Unadilla · Ordenanza de zonificación
Appendix A - ZONING / Article VI - MOBILE HOME AND MOBILE HOME PARK REGULATIONS
Section 2. Requirements for mobile home parks.
Sobre este texto
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
The following regulations pertain to mobile home parks as defined in article II of this ordinance.
VI.2.1 Site development plan. Complete site development plans of the proposed mobile home park must be submitted to the city council. Site development plans shall include at least the following items:
a. A site plan at a scale no smaller than one inch equals 50 feet.
b. The title under which the development is to be recorded, the legal description of the land to be developed, the name of the present owner, and the name and address of the technical author of the plan.
c. All property lines and dimensions; the location and dimensions of each building and unit.
d. The layout and location of off-street parking, total number of spaces, ingress and egress lanes, pedestrian ways, sidewalks, and curblines.
e. The proposed method of water supply, sewage disposal, storm drainage, and other data as may be required by the planning commission to clearly indicate the general design of said utility services.
f. All proposed uses of the property and buildings to be developed shall be indicated on the plan.
g. Date, north point, and graphic scale.
VI.2.2 Expansion of existing mobile home parks. A person, firm, or corporation desiring to expand an existing mobile home park to include more homes or mobile park sites that [than] are accommodated within such a park at the time this regulation is adopted shall submit plans and specifications for such improvements to the city council for approval prior to initiating construction and improvements.
VI.2.3 Nonconforming mobile home parks. Any nonconforming mobile home park in the City of Unadilla which becomes vacant and remains unoccupied due to abandonment or discontinuance for a period of six months shall not begin new operations until the park is brought into full compliance with these regulations.
VI.2.4 Evidence of compliance. No mobile home shall be admitted to any mobile home park or allowed to be placed within the City of Unadilla for a period exceeding 48 hours unless it can be demonstrated that it meets the requirements of the HUD federal requirements for building construction.
VI.2.5 General development requirements for mobile home parks. Mobile home parks shall conform to the following general requirements.
a. Minimum area: A mobile home park shall have as a minimum size two acres and shall front upon a highway or public street.
b. Minimum number of spaces: A mobile home park shall have as a minimum four spaces prepared with all utilities in place prior to its approval for occupancy.
1. Setback: A mobile home park shall be designed so that mobile homes (and travel trailers, if permitted) and their accessory structures shall be a minimum distance of 15 feet from adjoining property lines, 20 feet from internal park streets and at least 30 feet from any publicly dedicated street.
2. Access: The mobile home park shall front upon at least one publicly dedicated street. Each mobile home site and its parking area shall have direct access to the internal street system of the park.
3. Streets: Streets within a mobile home park shall be either paved or graveled and shall be privately owned, constructed, and maintained. Such private streets shall be well drained, with a minimum width surface of 12 feet for one-way streets and 24 feet for two-way streets.
4. Parking: Each mobile home stand shall be provided with a minimum of one off-street parking space. The front yard space for mobile homes may be used for the parking of motor vehicles; however, the side yard and rear yard space may not be used for parking areas.
5. Density: A maximum of four mobile home stands per gross acre or 12 trailer (travel) stands per acre is allowed.
VI.2.5 [VI.2.6] Improvements required for mobile home stands. The following requirements must be in place prior to habitation of a mobile home park:
a. Interior street access: Each stand shall be provided with access frontage of at least 25 feet for single-wide and 45 feet for double-wide.
b. Electric power supply: Each stand shall be provided with a properly grounded waterproofed electrical receptacle with a minimum rated capacity of 150 amperes. A properly sized over current device shall be installed as a part of each power outlet.
c. Stand identification: A property and street number designation or other appropriate number device properly identifying each mobile home stand shall be placed at the interior side lot line at a point ten to 15 feet from the interior road system of the park.
Such device shall be a minimum of six inches in height.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.