbies and common areas in multi-unit buildings may have a 0-inch—6-inch minimum.

5 feet above grade maximum.

(4) Required frontage. Buildings are required to have either a front or side porch (may be waived and replaced by a stoop with approval by the city planner).

(5) Use. This building type/lot may only house multifamily units and personal care homes as defined in section 22-626.

(e) Duplex.

(1) Building type. This building type consists of two side-by-side or two stacked dwelling units, both facing the street. The duplex is properly scaled and designed to appear as a moderate to large single-family home, allowing for the introduction of medium density housing within a primarily detached single-family neighborhood. This type is important for providing a broad choice of housing options that promote walkability. While residential in form, this building type is appropriate for low intensity retail, service, and office uses.

Duplex

(2) Lot.

Lot area No minimum.

Lot width 35-foot minimum.

Build-to line locations Corner lots 0—10 feet from front property line.

0—10 feet from side street property line.

Interior lots:

0—15 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 30—80 percent of lot frontage.

Building coverage 50 percent maximum.

Dwelling area 1,200 square foot minimum.

(3) Height.

Building Height Main building: 2½ stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2 feet above grade minimum.

On the north side of Victoria Place St. (2-foot— 3-foot minimum, above grade), as determined by the zoning administrator.

5 feet above grade maximum.

(4) Required frontage. Entry frontage for each unit shall have a porch (may be replaced by a stoop with approval by the city planner).

(5) Use. Where the underlying zoning is R-2, this building type/lot may only house two-family dwellings as defined in section 22-626. Otherwise, this building type/lot may house all permitted uses in the VPO as defined in section 22-626; except: dwelling, single-family and multifamily;

live-work townhouse; corner store; and uses specific to landmark buildings.

(f) Townhouse.

(1) Building type. This building type is a small to medium-sized attached structure that consists of three to eight dwelling units placed side-by-side. This type is typically located within mediumdensity neighborhoods or in a location that transitions from a primarily single-family neighborhood into a neighborhood main street. While primarily residential in form, this type may be used for live-work and similar medium intensity retail, service, and office uses.

Townhouse

(2) Lot.

Lot area No minimum.

Lot width 50-foot minimum, 200-foot maximum; dwelling width: 16-foot minimum.

Build-to line locations Corner lots 0—10 feet from front property line.

0—10 feet from side street property line.

Interior lots 0—15 feet from front property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 75—100 percent of lot frontage.

Building coverage 85 percent maximum.

Dwelling area 600-square foot minimum.

(3) Height.

Building Height Main building: 2 stories minimum, 3 stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First Floor Elevation First Floor Residential: 3 feet above grade minimum (4 feet encouraged).

First Floor Nonresidential: 0-inches—6-inches above grade maximum.

(4) Required frontage. Buildings are required to have either a front porch or stoop.

(5) Use. Where the underlying zoning is R-2, this building type/lot may only house multifamily dwellings and live-work townhouses as defined in section 22-626. Otherwise, this building type/lot may house all permitted uses in the VPO as defined in section 22-626; except: dwelling, single-family and two-family, corner store, and uses specific to landmark buildings.

Note: Mixed-use with upper-story residential is encouraged. Personal care homes shall be limited to two residents per individual unit (dwelling).

(g) Corner store.

(1) Building type. This building type is a small to medium-sized retail structure that sits on a corner facing lot at a prominent intersection or neighborhood center. The building contains a ground floor shopfront located along the sidewalk at the street level. It is typically located within a residential neighborhood in a walkable urban setting. If more than one story, this building type may be mixed-use with either a residence or office space on the upper floor.

Corner Store

(2) Lot.

Lot area No minimum.

Lot width 35 -foot minimum, 70-foot maximum.

Build-to line locations Corner lots:

0 feet from front property line.

0 feet from side street property line.

Side setback Primary structure: 5-foot minimum.

Accessory structure: 0-foot minimum.

Rear setback None.

Building frontage 70—100 percent of lot frontage.

Building coverage 80 percent maximum.

Dwelling area 600-square foot minimum.

(3) Height.

Building Height Main building: 2 stories minimum, 3 stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor: 10 foot minimum, 14 foot maximum.

Upper story: 8 foot minimum, 12 foot maximum.

First floor elevation Commercial form: 0 inches—6 inches above grade maximum.

Residential form: 2 feet—3 feet above grade minimum.

The corner store shall be commercial in form, except where approved by the zoning administrator.

