(a) Frontages and building elements.

(1) Porches. Porches provide outdoor living space. Often, they provide protection from the sun, while still permitting breezes to infiltrate the body of the building. They provide architectural interest and delineate the building's entrance. This type is appropriate for residential building types with small setbacks. Typically, the porch is located in the build-to-zone as close to the sidewalk as possible. It is elevated to ensure privacy within the building from those passing by.

Stairs may lead directly to the sidewalk or may be side-loaded.

a. Depth: seven-foot minimum (measured from face of building to outside of column face).

b. Length: 25—100 percent of building front; ten-foot minimum.

c. Porches shall be covered by a columned or bracketed roof or set into the main body of the building.

d. Height, clear = eight-foot minimum.

e. Height: two stories max; porches may have multi-story balconies above.

f. Finish level above grade: 12-inch minimum; five-foot maximum (no more than eight inches below the first interior finished floor level).

g. Porches may occur forward of the build-to line, but shall not extend into the right-of-way.

Stairs may encroach within the right-of-way with easement permission, so long as full sidewalk clearance is maintained.

h. Porches and stoops shall match the architectural language of the building, with similar details and materials. Screens on front porches are prohibited.

(2) Galleries, colonnades, arcades, and terraces. This frontage is associated with commercial uses, and is permitted to encroach upon the setback, or even into the right-of-way over the sidewalk.

The space allows one to window-shop or dine in a shaded environment that also captures breezes. The frontage provides architectural interest and delineates the building's entrance.

Upper stories may be enclosed, providing livable bonus space for occupants.

a. Depth: ten-foot minimum (measured from face of building to outside of column face)

b. Length: 75—100 percent of building front; may wrap side of building on corners.

c. Height, clear = nine-foot minimum.

d. Height: four stories max; may have enclosed habitable space on upper stories.

e. Finish level above grade: zero- to six-inch max; terraces, whose finish level above grade shall be no more five feet and no more than eight inches below the interior finished floor level.

f. Galleries, colonnades, and arcades are supported by columns, piers, or arches and may encroach within the right-of-way with easement permission, occurring forward of the build-to line to within two feet of the curb.

(3) Balconies. A balcony is connected to a building's upper stories and is supported by either a cantilever or by columns on one side. This type is appropriate for residential and commercial buildings with small setbacks. Typically, the balcony is located forward of the build-to-zone over the sidewalk. It allows occupants of the building to experience the activities of the street while also providing significant privacy from those passing by.

a. Depth: three to six feet measured perpendicular to wall face (five-foot minimum second story).

b. Length: 25—100 percent of building front; five-foot minimum.

c. Height, clear = nine-foot minimum.

d. Balconies may encroach within the right-of-way with easement permission, occurring forward of the build-to line to within two feet of the curb.

e. Balconies shall be made of wood or metal and may have roofs, but are required to be open, un-airconditioned spaces. Balconies in the rear of the building may have screens. Balconies shall match the architectural language of the building.

f. Balconies should be supported from below by visible brackets, scaled as if they are supporting the weight of the mass, or from above by suspension cables or chains.

Contemporary, cantilevered balconies may be exempt from this requirement.

g. On corners, balconies may wrap around the side of the building facing the side street.

(4) Canopies and awnings. A permanently roofed architectural projection whose sides are either vertical or horizontal and are supported entirely from an exterior wall of a building. This frontage is typically used for the display of signs. Horizontal marquees, canopies, and awnings provide shade from the sun, as well as enhanced weather protection for both the building and the passerby.

a. Depth: five-foot minimum measured perpendicular to wall face.

b. Length: 25—100 percent of building front; may wrap side of building on corners.

c. Height, clear = nine-foot minimum.

d. Canopies and awnings may encroach within the right-of-way with easement permission, occurring forward of the build-to line to within two feet of the curb.

e. Canopies and awnings shall be continuous above openings below. Breaks in awnings shall coincide with breaks in shopfront openings below.

f. Canopies shall be visually supported from below by brackets, or from above by suspension cables or chains spaced at regular intervals.

g. The top of each awning shall be at the same height as the top of each opening below.

h. Awnings shall be made of fabric. Vinyl and high-gloss or plasticized fabrics are prohibited.

i. Backlit awnings are prohibited.

j. Sign copy on canopies and awnings on upper story windows is not permitted.

k. The above standards are applicable to first floor awnings and canopies only.

