Troup County · Ordenanza de zonificación
Appendix B - LAND USE AND ZONING / Article V - CIVIC DESIGN
Sec. 5.2. Building typology.
Sobre este texto
- As published by Municode, current through 2026-06-16
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(1) This section provides standards for a variety of building types. Building types provide many key dimensional standards for each zoning district.
Not all accessory building types are listed in this section, but may be approved if in compliance with the use and dimensional requirements provided elsewhere in the UDO.
(2) Building types are applied to help reinforce the existing character and scale of the County.
Note that these building types are for zoning purposes only and are not linked to the Building Code.
(3) The following building types are permitted in the zoning districts delineated in the following chart. Allowable building types are
indicated with a "P."
(4) Building types are prohibited in zoning districts that are not indicated with a "P."
(5) The illustrative drawings provided in this Chapter do not represent required architectural elements, styles, or regulations and are intended to be informational only. Each building typology includes an illustration and additional building design regulations provided in charts for each building type. Notations provided on the corresponding illustrations in the form of letter designations such as "A" through "D" are further
defined in each building typology chart.
Building Typology Table Building Type by Zoning District AG AG-R LR SU-R SU-VL UR-VL LC HC LI HI SD-MH Manufactured home P P Garage apartment P P P P P P Backyard cottage P P P P P P Cottage house P P P P P P Detached house P P P P P P Cottage court P Two-family dwelling P Attached house P Building Type by Zoning District AG AG-R LR SU-R SU-VL UR-VL LC HC LI HI SD-MH Townhouse P Walk-up flat P Stacked flat P Single-story shopfront P P P P P Mixed-use shopfront P P P General building P P P P P P P P P P Civic building P P P P P P P P P P Garage Apartment A building type designed to accommodate a small self-contained accessory dwelling unit located above a garage on the same lot as a principal structure.
Uses allowed in this building type: Accessory Dwellings.
See section 5.4 for additional architectural regulations.
See article 7, Supplemental Use for supplementary regulations for accessory dwellings.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, side yard, street side yard, rear yard, and front yard requirements.
B Maximum height: 35 feet.
C Maximum floor area: 1,200 square feet.
Backyard Cottage A building type designed to accommodate a small self-contained accessory dwelling unit located on the same lot as a principal structure.
Uses allowed in this building type: Accessory Dwellings.
See section 5.4 for additional architectural regulations.
See article 7, Supplemental Use for supplementary regulations for accessory dwellings.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, side yard, road/street side yard, rear yard, and front yard requirements.
B Maximum height: 35 feet.
C Maximum floor area: 1,500 square feet.
Cottage House A building type designed to accommodate one (1) small dwelling unit on an individual lot or with additional units on a single lot with yards on all sides of the house.
Uses allowed in this building type: Single-Family Detached Dwellings.
See section 5.4 for additional architectural regulations.
Minimum floor area shall be 750 square feet per dwelling.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural, agritourism, and Rural Tourism uses.
B Roof pitch for the primary roof structure shall be a minimum of 5:12. Roof materials shall be asphalt, fiberglass shingle, cedar, slate, or standing seam metal.
Buildings shall utilize at least two (2) of the following design features to provide visual relief along the front of the dwelling unit: Dormers
(functional or false); Gables; Recessed entries;
Covered front porches; Pillars or posts; Arches;
Quoin corners; Two (2) or more brick masonry bond treatments; Side loaded garage or carport;
and Bay windows (minimum 24-inch projection).
The minimum roof overhang shall be 12 inches, exclusive of porches and patios.
Detached House A building type designed to accommodate one (1) primary dwelling unit on an individual lot with yards on all sides.
Uses allowed in this building type: Single-Family Detached Dwellings.
See section 5.4 for additional architectural regulations.
Minimum floor area shall be 1,000 square feet per dwelling.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural, agritourism, and Rural Tourism uses.
B Roof pitch for the primary roof structure shall be a minimum of 5:12. Roof materials shall be asphalt, fiberglass shingle, cedar, slate, or standing seam metal.
D Buildings shall utilize at least two (2) of the following design features to provide visual relief along the front of the dwelling unit: Dormers (functional or false); Gables; Recessed entries;
Covered front porches; Pillars or posts; Arches; Quoin corners;
Two (2) or more brick masonry bond treatments; Side loaded garage or carport; and Bay windows (minimum 24-inch projection).
The minimum roof overhang shall be 12 inches, exclusive of porches and patios.
Cottage Court A building type designed to accommodate 5 to 9 detached dwelling units organized around a shared internal courtyard. Units cannot be vertically mixed.
Uses allowed in this building type: Single-Family Detached Dwellings.
See section 5.4 for additional architectural regulations.
Individual Cottage Houses shall meet the requirements for the Cottage House building type.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural, agritourism, and Rural Tourism uses.
B Cottage court development shall be designed to orient the units around a shared internal courtyard. Each unit shall have a direct entrance from the courtyard.
C The courtyards shall be a minimum of 2,000 square feet in size.
