Sec. 3-2. Residential design standards.

Sobre este texto

  • As published by Municode, current through 2026-08-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

A. All residential buildings (including all detached single-family dwellings, cottage courts, duplexes, townhouses, and multifamily buildings) in any zoning district shall be subject to the standards of this section, unless alternate standards are approved by City Council. Accessory buildings shall be subject to only the exterior wall requirements of this section, except in agricultural districts, where accessory buildings shall be exempt from all requirements of this section.

B. Exterior walls. The following standards apply to all exterior walls.

1. Exterior wall finish materials (excluding windows, doors, trim, soffits, porches, balconies, foundations, or architectural details) are limited to the following:

i. Brick, including full-depth and half-depth masonry brick, but not simulated brick veneers;

ii. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta;

iii. Stucco, including true cement stucco but not EIFS;

iv. Wood, including natural wood, engineered wood, or cementitious siding; and

v. Shingles, including wood or cementitious shakes and shingles.

2. Where more than one exterior finish material is used, visually lighter materials must be used above visually heavier materials.

3. Between two and four different exterior finish materials, textures, colors, or combinations thereof must be used on a single building, excluding materials used on windows, doors, porches, balconies, foundations, or architectural details.

4. Foundation when visible must be constructed as a distinct building element that is finished in a different material or color. Above-ground foundations must be coated or faced in brick or stone.

5. Single Family detached units, townhouse units and condominium units shall not have identical units adjacent to each other. Differentiation between adjacent façades may be accomplished by a change in materials, building height, color, roof form or architectural styles.

6. Single family detached units, townhouse units and condominium units shall have a minimum of twenty-four (24) inches of brick or stone on all sides, measured from where the final grade of the lot meets the outside of the building.

i. Slab Foundations: For buildings with slab foundations, the measurement of the minimum required brick or stone on all sides shall commence from the point where the final grade of the lot intersects the exterior walls of the building. This measurement shall be taken vertically from said point, without regard to any variations in slope or elevation across the lot.

ii. Sloped Foundations: In the case of buildings featuring a sloped foundation or located on lots with uneven terrain, the measurement of the required minimum brick or stone shall be adapted to accommodate the topography. Should the final grade of the lot exhibit variations due to slope, the minimum required brick or stone shall be adjusted to ensure a consistent measurement from the point at which the final grade meets the exterior of the building. In such circumstances, this measurement shall follow the contour of the slope to maintain the intended architectural and aesthetic consistency.

C. Windows and doors. The following standards apply to all street-facing exterior walls.

1. The total area of all windows on an individual story must not be less than 10%, nor greater than 50%, of the total exterior wall area for that story. Total exterior wall area shall include the area of garages and other doors.

2. Doors and windows that operate as horizontal sliders are prohibited as building front walls.

3. Individual windows must be vertically shaped, with a height greater than width.

4. Windows must have true or simulated divided lites, or be one-over-one lites.

5. Transom windows are permitted, but do not need to be vertically shaped, have divided lites, or include a sill.

6. Window panes must be recessed a minimum of 1 inch from the face of the exterior wall where no trim is provided, or a minimum of 1.5 inches from the face of the trim where trim is provided.

D. Porches and stoops.

1. Any porch shall have minimum dimensions of four feet by eight feet for porches, and any stoop shall have minimum dimensions of four feet by four feet.

E. Roofs and chimneys.

1. Pitched roofs, if provided, must be symmetrically sloped at no less than 5:12, except that roofs for front porches and attached sheds may be sloped at no less than 2:12.

2. Flat roofs shall be enclosed by parapets a minimum of 42 inches high, or as required to conceal mechanical equipment.

3. All exposed roofing materials must have a minimum 25 year manufacturer's warranty and no visible roll roofing.

4. Eaves and overhangs. Eaves and gables on pitched roofs must extend a minimum of 12 inches beyond the façade.

5. Chimneys, where provided must extend to the ground and must be faced in brick, stone, cast stone or hard coat stucco or cementitious siding.

F. Garages and carports. The following standards shall apply to all residential types except for multifamily residential.

1. For lots with alley access, the garage or carport shall be placed to the rear of the dwelling unit or incorporated into the dwelling unit with the garage door or vehicular opening facing the alley.

2. Garage doors that face a public or private street may not be more than 50% of the overall width of the front façade.

3. Garage doors that face a street must be separated by at least 12 inches of material identical to the adjacent exterior wall material.

4. Each detached and attached single family residential unit shall have a garage, enclosed on at least 4 sides, of at least 500 square feet of interior clear space as measured outside wall to outside wall. The garage must meet the following standards:

i. All garages on single-family detached and attached residences shall be able to accommodate two standard vehicles.

ii. A garage, whether detached or attached, shall not be enclosed to be used as living space unless other accommodations are approved for an enclosure that meets these garage requirements.

iii. Clear space shall not include utility and storage offsets.

G. Driveway standards.

1. Slope. The maximum slope for all driveways shall be 10%. (Site grading requirements are provided in Section 3-6.)

2. Minimum length for driveways. Driveways shall be at least 25 feet between the garage door and sidewalk, where sidewalk is required or exists. If sidewalks are not required or does not exist, driveways shall be at least 25 feet between the garage door and the back of curb.

3. Shared driveways in residential developments shall not be permitted.

4. Driveways shall not count towards overall parking requirements within a development.

H. Additional standards for multifamily residential developments, excluding townhouse developments.

1. All dwelling units above the first floor shall have balconies with minimum dimensions of four feet by eight feet.

2. Interior floor to ceiling height for all floors shall be a minimum of 9 feet.

J. No more than 6 townhouse units may be connected in a single structure.

K. Solar Panels.

1. Solar panels are permitted and shall be placed on the rear of the building or back side of roof when feasible.

2. Permit Required. A permit is required for all solar panels. Applications for solar panels on historic properties, as defined in Chapter 19, require approval from the historic preservation commission.

Reuniones que se refieren a esta sección

Encontradas: 8. Son reuniones de este gobierno cuyas actas o transcripciones automáticas nombran esta sección, o una ordenanza de su línea de historia, de la más reciente a la más antigua. Halladas por regla a partir de las propias palabras de esos registros. Una referencia es un enlace a otro registro, no una afirmación de que la sección se aplica o se cambió.

Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:winder/zoning/3-2@2026-08-03-0f1f657b90

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Winder Zoning Ordinance, Sec. 3-2. Residential design standards | Georgia Commons