Sec. 3-218. Cross drainpipes.
Sobre este texto
- As published by Municode, current through 2022-10-28
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
(a) Cross drainpipes shall be no less than 15 inches in size when under the street. No storm drainpipe running parallel to the existing primary road shall be located beneath the proposed acceleration/deceleration lanes. The city may modify or waive this requirement if unusual circumstances exist such as topography.
(b) Maximum continuous length of pipe shall be 300 feet for pipes less than 42 inches.
(c) Junction boxes having access to the pipe shall be constructed to meet the requirements of GDOT Standard 1030D (or most current).
Historia
(Ord. of 5-17-2021(1))