Ir al contenido
Georgia Commons
Menú

Tybee Island · Ordenanza de zonificación

Appendix A - LAND DEVELOPMENT CODE / Article 8 - FLOOD DAMAGE PREVENTION / Division 3 - PROVISIONS FOR FLOOD HAZARD REDUCTION

Sec. 8-190. Specific standards.

Sobre este texto

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

In all areas of special flood hazard designated as A1—30, AE, AH, A (with estimated BFE), the following provisions are required:

(1) New construction and/or substantial improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection 8-180(4), "Elevated Buildings."

(2) Non-residential construction. New construction and/or the substantial improvement of any structure located in A1—30, AE, or AH zones, may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to one foot above the base flood elevation, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and in subsection 8-170(6).

(3) Standards for manufactured homes and recreational vehicles—Where base flood elevation data are available.

a. All manufactured homes placed and/or substantially improved on: (1) individual lots or parcels, (2) in new and/or substantially improved manufactured home parks or subdivisions, (3) in expansions to existing manufactured home parks or subdivisions, or (4) on a site in an existing manufactured home park or subdivision where a manufactured home has incurred "substantial damage" as the result of a flood, must have the lowest floor including basement, elevated no lower than one foot above the base flood elevation.

b. Manufactured homes placed and/or substantially improved in an either existing manufactured home park or subdivision may be elevated so that:

1. The lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation; or

c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement (ref.

subsection 8-180(6) above).

d. All recreational vehicles placed on sites must either:

1. Be on the site for fewer than 180 consecutive days;

2. Be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or

3. The recreational vehicle must meet all the requirements for "new construction," including the anchoring and elevation requirements of subsections (3)a. and c., above.

(4) Floodway. Located within areas of special flood hazard established in section 8-080 are areas designated as floodway. A floodway may be an extremely hazardous area due to velocity floodwaters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply:

a. Encroachments are prohibited, including earthen fill, new construction, substantial improvements or other development within the regulatory floodway. Develop-ment may be permitted however, provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the encroachment shall not result in any increase in flood levels or floodway widths during a base flood discharge. A registered professional engineer must provide supporting technical data and certification thereof.

b. Only if subsection (4)a. above is satisfied, then any new construction or substantial improvement shall comply with all other applicable flood hazard reduction provisions of this division.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 9-26-2008, Art. 4, § B; Ord. No. 2021-19, § I(Att.), 5-27-2021)

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:tybee-island/zoning/8-190@2026-11-11-48892a3af5

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Tybee Island Zoning Ordinance, Sec. 8-190. Specific standards | Georgia Commons