Chemical manufacturing plants, hazardous waste facilities, recycling plants, fertilizer plants or fertilizer deposit areas (covering an area in excess of 1 acre) or any use that involves the ponding or pooling of liquid industrial waste or liquid chemicals which, in their mixed or unmixed state, are suspected or proven to cause danger to the environment or to human health must be issued a Class 2 special use permit before such uses are made of the property. A Class 2 special use permit for such uses may be issued, provided that all of the following conditions are met:
(1) Application requirements.
a. An application for a Class 2 special use permit must provide the following information:
1. If either the applicant, permit holder, or any owner of the proposed use or facility is a corporation, submit proof that any such corporation is in good standing with the State;
2. The names and addresses of all persons having a legal or equitable ownership interest of at least 1 percent in the business proposing the use;
3. If either the applicant, permit holder or any owner of the proposed use or facility is a corporation, give the names and addresses of all applicable officers and directors;
4. State whether the applicant, permit holder or any owner, director or officer has ever been convicted of a felony, and if so, provide details thereof;
5. State whether the applicant, permit holder, owner or any director or officer has ever been charged, cited or had suit brought against him for violation of any law, rule, regulation or order relating to the protection of the environment;
6. If either the applicant, permit holder or any owner of the proposed use or facility is a corporation, state the name and address of the registered agent for service of process and notices;
7. Submit a detailed list of all judgments and pending litigation, whether or not in the State;
8. Submit a current audited financial statement, prepared according to generally accepted accounting principles, of the applicant, permit holder and owner, showing assets, liabilities, income, expenditures and a budget for the current year;
9. Submit copies of all State and Federal income tax returns of the owner, applicant and/or permit holder for the 3 years preceding the filing of the application;
10. Submit a detailed list of all facilities that the applicant, owner or permit holder owns, operates or uses, which are similar in character to the use or facility for which the application has been made;
11. State whether or not the applicant, permit holder, owner or any officer or director thereof has ever been denied a permit for a use or facility or proposed use or facility similar in character to the use or facility for which the application has been made, and, if so, provide details thereof;
12. Provide copies of all necessary applications and permits, licenses and approvals from State and Federal environmental regulatory agencies for the use or facility for which the application was made.
b. The application shall be accompanied by a plan, drawn to scale, showing the proposed location of the various different uses of the property, boundary lines, dimensions of the property, names of owners of abutting properties, location of proposed roads, parking facilities, structures, a topographical map and grading plan, the type and location of drainage, sewerage, water and other utilities to serve the proposed facility.
c. The Planning Commission may require such other plans, data, specifications, engineering reports, designs and other information it deems necessary, at the cost of the applicant, to make a determination of compliance with this subdivision.
(2) Conditions of issuance.
a. A Class 2 special use permit may be issued, provided that all of the following conditions are met:
1. Adequate space for off-street parking shall be provided.
2. A 500-yard setback buffer distance shall be maintained from the nearest building line of the nearest dwelling.
3. A 250-yard setback buffer distance from the nearest building line of a non-dwelling building structure used for human occupancy (such as businesses, industrial buildings, commercial offices, etc.) must be maintained.
4. A 100-yard setback buffer distance from private property lines shall be maintained for aesthetic reasons.
5. Other provisions of this chapter (including, but not limited to, type of zoning at the site, setback buffers and screening) applying to the particular use and the type of use shall be complied with.
6. Such use shall not occur within a two-mile radius of the most significant groundwater recharge areas shown on the comprehensive plan.
7. The use shall be consistent with the comprehensive plan for the area.
8. The proposed use must be able to be served by adequate public utilities.
9. Adequate traffic routes and entrances must be established, including consideration of the deterioration of the existing roadway, expenditure of public funds to maintain roadways, adequacy and safety of road intersections, road widths on roads within and leading to the property, pavement conditions (material, thickness, age, etc.), width and length of property boundaries at road access areas and type of vehicles that may be used at the property.
10. The lot size must be sufficient in order to provide the operational space needed for the proposed use to carry out all business-related transactions without infringing on setback and other requirements of this chapter.
11. The owner and/or permit holder must provide adequate screening of the entire premises. The screening must effectively screen the premises on a year-round basis and must be compatible with the facility's surroundings. All screening must meet the criteria set forth in section 22-322(e) and (f).
b. Once the Planning Commission shall have determined that all of the foregoing requirements have been satisfied, it must further find that the benefits of and need for the proposed use are greater than any possible depreciating effects and damages to the neighboring properties before a Class 2 special use permit for such use can be granted.
c. Each Class 2 special use permit shall contain such terms and conditions as are deemed necessary by the Planning Commission to protect the environment, public health and safety. The Planning Commission may require such testing and construction supervision as it deems necessary to protect the environment and public health and safety.
(3) Financial responsibility.
a. No Class 2 special use permit shall be issued to any person, and no facility requiring a Class 2 special use permit shall be constructed, operated, maintained, modified or sold by any person unless such person can demonstrate financial responsibility for taking corrective action and for compensating a third party for bodily injury and property damage in an annual aggregate amount of $5,000,000.00. The required annual aggregate coverage amount does not in any way limit the liability of the owner or the operator. The owner or operator may use any 1 or combination of the following mechanisms to demonstrate financial responsibility, to wit:
1. Surety bond; or
2. Irrevocable letter of credit.
b. An owner or operator must maintain evidence of all financial assurance mechanisms used to demonstrate financial responsibility until released from the requirements of this subsection (3) of this section by the Commission.
Historia
(Code 2005, § 34-382; Ord. of 7-20-1994, § 7.01)