Whitfield County · Ordenanza de zonificación
Appendix C - STORMWATER LOCAL DESIGN MANUAL
3.1.4. Other pipe systems in the City of Dalton.
Sobre este texto
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
Pipe systems not within the public right-of-way of the City of Dalton but in the city limits of Dalton shall be constructed of RCP, HDPE, or CMP meeting Georgia Department of Transportation Standards and approved by Whitfield county engineer. Non-RCP pipe will be allowed if all of the following conditions are met: (1) Pipe is not located within private street right-of-way, (2) pipe does not directly connect to the City of Dalton's MS4 system, and (3) pipe does not receive stormwater drainage from City of Dalton right-of-way. Exceptions may be granted upon submittal of a site specific request and approval by City of Dalton prior to construction. Minimum bedding standards for HDPE pipe and CMP shall be such that stone bedding (i.e. No. 57 stone) shall be placed to half of the pipe diameter for all depths greater than four feet and/or in accordance with manufacturer's specifications, whichever is greater.
All pipes must have a minimum of 12 inches of cover from the exterior crown of the pipe, and in accordance with manufacturer's specifications. Pipes under pavement must have a minimum of 12 inches of cover from the exterior crown of the pipe to the bottom of the roadway base. The minimum cover for pipes which run along individual lot property lines in residential developments shall be increased to three feet to account for the potential for damage due to residential fence construction.
All CMP shall be galvanized or aluminum coated (Type 2) steel pipe. Galvanized steel pipe must be galvanized with a minimum of four ounces of galvanization per square foot, and have three inch by one inch corrugation for pipe sizes of 36 inches in diameter and larger, and be 14 gauge or heavier construction. Aluminum coated (Type 2) must use steel sheet for corrugated steel pipe that meets AASHTO M 274M requirements. Those areas where a high ground water table exists and/or soil corrosivity and resistivity do not meet manufacturer's recommendations for a 50-year service life, only RCP may be utilized. The county engineer may, at its discretion, require soil tests to be provided at the owner's expense to determine corrosivity and resistivity of the soils as well as the presence and depth of the groundwater table. All soil tests performed by the owner must be performed in strict conformance with pipe manufacturer's specifications.
Maximum deflection of installed pipe systems shall be in accordance with manufacturer's specifications.
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.