(b) Scale, massing and roofs.

(1) Description. Commercial, multi-family, and residential buildings should reflect a combination of vernacular and more formal architecture. Essential characteristics include:

a. Raised foundations for residential buildings.

b. At-grade foundations for commercial buildings, low rise hotels, landmark buildings, and mixed use commercial buildings with upper story office or residential.

c. A clearly discernible base (e.g. foundation/water table), middle, and top (e.g. roof) on each building.

d. The use of permanent and durable materials.

e. Buildings are typically simple combinations of one or more rectangular forms.

f. Simple, one to four story massing, with a mix of gabled, hipped, and parapeted roofs.

g. Both enclosed eaves with simplified classical detailing and exposed rafter ends.

h. Porches with simplified classical detailing. Mixed architectural vocabulary, utilizing wood, stucco, and masonry.

1. Multi-family buildings. Multi-family buildings find precedent in the mansion apartment houses of downtown Thomasville and rowhouses of other larger southern cities. The former are configured to resemble a large single-family house. Both types should convey the character and level of architectural refinement found in traditional neighborhoods.

2. Commercial buildings. These buildings are typically commercial in character, appearing as attached or stand-alone, single or mixed use structures with parapeted or gabled, pedimented roof forms, and formal shopfronts.

3. Landmark buildings. These buildings are sited and designed to celebrate the community, its image, values, and priorities. The architectural quality and construction of the building should be of the highest level, and exceed that of nearby buildings.

(2) Massing.

a. Buildings shall incorporate variations in wall heights, façade articulations, and varied roof planes and pitches.

b. Wall planes shall be divided into visually distinct sections that provide visual order and create vertical proportions by the arrangement of windows and features such as columns, pilasters, canopies, and clearly-articulated entrances.

c. The main entrance to a building shall be clearly identifiable and shall be oriented to face a public street or space with direct sidewalk access. Entrances shall incorporate design features such as canopies, porticos, arcades, raised cornice parapets or peaked roof forms over the doorways, arches, and display windows.

d. Buildings in the development shall be articulated and finished on all sides. Sides of commercial or mixed-use buildings that do not face (or will not likely face) a residential building or public street or space are exempt.

(3) Roofs.

a. Roofs are typically gabled, or hipped, with some flat.

b. Half stories are typically articulated utilizing gable ends and dormers.

c. Commercial and multi-family buildings shall have relatively steep slopes, ranging from 8 in 12 to 10 in 12. Larger commercial buildings may have slopes from 4 in 12 to 8 in 12 or have flat roofs.

d. Porch roofs may have a lower pitch with a minimum slope of 3 in 12.

e. Parapets are required around the perimeter of all flat roofs and shall extend up to a minimum of two feet above the top of the adjacent roof.

f. Roof penetrations and equipment (except chimneys) shall be screened by parapet, located on the rear slope, or otherwise configured to have as minimal visual impact as practicable from the public street or space.

g. Shed (monopitch) roofs shall only be attached to the principal building walls, with a minimum slope of 2 in 12.

h. Applied Mansard roofs shall not be permitted.

1. Architectural (cupolas, towers, steeples, chimneys, etc.) and mechanical (heat and air, elevator enclosure, etc.) appurtenances may exceed the allowable building height as follows:

(i) Appurtenances may extend up to one story above the height limit. Roof area (combined) = 25 percent maximum.

(ii) Towers are permitted on landmark buildings, low rise buildings, and any corner building. The dimensional footprint shall not exceed 30 by 30 feet.

(iii) Cupolas are permitted on all building types except townhouse. The maximum height shall be fix feet (measured from ridge of roof upon which it sits, excluding pinnacles). The maximum width shall be four feet including the roof and base. Cupolas shall be either square, round, or octagonal in plan, and their overall proportion shall be vertical.

(4) Roof-wall connections.

a. Eaves may utilize exposed rafter tails with minimal fascia depth or an enclosed cornice and entablature with simplified classical detailing. Box eaves (porkchops) shall be prohibited.

b. Roof overhangs shall have a minimum eight-inch overhang at eave and rake.