5 feet above grade maximum.

(4) Required frontage. Building fronts are required to have at least one of the following: gallery, colonnade, arcade, terrace, second floor balcony, marquee, awning, or porch (residential character only).

(5) Use.

a. First floor. This building type/lot shall house a nonresident corner store use on the first floor as defined in section 22-626.

b. First floor rear, side, and upper stories. In those areas not occupied by the first floor storefront, including upper stories, this building type may house all permitted uses in the VPO as defined in section 22-626, except: live-work townhouse and personal care home (group). In an effort to create mixed-use residential buildings, single-family, two-family, and multifamily dwellings shall be encouraged on upper floors.

(h) Shopfront building.

(1) Building type. This building type is a small to medium-sized detached structure of one to two stories with a storefront treatment that most often accommodates commercial uses. The front facade is typically flat, often with a canopy or awning frontage. The entry may be recessed. This type is a primary component of a mixed-use main street.

Shopfront Building

(2) Lot.

Lot area No minimum.

Lot width 35-foot minimum, 100-foot maximum.

Build-to line locations Corner lots:

0 feet from front property line.

0 feet from side street property line.

Side setback None.

Rear setback None.

Building frontage 70—100 percent of lot frontage.

Building coverage 80 percent maximum.

(3) Height.

Building Height Main building: 1 story minimum, 3 stories maximum.

Story Height Ground floor: 10-foot minimum, 20-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 0 inches—6 inches above grade maximum.

(4) Glazing/transparency. In order to provide clear views of merchandise in stores and to provide natural surveillance of exterior street spaces, the ground-floor along the building frontage shall have untinted transparent shopfront windows and/or doors covering no less than 75 percent of the wall area of principal facade. Corner lots: no less than 50 percent of the wall area of the secondary facade.

(5) Required frontage. Building fronts are required to have at least one of the following: front porch, gallery, colonnade, arcade, terrace, second floor balcony, marquee, or awning.

(6) Use.

a. First floor. This building type/lot shall house a nonresidential use on the first floor as defined in section 22-626; except: corner store.

b. First floor rear and upper stories. In those areas not occupied by a nonresidential use, including upper stories, this building type may house all permitted uses in the VPO as defined in section 22-626. In an effort to create mixed-use residential buildings, singlefamily, two-family, and multifamily dwellings shall be encouraged on upper floors.

(i) Flex building.

(1) Building type. This building type is a small to large-sized detached structure of one to two stories with a storefront or workshop treatment that most often accommodates commercial, recreational entertainment, and light industrial uses that are too large or too intense to be appropriately housed in a shopfront building type. This building is inspired by the local vernacular, including the city's railroad sheds, warehouses, and retail and service establishments on E. Clay Street and W. Jackson Street. The front facade is typically flat, often with a canopy or awning frontage. This type is a primary component of a flexible urban neighborhood that provides a mix of buildings.

Flex Building

(2) Lot.

Lot area No minimum.

Lot width 35-foot minimum, 250-foot maximum.

Build-to line locations Corner lots:

0—20 feet from front property line.

0—20 feet from side street property line.

Side setback 0—10 feet from side property line.

Rear setback None.

Building frontage 80—100 percent of lot frontage.

Building coverage 80 percent maximum.

(3) Height.

Building Height Main building: 1 story minimum, 3 stories maximum.

Accessory dwelling unit: 2 stories maximum.

Story Height Ground floor: 10-foot minimum, 20-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 0 inches—6 inches above grade maximum.

(4) Required frontage. Building fronts are required to have at least one of the following: front porch, gallery, colonnade, arcade, second floor balcony, marquee, or awning.

(5) Use.

a. First floor. This building type/lot shall only house a nonresidential use on the first floor as defined in section 22-626; except: corner store.

b. First floor rear and upper stories. In those areas not occupied by a nonresidential use, including upper stories, this building type may house all permitted uses in the VPO as defined in section 22-626. In an effort to create mixed-use residential buildings, singlefamily, two-family, and multifamily dwellings shall be encouraged on upper floors.

(j) Landmark building.

(1) Generally. Landmark buildings are designed for occupancy by public or commercial uses that provide important services to the community, including recreation, education, safety, assembly, and related functions. They contribute significantly to the quality of the neighborhood and often serve as the focal point of a civic space, terminate a vista, or are placed at a prominent location. The architectural quality and construction of a landmark building shall be of the highest level and exceed that of nearby buildings.

