The level of service provided by culverts and pipe systems in Whitfield County, City of Dalton, City of Tunnel Hill and the City of Varnell is dependent on a number of different factors. These include the type of road that the system will service, the potential for upstream flooding, floodplain impacts and other service issues. Generally, the level of service to be provided by culverts is outlined in the table below:

Roadway Classification/Use Design Storm Emergency Access Routes (To be Determined by County Engineer) 100-Year Collector Roadways 50-Year Local Roads 25-Year Roads with No Other Outlet 100-Year Parking Lot/Material Storage Areas/Landscape Areas 10-Year The level of service standards outlined above are considered minimum standards, where warranted the level of service may be increased at the discretion of the designer. For determining the maximum allowable head at any structure, the hydraulic grade line (HGL) should be designed to no less than six inches below the elevation of the inlet (catch basins, yard inlets, drop inlets, hooded grate inlets, etc.).

The HGL should be designed to no less than six inches below the rim elevation for all junction boxes.

Other inlets such as headwalls, flared end sections, etc. should be designed based on the guidance outlined in section 2.2.4 of the LDM.

Culverts with contributing drainage areas greater than 25 acres shall be designed to the 24-hour storm. For example, if a culvert is to be designed to convey stormwater runoff from a 25-acre drainage basin under a neighborhood road, the design storm shall be a 25-year, 24-hour storm. If a culvert is designed to connect to an existing system of a differing design level of service, then the system with the greater design requirement will be used to size the proposed system.

All pipes should be designed to maintain a minimum velocity of three feet per second during the 2-year design storm to promote sediment removal.

2.2.3. Inlets (catch basins, yard inlets, drop inlets, hooded grate inlets and flumes).

Inlets collecting stormwater runoff from street surfaces and area inlets shall be sized to capture the storm event specified for the pipe system to which it drains and a maximum flooding depth as determined by the following table:

Roadway Classification/Use Design Storm Flooding Depth Emergency Access Routes 100-Year 8.0 ft. Maximum Gutter Spread Collector Roads 50-Year 8.0 ft. Maximum Gutter Spread Local Roads 25-Year 8.0 ft. Lane Width Open Roads with No Other Outlet 100-Year 8.0 ft. Lane Width Open Parking Lots (with a check of the 100-year storm flooding depth and maximum 1-foot depth) 10-Year Maximum 0.5 ft. Depth Detention Areas utilized for other purposes with general public access (i.e. parking lot detention, etc.) with flood warning sign 100-Year Maximum 1.5 ft. Depth Material Storage Areas/ Landscape Areas with flood warning sign if area is utilized by the public (with a check of the 100-year storm flooding depth) 10-Year Maximum 2.0 ft. Depth Inlets and grading adjacent to habitable structures shall be designed to prevent stormwater runoff from entering the structure during the 100-year design storm.

In no case shall inlets located on public streets be spaced in excess of the following table:

Road Grade Maximum Distance Between Inlets 0.00% to 7.00% 400-feet 7.01% to 10.00% 300-feet 10.01% and Greater 250-feet