Tucker · Ordenanza de zonificación
Part II - CODE OF ORDINANCES / Chapter 46 / Article III - SPECIAL AND OVERLAY DISTRICT REGULATIONS / Division 2 - DOWNTOWN TUCKER ZONING DISTRICTS
Sec. 46-986. Dimensional requirements.
Sobre este texto
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Dimensional requirements are as shown in table 3.2, Downtown District dimensional requirements.
(b) Compatibility rules and transitional buffers per article V and section 46-993(b) also apply.
Table 3.2 Downtown District Dimensional Requirements Element Downtown District
DT-1 DT-2 DT-3
Overall Site Requirements Dwelling units per acre: Controlled by lot size Controlled by lot size and use regulations
Open space: (development with more than 10% of floor area as residential):
20% min. 20% min. 10% min.
Individual Lot Dimensions by use Non-Residential or Mixed-Use:
Lot area: 5,000 sq. ft. min. 5,000 sq. ft. min. 5,000 sq. ft. min.
Lot width: 50 ft. min. 50 ft. min. 50 ft. min.
Lot coverage: 80% max. 80% max. 90% max.
Lot Dimensions: Townhouse dwellings Table 3.2 Downtown District Dimensional Requirements Element Downtown District
DT-1 DT-2 DT-3
Lot area: 1,000 sq. ft. min. 1,000 sq. ft. min. 1,000 sq. ft. min.
Unit width: 20 ft. min. 20 ft. min. 18 ft. min.
Lot coverage: 80% max. 80% max. 90% max.
Lot Dimensions: Other residential uses Lot area: 6,000 sq. ft. min. 6,000 sq. ft. min. 4,000 sq. ft. min.
Lot width: 40 ft. min. (alley), 50 ft. min. (no alley) 40 ft. min. (alley), 50 ft. min. (no alley) 40 ft. min. (alley), 50 ft. min. (no alley) Lot coverage: 80% max. 80% max. 90% max.
Setbacks for All Uses (See sec. 46-986(c) for additional setback requirements and setback averaging) Front:
Table 3.2 Downtown District Dimensional Requirements Element Downtown District
DT-1 DT-2 DT-3
Lavista Rd. (west of Fellowship Rd.), Hugh Howell Rd., Lawrenceville Hwy Setback averaging applies 5 ft. min. / No max. 5 ft. min. / 20 ft. max.
Lavista Rd. (east of Fellowship Rd.)
5 ft. min. / 20 ft. max. 5 ft. min. / No max. 5 ft. min. / 20 ft. max.
Main St. (block face with pre-1950 building) Setback averaging applies Setback averaging applies Setback averaging applies Main St. (block face
without pre-1950 building) 0 ft. min. / 10 ft. max. 0 ft. min. / 10 ft. max. 0 ft. min. / 10 ft. max.
Other streets Setback averaging applies 0 ft. min. / 20 ft. max. 0 ft. min. / 20 ft. max.
Side (interior): 5 ft. min. 0 ft. min. 0 ft. min.
Side (corner): See front See front See front Rear: 20 ft. min. 20 ft. min. 0 ft. min.
Main Building Height by Use (max.) (See sec. 46-986(d) for more restrictions) Single-family use: 3 stories or 35 ft.,
whichever is less 3 stories or 35 ft., whichever is less 3 stories or 35 ft., whichever is less Other uses (within 200 ft.
of Main St. ROW):
N/A N/A 2 stories or 28 ft., whichever is less Other uses (other locations):
3 stories or 45 ft., whichever is less 4 stories or 60 ft., whichever is less See sec. 46-986(d)(1)
(c) Additional setback requirements.
(1) Street orientation. If a lot is bound by more than one public street, the front of the lot along the primary street will be considered the front. When a building sits on a lot at the intersection of two primary streets, it must be located on the portion of the lot closest to such intersection.
(2) Increased setbacks. When a maximum front setback applies it may be increased when an open space, such as a park or plaza, is provided between the respective building and the adjacent street.
(3) Setback averaging. The following setback averaging applies as shown in table 3.2:
a. Along Lavista Road, Hugh Howell Road, Lawrenceville Highway, and other streets, the minimum front setback is the average front setback of the existing buildings along the same block face, except for those containing institutional/public uses. When no buildings exist on the block face, the minimum setback will be five feet.
b. Along Main Street, on block faces with one or more buildings built before 1950, the maximum front setback is the average setback of the buildings built before 1950 on the same block face.
(d) Height. The following height standards apply in addition to those of table 3.2 or otherwise allowed in this zoning ordinance.
(1) DT-3 district maximum height. The following main and accessory building height standards apply in the DT-3 district:
a. North of Railroad Avenue and west of Burns Avenue (when both are met): max. three stories or 52 feet, whichever is less.
b. All other areas: max. four stories or 60 feet, whichever is less.
(2) Relief limitations.
a. In the DT-2 and DT-3 zoning districts, a special land use permit may be requested to increase the maximum permitted building height up to one additional story or ten feet.
b. Height transitions, such as step backs, transitional height planes, urban street walls, incorporation of natural topography, shall be used to ensure appropriate scale and massing with adjacent and nearby parcels, buildings, green spaces, and trails.
(Ord. No. O2019-04-15, exh. A(3.2.6), 6-26-2019; Ord. No. O2020-03-07, exh. A, 3-23-2020; Ord. No.
O2024-09-17, Exh. A, 10-15-2024)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.