Tybee Island · Ordenanza de zonificación
Appendix A - LAND DEVELOPMENT CODE / Article 8 - FLOOD DAMAGE PREVENTION / Division 3 - PROVISIONS FOR FLOOD HAZARD REDUCTION
Sec. 8-230. Coastal high hazard areas (V-zones).
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Located within the areas of special flood hazard established in section 8-080, are areas designated as coastal high hazard areas (V-zones). These areas have special flood hazards associated with wave action and storm surge, therefore, the following provisions shall apply:
(1) All new construction and substantial improvements of existing structures shall be located landward of the reach of mean high tide;
(2) All new construction and substantial improvements of existing structures shall be elevated on piles, columns, or shear walls parallel to the flow of water so that the bottom of the lowest supporting horizontal structural member (excluding pilings or columns) is located no lower than one foot above the base flood elevation level. All space below the lowest supporting member shall remain free of obstruction or constructed with non-supporting breakaway walls. Open wood lattice work or decorative screening may be permitted for aesthetic purposes only and must be designed to wash away in the event of abnormal wave action and in accordance with subsection below;
(3) All new construction and substantial improvements of existing structures shall be securely anchored on pilings, columns, or shear walls; and
(4) All pile and column foundations and the structures attached thereto shall be anchored to resist flotation, collapse, and lateral movement due to the combined effects of wind and water loads acting simultaneously on all building components, both (non-structural and structural). Water loading values shall equal or exceed those of the base flood. Wind loading values shall be in accordance with the most current edition of the (ICC) International Building Codes;
(5) A registered professional engineer or architect shall certify that the design, specifications and plans for construction are in compliance with the provisions contained in subsection (2) through (4) herein;
(6) All space below the lowest horizontal supporting member must remain free of obstruction. Open wood lattice work or decorative screening may be permitted for aesthetic purposes only and must be designed to wash away in the event of abnormal wave action without causing structural damage to the supporting foundation or elevated portion of the structure. The following design specifications are allowed:
a. No solid walls shall be allowed; and
b. Material shall consist of open wood lattice or mesh screening only;
c. If aesthetic open wood lattice work or screening is utilized, any enclosed space shall not be used for human habitation, but shall be designed to be used only for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises.
(7) Prior to construction, plans for any structures having open wood latticework or decorative screening must be shown on the plans submitted to the city building and zoning department for review and approval;
(8) Any alteration, repair, reconstruction or improvement to any structure shall not enclose the space below the lowest floor except with open wood latticework or decorative screening, as provided in this section;
(9) There shall be no fill used as structural support. Non-compacted fill may be used around the perimeter of a building for landscaping/aesthetic purposes provided the fill will wash out from storm surge (thereby rendering the building free of obstruction), prior to generating excessive loading forces, ramping effects, or wave deflection. The building and zoning department shall approve design plans for landscaping/aesthetic fill only after the applicant has provided an analysis by an engineer, architect, and/or soil scientist, which demonstrates that the following factors have been fully considered:
a. Particle composition of fill material does not have a tendency for excessive natural compaction;
b. Volume and distribution of fill will not cause wave defection to adjacent properties; and
c. Slope of fill will not cause wave run-up or ramping.
(10) There shall be no alteration of sand dunes or mangrove stands, which would increase potential flood damage;
(11) Prohibit the placement of manufactured homes (mobile homes) (Ord. of 9-26-2008, Art. 4, § F; Ord. No. 2021-19, § I(Att.), 5-27-2021)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.