Landmark Building (2 as 1)

(2) Review process. Design and disposition (dimensional requirements): All landmark buildings shall be negotiated on a case-by case basis with the supervising planner prior to application.

(3) Building location. The following criteria should be considered when determining the location of a landmark building within the community, on the block, and on the lot:

a. Primary function;

b. Perceived level of importance to the community;

c. Desired level of formality; and

d. Sense of permanence.

(4) Location within the community and block. Buildings shall be sited at prominent locations and oriented toward a public street or public space in a manner that:

a. Provides a corner or midblock terminating vista;

b. Anchors a civic space; or

c. Fronts a street and civic space.

(5) Location on the lot (setback). Landmark buildings often benefit from being set back from the adjacent build-to lines of private development, thereby:

a. Allowing the scale of the building to have more visual emphasis; and

b. Creating a public space in the foreground.

The amount of this setback should be carefully determined based on programming and the urban design objectives of the particular site.

(6) Multiple buildings/campus. Facilities with multiple buildings or a campus-like setting shall comply with the standards of subsection (k) of this section.

(7) Building type and character. The following facilities may be designed to an existing building type:

a. Private and quasi-public clubs or lodges;

b. Small-scaled cultural facilities such as museums;

c. Public recreation centers and similar facilities that are minor or secondary in nature; and

d. Small- to medium-scaled bus passenger stations in which passenger boarding occurs outside the building.

(8) Inspirational structures. Structures that draw inspiration from an existing building type may be integrated into the urban fabric or streetscape with little to no additional emphasis. All other landmark buildings shall be designed as freestanding, "monumental" structures that evoke pride in one's community and convey a sense of timelessness.

(9) Vehicle access and parking. To the maximum extent practicable:

a. Parking shall not be located between a principal or secondary facade and a primary or secondary street;

b. Parking requirements for the site shall be met with on-street parallel and angled parking spaces, or via a remote parking lot or structure;

c. Parking shall be accessed from a side street or alley;

d. Parking drives and access shall be shared with adjacent lots; and

e. Drop-off, pick-up, and stacking for the site shall occur on or along a public street (may be privately-owned).

If the building is sited in a public space, vehicular access shall be limited to service and emergency vehicles utilizing pedestrian walkways of sufficient width and construction.

(10) Building design; facades and entrances. A facade that fronts a primary street shall be considered to be the building's principal facade, and a facade that fronts a secondary street shall be considered to be the buildings secondary facade.

a. The principal facade shall be designed to be the most prominent facade of the building.

b. Building entrances shall always take access from the most prominent facades.

Additional entrances may be provided along secondary and axillary facades.

(11) Required frontages. Building fronts shall have at least one of the following: porch, stoop, gallery, colonnade, arcade, terrace, balcony, marquee, canopy, or awning.

(12) Massing.

a. Symmetrical in form.

b. The appearance of a balanced design increases the level of formality, and shall be encouraged.

c. Massing, while often larger as a whole, should be divided into visually distinct sections.

d. Massing divisions should provide visual order to the building and create vertical proportions within individual elements.

e. On corner lots, landmark buildings shall be designed with two facades of equal, though not identical architectural quality.

f. Landmark buildings located in a civic space shall be designed with four facades of equal, though not identical architectural quality.

(13) Scale.

a. Size. In order to be more visually prominent across greater distances, the scale of the building should be larger than that of nearby buildings.

b. Building height. Three stories maximum, 48 feet above grade maximum (excluding appurtenances).

c. Story height. Floor-to-ceiling heights and architectural details should be proportionately larger than those of nearby private buildings.

d. Roof appurtenances. Spires, steeples, towers, cupolas, and belfries can visually extend the height of the building, and shall be incorporated when practicable.

e. Materials. Buildings shall use durable, high quality materials that convey a sense of permanence. These include, but are not limited to, brick, stone, and cast concrete. Wood construction is appropriate, but should only be executed with the highest quality framing and cladding materials. Generally, stucco should be avoided as a material that lacks scale and texture. If used, stucco should be traditional, have integral pigment, and be scored to define human-scaled dimensions on the facade.

(14) Specific to churches and places of worship. In addition to the above standards, churches and places of worship shall:

a. Traditional design. A church should be easily identifiable with timeless features such as bell towers, steeples, clearstory windows, and stained glass integrated into the design. Traditionally designed buildings can be navigated easily based on intuition without much signage. For example, if a sign or large symbol (e.g., cross) is needed to identify the sanctuary then the design can be improved.

b. Vertical massing. The scale of the sanctuary building should not overwhelm the block.

