(a) Dimensional requirements are as shown in table 3.10, Northlake District dimensional requirements.
(b) Compatibility rules and transitional buffers per article V and section 46-1043 also apply.
Table 3.10 Northlake District Dimensional Requirements Element Northlake District
NL-1 NL-2 NL-3 NL-4
Overall Site Requirements Mixed-use requirement Under 400,000 sq. ft.
of floor area:
None None None None 400,000 sq. ft. or more of floor area:
Min. 2 uses; min. 65% office and/or residential Min. 2 uses; min.
70% industrial None Dwelling units per acre (for residential uses) Controlled by lot size and use regulations.
Open space Sites less than 2 acres:
10% min. 10% min. 10% min. 10% min.
Sites 2 or more acres: 20% min. 20% min. 20% min. 20% min.
Individual Lot Dimensions by Use Non-Residential or Mixed-Use Lot area: 20,000 sq. ft. min. 20,000 sq. ft. min. 30,000 sq. ft. min. 30,000 sq. ft. min.
Lot width: 50 ft. min. 50 ft. min. 50 ft. min. 50 ft. min.
Lot coverage: 80% max. 80% max. 80% max. 80% max.
Table 3.10 Northlake District Dimensional Requirements Element Northlake District
NL-1 NL-2 NL-3 NL-4
Lot Dimensions: Townhouse dwellings Lot area: n/a n/a n/a 1,000 sq. ft. min.
Unit width: n/a n/a n/a 20 ft. min.
Lot coverage: n/a n/a n/a 80% max. (individual lot), 80% max. (overall site) Lot Dimensions: Other residential uses Lot area: 4,000 sq. ft. min. 4,000 sq. ft. min. 4,000 sq. ft. min. 4,000 sq. ft. min.
Lot width: 40 ft. min. 40 ft. min. 40 ft. min. 40 ft. min.
Lot coverage: 80% max. 80% max. 80% max. 50% max.
Setbacks for All Uses (See section 46-1036(c) for additional setback requirements) Front: No min. / 20 ft. max. No min. / 30 ft. max. 20 ft. min. /30 ft.
max.
30 ft. max.
Side (interior): No min. 20 ft. min. 20 ft. min. 7.5 ft. min.
Side (corner): See front See front See front See front Rear: 20 ft. min. 20 ft. min. 20 ft. min. 20 ft. min.
Height Main Buildings: 15 stories max. or 180 ft. max., whichever is less 9 stories max. or 135 ft. max., whichever is less 4 stories or 60 ft.
max, whichever is less 3 stories or 52 ft.
max. whichever is less Parking Decks: 10 stories max. [1] 7 stories max. [1] Table 3.10 Note:
[1] Parking deck height limit applies to both freestanding decks and those incorporated into buildings.
(c) Additional setback requirements.
(1) Buildings may exceed the maximum setback to allow for stoops, front porches, balconies, canopies, or steps, a public space or park, and or outdoor dining.
(2) Parking is not allowed in the front yard or any other yard along public streets (not including 1-285).
(d) Dimensional requirements for each NL-PUD district and development shall be project specific, with the exception of open space requirements, and shall be set by the Master Development Plan as part of the rezoning process.
(Ord. No. O2019-04-15, exh. A(3.3.6), 6-26-2019; Ord. No. O2020-03-07, exh. A, 3-23-2020; Ord. No.
O2024-02-02, Exh. A, 3-11-2024; Ord. No. O2026-04-04, Exh. A, 5-11-2026)