A minimum of 70 percent of the courtyard shall consist of pervious material, of which a minimum of 50 percent of the courtyard shall be landscaped. Courtyards shall not be parked or driven
upon except for emergency access and permitted temporary events.
D A cottage development may be subdivided into individual lots that do not meet the minimum road/street frontage requirements and may be treated as fee-simple or condominium lots.
Two-Family Dwelling A building type designed to accommodate two (2) dwelling units that share a common wall or floor/ ceiling on a single individual lot.
Uses allowed in this building type: Two-Family Dwellings.
See section 5.4 for additional architectural regulations.
Minimum floor area shall be 750 square feet per dwelling.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements. Side yard
requirements do not apply to the common walls permitted as part of this building type.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
B Roof pitch for the primary roof structure shall be a minimum of 5:12. Roof materials shall be asphalt, fiberglass shingle, cedar, slate, or standing seam metal.
D Buildings shall utilize at least two (2) of the following design features to provide visual relief along the front of the dwelling unit: Dormers (functional or false); Gables; Recessed entries;
Covered front porches; Pillars or posts; Arches; Quoin corners;
Two (2) or more brick masonry bond treatments; Side loaded garage or carport; and Bay windows (minimum 24-inch projection).
The minimum roof overhang shall be 12 inches, exclusive of porches and patios.
Attached House A building type that accommodates two (2) dwelling units that share a common wall along the lot line between two (2) lots.
Uses allowed in this building type: Single-Family Attached Dwellings.
See section 5.4 for additional architectural regulations.
Minimum floor area shall be 1000 square feet per dwelling.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements. Side yard
requirements do not apply to the common walls permitted as part of this building type.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
Roof pitch for the primary roof structure shall be a minimum of 5:12. Roof materials shall be asphalt, fiberglass shingle, cedar, slate, or standing seam metal.
D Buildings shall utilize at least two (2) of the following design features to provide visual relief along the front of the dwelling unit: Dormers (functional or false); Gables; Recessed entries;
Covered front porches; Pillars or posts; Arches; Quoin corners;
Two (2) or more brick masonry bond treatments; Side loaded garage or carport; and Bay windows (minimum 24-inch projection).
The minimum roof overhang shall be 12 inches, exclusive of porches and patios.
Townhouse A building type designed to accommodate 3 to 6 dwelling units where each unit is separated by a common side wall. Units cannot be vertically mixed.
Uses allowed in this building type: Townhouse Dwellings.
See section 5.4 for additional architectural regulations.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements. Side yard
requirements do not apply to the common walls permitted as part of this building type.
The following regulations apply to all uses excluding Agricultural and Agritourism and Rural Tourism uses.
Each townhouse shall have a minimum of 200 square feet of private yard space in either the front or rear, not including driveways and alleys.
All townhouse buildings shall include a continuous sidewalk 5 feet in width connecting front entrances of all dwellings to each other.
No individual townhouse shall have vehicular access to an existing external road or street. Alleys are permitted as the principal means of vehicular access for these units.
ADD roof pitch angle for when roof pitches are provided Walk-up Flat A building type designed to accommodate 3 to 6 dwelling units vertically and horizontally integrated.
Uses allowed in this building type: Multi-family Dwellings.
See section 5.4 for additional architectural regulations.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements. Side yard
requirements do not apply to the common walls permitted as part of this building type.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
Minimum heated and finished floor area for multi-family dwelling units shall be as follows: studio:
450 square feet; one (1) bedroom: 600 square feet; two (2) bedrooms: 800 square feet; three (3) bedrooms: 1,000 square feet per unit.
Multi-family units shall provide a minimum of 60 percent of units with a balcony or porch that may be occupied.
Stacked Flat A building type designed to accommodate 7 or more dwelling units vertically and horizontally integrated.
Uses allowed in this building type: Multi-family Dwellings.
Refer to Section 5.4 for additional architectural regulations.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements. Side yard
requirements do not apply to the common walls permitted as part of this building type.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
Minimum heated and finished floor area for multi-family dwelling units shall be as follows: studio:
450 square feet; one (1) bedroom: 600 square feet; two (2) bedrooms: 800 square feet; three (3) bedrooms: 1,000 square feet per unit.
Multi-family units shall provide a minimum of sixty (60) percent of units with a balcony or porch that may be occupied.
Single-Story Shopfront A single-story building type designed to accommodate retail or commercial activity.
Uses allowed in this building type: Commercial uses, Industrial uses, Public/Institutional uses, and Residential uses.
Refer to Section 5.3 for additional architectural regulations.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
B Delineation of building floors at the third story above sidewalk level and lower shall be executed through windows, belt courses, cornice lines, or similar architectural detailing.
All buildings shall have their primary facade and pedestrian entrance directly fronting and facing a public or private road or street.
Every building shall reduce its perceived height and bulk by dividing the building mass into smaller-scale components. Building walls exceeding 100 continuous horizontal linear feet shall utilize offsets, such as projections, recesses, and
changes in floor level, to add architectural interest and variety, and to relieve the adverse visual effect of a simple long wall.