(5) Primary walls.

a. Primary walls may be clad in wood, cement fiber siding, brick, concrete masonry units with stucco (C.B.S.), reinforced concrete with stucco, shingle, and/or vertical board and batten.

b. Siding may be mitered at building corners or clad with a minimum four-inch trim board.

Trim board is typically six-inch.

c. Exposed wood shall be unpainted, painted, or stained.

d. Brick mortar joints shall be struck.

e. Stucco shall be smooth and sand finish only.

f. Two or more wall materials may be combined on one façade only with the lighter material above the more substantial material (e.g. wood above stucco or masonry, or stucco above masonry).

g. Decorative moldings, cornices, or an applied ornament of stone or cast concrete may be used to express the vertical division between the base, body, and the top.

h. Cantilevers shall be supported by visible brackets scaled as if they're supporting the weight of the mass above.

(6) Base.

a. Exposed foundation walls (below first floor) shall be: brick, painted brick, or stucco over block or concrete.

b. Primary walls, when set on a raised crawlspace foundation, should rest on a drip edge and water table or sill and fascia (wood or cementitious) over foundation piers.

c. Foundation piers shall be no less than 12 inches square. If the foundation is taller than four feet above grade, than the foundation piers shall be no less than 16 inches square.

d. Crawlspace openings and the undercroft of foundations, decks, and porches shall be framed in lattice, vertical pickets, and/or hogs pen pattern (wood or similar).

(7) Openings.

a. Façade composition. Simple and regular rhythm of openings, often divided into equal bays of three, five, or seven.

b. Windows and doors.

1. Windows may be double or single hung, or casement; with first story windows taller than upper story windows.

2. When utilized with wood cladding materials, windows and doors shall be framed with a minimum three and one-half inches wood or fiber cement trim or similar composite trim. When utilized with stucco or masonry cladding materials, windows and doors shall be framed with a minimum two and one-half inches brick mold.

3. Windows may not be flush with the wall plane but shall be recessed.

4. Windows shall be located no closer to the corner of a building than a dimension equal to the width of the window.

5. All windows shall have a sill. The sill should not be integrated into a "picture frame" surround.

6. Windows shall be vertically- or square-proportioned and multi-paned with exterior true or simulated muntins. Horizontally proportioned clerestory and transom windows are permitted if part of an overall vertical composition.

7. Window panes may be in a one-over-one, two-over-two, six-over-six, or six-overnine divided light pattern.

8. When windows are ganged together, a three-inch minimum mullion shall be between each individual window.

9. All glass shall be clear and non-reflective. If glass incorporates tinting, it should be transparent enough for those outside the building to see building occupants.

10. Shutters, when used, shall be sized equal to one-half the width and the same height as the window; and be operable.

11. Panels and windows on doors should be simple and rectilinear. Transom and side panel windows are allowed.

12. On upper floors, a minimum of 25 percent of glazed.

c. Shopfronts.

1. All regulations regarding windows and doors described above shall apply to a shopfront assembly.

2. The top of shopfront window sills shall be one to three feet above the adjacent sidewalk.

3. Shopfront windows shall extend uninterrupted at least eight feet above the adjacent sidewalk.

4. Shopfronts shall have a cornice or expression line above, between the first and second floor.

5. Shopfront assemblies shall be made of painted or varnished wood, aluminum-clad wood, or painted metal.

6. In multi-story buildings, there shall be a horizontal band, articulated fascia, and/or entablature to separate the ground level shopfront from the upper floors. This band may be incorporated into the shopfront design.

7. Frontage treatments (e.g. porches, galleries, awnings, etc.) may be incorporated into shopfront designs.

8. Shopfront edges should integrate heavier piers or pilasters to visually carry the weight of the building above.

9. Lighting shall be mounted on the store front wall, preferably centered on the piers between windows/doors or centered above the windows/doors of the shopfront.

Where projected shed roofs are used over entries the lighting may be mounted in the shed underside.

(c) Architectural elements.

(1) Columns.

a. Columns shall be arranged such that they appear to support the weight of the structure above, for example a beam or arch. The outside edge of the structure (beam or arch) shall align with the neck of the column, not the edge of the capital.

b. Openings created between columns shall always be vertically proportioned.

