The general standard of residential street lighting for Valdosta, Georgia, is as follows.
8-9.1. Overhead Electrical Distribution: Residential lighting will be provided at intersections, dead-end streets or courts with a maximum spacing not to exceed 500 feet for straight streets, provided spacing shall be reduced as conditions indicate for curved
streets or irregular contours so as to provide adequate lighting. Luminaries are to be 28-foot mounted on existing utility distribution poles and of an approved type mercury unit of approximately 7000 lumen.
8-9.2. Underground Electrical Distribution: Residential lighting will be provided at intersections, dead-ends, or courts with a maximum spacing of 400 feet for straight streets, provided spacing shall be reduced as conditions indicate for curved streets or irregular
contours so as to provide adequate lighting. Luminaries shall be top mounted on 16 feet (approximate) ornamental metal poles of an approved type mercury unit of approximately 7000 lumen.