Building features such as arches, columns, pilasters, rooflines (including dormers), and masonry patterns shall divide and create a vertical orientation on larger surfaces. Once these proportions have been established, windows (including clearstory) and doors shall reinforce the vertical orientation of the composition.

c. Be transparent. Being able to see and hear a little bit of what's going on inside makes a church seem less intimidating and peeks the interest of those passing by. This is the same principal as window-shopping, only adapted to a church. It is not uncommon for people to join a service after hearing music wafting through the doors of a church.

d. Define entrances. The church's buildings should be open and inviting, with a clear sense of where to enter. In no case shall a church's side doors function as a primary entry point.

e. Entrances close to pedestrians. Use frontage elements such as porches, stoops, galleries, arcades, and canopies to bring the church up to the street or public space, while still providing an area for people to gather.

f. Doors. Church doors should be prominent and inviting.

g. Parking. Parking lots disrupt the neighborhood fabric and discourage members from walking to and from church, resulting in less patronage of local shops and cafes. Parking should be on-street or shared with other commercial or institutional buildings in the vicinity.

h. Create a community focal point. Add neighborhood-friendly features such as athletic fields, tennis or basketball courts, a playground, an outdoor amphitheater, etc.

i. Permeable campus. Churches that span more than one block shall ensure that their campus is permeable, allowing people to walk through the property using multiple routes.

(15) Use. This building type/lot may only house churches or other place of worship; public owned recreation centers, YMCAs and institutions of a similar nature; schools (public or private);

business schools; clubs or lodges (private); colleges or universities; cultural facilities; railroad or bus passenger stations; and municipal structures as defined in section 22-626.

(k) Cottage court.

(1) Building type.. The cottage court consists of a series of small, detached structures on a single lot, providing multiple interior units arranged to define a shared court that is typically open to, and perpendicular to the street. The shared court takes the place of a private rear and becomes an important community-enhancing space.

Cottage Court

(2) Lot.

Setback Diagram Lot Proportions Depth: 75-foot minimum, 150-foot maximum.

Width: 75-foot minimum, 150-foot maximum.

Lot Setbacks

A. Front/street: 0—10 feet.

B. Side: 5-foot minimum.

C. Rear: None.

Building Setbacks

D. Common court: None.

E. Side yard spacing between primary buildings:

10-foot minimum.

Building coverage 75 percent maximum.

Dwelling area No minimum.

(3) Height.

Building height 21 /2 stories maximum.

Story height Ground floor Residential: 14-foot maximum.

Nonresidential: 10-foot minimum, 14-foot maximum.

Upper story: 8-foot minimum, 12-foot maximum.

First floor elevation 2-foot minimum; 5-foot maximum above grade.

Nonresidential shopfront-like uses may request a minimum of 0 inches—6 inches from the zoning administrator.

(4) Buildings.

Buildings per lot 3 minimum; 9 maximum.* Units per lot (multiple rooms may comprise unit) 3 minimum; 9 maximum; Attached units permitted.* When used for B&B* Buildings per lot: 3 minimum; 9 maximum.

Units per lot: 3 minimum; 18 maximum.

(5) Courtyard.

Area F. 400 square foot minimum.

Proportions F. Depth: 20-foot minimum.

F. Width: 20-foot minimum.

(6) Allowed frontages. Buildings are required to have a front porch (may be substituted with a stoop if approved by city planner).

(7) Use. While typically residential in form, the cottage court allows for the establishment of a single-lot cluster of buildings dedicated to a variety of functions including one- and two-family, and multifamily residential, lodging*, retail, arts, and similar uses. The cottage court functions much like a mansion apartment or shopfront building, only the units have been de-centralized and sited around a common space. Accessory dwelling units (ADUs) are prohibited.

*If used for a B&B, a "unit" equals a "rentable unit," and the maximum permitted number of rentable units is 18.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Code 1991, § 22-502; Ord. of 3-10-2014, § 3; Ord. No. 11192014-1, § 3, 11-19-2014; Ord. No. 04112016-2, 4-11-2016; Ord. No. 12112017-1, § I, 12-11-2017; Ord. No. 12112017-1, §§ V—VIII, 12-11-2017)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:thomasville/zoning/22-620@2026-10-20-d6571ce7e9

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Thomasville Zoning Ordinance, Sec. 22-620. Building types | Georgia Commons