Walls and fences forming trash enclosures

shall be constructed of sturdy, durable, opaque materials (with trash receptacles screened from public view) which are similar to or designed to be compatible with architectural materials used for the principal building on the site it serves.

9.9.6.2 Retaining walls visible from public right-of-way. When retaining walls will be visible from a public right-of-way, the Building Official may limit the height of said retaining wall and may require that any retaining wall of 100 feet or longer be constructed to minimize visual monotony, through changes in plane, height, material, or material texture, or through significant landscape massing.

9.9.6.3 Subdivision or project entrance monuments. All fences or walls comprising a subdivision or project entrance monument shall require plans prepared by a registered landscape architect and are subject to the approval of the Building Official. The city may require fences or walls to incorporate columns or pillars extending at least six inches horizontally and a height at least as high as the height of the fence or wall, every 50 feet of fence or wall length, or to articulate the surface plane wall by incorporating plane projections or recesses having a depth of at least one foot and extending a horizontal distance of at least three feet and less than 20 feet. This articulation requirement shall not apply to a fence or wall of brick, masonry, or metal fencing that consists of at least 50 percent open voids.

9.9.7 Retaining walls. Retaining walls shall be designed to ensure stability against overturning, sliding, excessive foundation pressure and water uplift.

9.9.7.1 Approved materials. Materials for retaining walls shall be limited to: six inches by six inches or larger new pressure treated lumber, precast concrete stone or block, concrete masonry block, or solid poured concrete.

9.9.7.2 Engineered design. Retaining walls greater than 4 feet in height are required to be designed by a professional engineer.

9.9.7.3 Guards. Guards/railings are required along open sided surfaces of retaining walls that are more than 30 inches vertically to the grade below at any point within 36 inches horizontally to the edge or the open side.

9.9.7.4. Height. Required guards/railings shall not be less than 36 inches vertically above the adjacent open sided surface.

9.9.7.5 Opening limitations. Required guards/railings shall not have an opening from the open sided surface to the required guard height which allows the passage of a sphere four inches in diameter.

9.9.7.6 Live load. The minimum uniformly distributed live load capacity of required guards/railings shall be no less than 200 pounds per square foot of applied pressure.