Variation in the roofline of buildings and offsets in pitched roofs and gables shall be required.
Parapets in building masses exceeding 100 continuous linear feet shall be varied in height and projection and shall use decorative elements such as crown moldings, dentils, brick soldier courses, or similar detail.
The length of the facade without intervening fenestration, architectural detailing, or entryway shall not exceed 20 feet.
Fenestration treatment shall be provided for a minimum of sixty-five (65) percent of the length of all ground floor road or street frontages.
Fenestration shall not utilize painted glass, reflective glass, or other similarly treated or opaque windows.
Mixed Use Building A multi-story building type designed to accommodate ground floor residential, retail, office, or commercial uses with upper-story residential or office uses.
Uses allowed in this building type: Commercial uses, Industrial uses, Public/Institutional uses, and Residential uses.
Refer to Section 5.3 for additional architectural regulations.
Multi-family uses shall meet the requirements for the Stacked Flat building type.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural and Agritourism and Rural Tourism uses.
B Delineation of building floors at the third story above sidewalk level and lower shall be executed through windows, belt courses, cornice lines, or similar architectural detailing.
All buildings shall have their primary façade and pedestrian entrance directly fronting and facing a public or private road or street.
Every building shall reduce its perceived height and bulk by dividing the building mass into smaller-scale components. Building walls exceeding 100 continuous horizontal linear feet shall utilize offsets, such as projections, recesses, and
changes in floor level, to add architectural interest and variety, and to relieve the adverse visual effect of a simple long wall.
Variation in the roofline of buildings and offsets in pitched roofs and gables shall be required.
Parapets in building masses exceeding 100 continuous linear feet shall be varied in height and projection and shall use decorative elements such as crown moldings, dentils, brick soldier courses, or similar detail.
The length of the facade without intervening fenestration, architectural detailing, or entryway shall not exceed 20 feet.
Fenestration treatment shall be provided for a minimum of sixty-five (65) percent of the length of all ground floor road/street frontages.
Fenestration shall not utilize painted glass, reflective glass, or other similarly treated or opaque windows.
General Building A building type designed to accommodate agricultural, commercial, office, or industrial activity.
Not intended for retail sales or personal service uses.
Uses allowed in this building type: Agricultural uses; Agritourism and Rural Tourism uses; Commercial uses; Industrial uses; and Public/Institutional uses.
See section 5.3 for additional architectural regulations.
A See the Space Dimensions Table in section 4.1 for impervious surface, lot area, lot width, building height, side yard, road/street side yard, rear yard, and front yard requirements.
The following regulations apply to all uses, excluding Agricultural, agritourism, and Rural Tourism uses.
B Delineation of building floors at the third story above sidewalk level and lower shall be executed through windows, belt courses, cornice lines, or similar architectural detailing.
C All buildings shall have their primary facade and pedestrian entrance directly fronting and facing a public or private road or street.
Manufactured Homes and Residential Industrialized Buildings. Residential building types.
• Uses allowed in this building type:
Manufactured homes and residential industrialized buildings.
• See article 7 Supplemental Use Standards for supplementary regulations for manufactured homes.
• Dwelling width (min. in feet):
º Type 1: 24 feet º Type 2: 12 feet
• Roof pitch (min. in feet):
º Type 1: 5/12 º Type 2: 3/12
• Floor area (min. in square feet):
º Type 1: 1,000 º Type 2: 720
• Roof materials:
º Type 1: The roof shall have a surface of wood shakes, asphalt composition, wood shingles, concrete, fiberglass tiles, metal tiles, slate, built-up gravel materials, or other materials approved by the Community Development Department.
º Type 2: N/A
• External siding materials:
º Type 1: The exterior siding materials shall consist of wood, masonry, concrete lap, stucco, Masonite, metal lap, vinyl lap, or other materials of like appearance approved by the Community Development Department.
º Type 2: N/A
• Permanent foundation:
º Type 1: Permanent foundations shall meet the requirements of the standard building code.
º Type 2: For manufactured homes, a masonry curtain wall, solid except for the required ventilation and access, must be installed so that it encloses the area under the manufactured home to the ground level.
• Utility meter:
º Type 1: Mounted on structure only.
º Type 2: Mounted on a pole or structure.
• Landing area:
º Type 1: For all homes, a landing area is required and its width and length must be greater than or equal to the width of the entrance doorway and shall have a roof on the landing in the same material as on the roof of the dwelling.
º Type 2: For all homes, a landing area is required, and its width and length must be greater than or equal to the width of the entrance doorway and shall have a roof on the landing in the same material as on the roof of the dwelling.
• Towing devices:
º Type 1: Manufactured homes are required to remove all towing devices.
º Type 2: Manufactured homes in manufactured home parks that cannot remove towing devices shall be screened by plantings, and the structure shall be skirted.
Historia
(Ord. No. 2025-03, 6-3-2025)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.