(2) Porches.

a. Bay spacing on porches shall remain vertically proportioned or square.

b. Columns should utilize architecturally correct capitals and bases. Columns shall be: width = six-inch minimum; shape = round or square (may be fluted, paneled, or tapered).

c. Porches shall be made predominantly of wood.

d. Railing spindles and pickets on porches shall not exceed four inches on center, or as required by the building code, whichever is less. Standard pipe rails are prohibited.

(3) Galleries, colonnades.

a. Bay spacing on galleries shall be vertically proportioned or square.

b. Columns should utilize architecturally correct capitals and bases. Columns shall be: width = six-inch minimum; shape = square or round.

(4) Balconies. Spindles and balusters on balconies shall not exceed four inches on center, or as required by the building code.

(5) Brick and masonry detailing.

a. Header. The horizontal member spanning the top of an opening.

1. All openings in brick construction shall be spanned by a header.

2. Acceptable header forms are the lintel, arch and jack arch.

3. Headers may be comprised of a variety of materials including; brick, stone, cast stone, and metal.

4. The header should visually appear able to carry the wall load above.

5. Headers shall be a minimum of four inches in height and slightly wider than the opening they span.

b. Sill. The horizontal member at the base of a window opening.

1. All window openings in brick construction shall have a sill at their base.

2. Sills are generally rectangular in form, and sloped slightly away from the window opening to shed water.

3. Sills may be comprised of a variety of materials including: brick, stone, cast slone, and terra-cotta.

4. Sills should be a minimum of two inches in height and should project from the wall surface a minimum of one inch.

5. Sills should be slightly wider than the window opening.

c. Cornice. A horizontal molded projection that crowns or completes a brick building wall.

1. A cornice shall be composed of brick, stone, cast stone or wood.

2. A cornice may be a simple corbel to provide a shadow line, or may be more ornate in construction.

(6) Accessibility. ADA ramps may be incorporated into the architecture of the building, ideally along the side or rear façade. Such ramps may occur forward of the build-to line, but shall not extend into the right-of-way. They may encroach upon the side setback by five feet maximum.

(d) Permitted materials.

(1) Cladding.

a. Siding in:

1. Wood (termite resistant, 50-year siding product).

2. Composition board.

3. Cement fiber siding (50-year siding product).

4. Vertical board and batten (using materials above).

b. Concrete masonry units with stucco (C.B.S.).

c. Reinforced concrete with stucco.

d. Brick, with struck mortar joints.

e. Scored stucco imitation brick is prohibited.

f. EIFS, Styrofoam, and other foam-based products are prohibited on building exteriors.

g. Vinyl and/or T-111 siding are not allowed.

(2) Foundations. Brick, concrete, or stucco.

(3) Roofing.

a. Narrow standing seam metal.

b. Galvanized or painted metal roof panels.

c. Rolled asphalt with ice and water shield.

d. Fiberglass, wood, or slate shingles.

(4) Windows. Wood, clad wood, metal, steel, vinyl.

(5) Doors.

a. Wood or clad wood.

b. Metal or steel.

c. Fiberglass.

(6) Trim.

a. Wood (termite resistant, 50-year product).

b. Composition board.

c. Fiber-cement board.

d. Molded millwork for built-up sections.

e. For soffits and porch ceilings:: Gypsum Wall Board (GWB), Plaster, Tongue and Groove (T&G) wood. Exposed rafters, or composite. Vinyl panel systems are not permitted on porch ceilings. If soffit is perforated, the pattern should be fragmented or as ambiguous as possible.

(7) Gutters.

a. Half round or ogee-profile metal.

b. PVC is not permitted.

(8) Downspouts.

a. Round or rectangular metal.

b. PVC is not permitted.

(9) Columns. Wood, fiberglass, composite, cast iron, concrete with smooth finish, brick, or stone.

(10) Railings.

a. Square balusters.

b. Turned spindles and ornamental shapes in wood or wrought iron.

(11) Chimneys.

a. Common brick.

b. Stucco.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. No. 38-11102025, § II(Exh. A), 11-10-2025)