Woodbury · Ordenanza de zonificación
Appendix A - ZONING / Article 4 - LOT AND BUILDING STANDARDS / Division III - DIMENSIONAL REQUIREMENTS
Division III. DIMENSIONAL REQUIREMENTS
Sobre este texto
- As published by Municode, current through 2022-10-28
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.
All Zoning Districts established by this Ordinance shall be provided with a specific set of dimensional requirements which are considered to be appropriate for such districts. These requirements shall govern development within said District unless otherwise specifically provided for by this Ordinance. Such dimensional requirements shall be generally provided in a table within this Article or within text elsewhere in this Ordinance. Dimensional requirements may include, but not necessarily be limited to, the following described in this Division.
(Ord. of 7-15-2019) Sec. Z4-19. Lot Area.
Minimum lot area requirements provide standards to create lots that promote development consistent with the desired character of the district in which they are applied. Minimum lot area requirements are as follows:
A. Residential Lot Area.
1. Every property upon which an allowed use in a residential zoning district will be located shall meet or exceed the requirements shown on Table 4-A for the zoning district in which the lot is situated.
2. The minimum lot area must be met by each lot in a conventional subdivision. See the Article 6, Master Planned Developments for lot area reductions in conservation subdivisions. In addition, requirements may differ for Planned Development Districts and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
B. Non-residential Lot Area.
1. Every property upon which an allowed use in a commercial zoning district will be located shall meet or exceed the requirements shown on Table 4-B for the zoning district in which the lot is situated.
2. Every property upon which an allowed use in an industrial zoning district will be located shall meet or exceed the requirements shown on Table 4-C for the zoning district in which the lot is situated.
3. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See the Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-20. Maximum Density.
A. Maximum density requirements (net or gross density) provide standards for residential density expressed in the number of units per acre and are shown on Table 4-A. Such standards promote development consistent with the desired character of the district in which they are applied.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-21. Minimum Building Line Width.
A. Minimum building line width requirements are shown in Table 4-A, Table 4-B, and Table 4-C. These requirements are provided to ensure that lots provide sufficient space between buildings, structures, and other site elements located on lots; to ensure that a reasonably sized building can be located on a lot along with required side yard setbacks and buffers; and for other purposes.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-22. Minimum Lot Frontage.
A. Minimum lot frontage requirements are shown in Table 4-A, Table 4-B, and Table 4-C.
These requirements are provided to ensure that lots are wide enough to allow for access and for other purposes.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-23. Minimum Lot Depth.
A. Minimum lot depth requirements are shown in Table 4-A, Table 4-B, and Table 4-C.
These requirements are provided to ensure that a reasonably sized building can be located on a lot along with required front and rear yard setbacks and buffers and for other purposes.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-24. Minimum Principal Living Space.
A. Principal living space requirements are shown in Table 4-A and Table 4-B. These requirements are provided to ensure that adequate space is provided for an individual or family unit and to promote development consistent with the desired character of the district in which they are applied. Principal Living Space (listed as "Living Space, Principal") is defined in Article 13, Interpretation and Definitions.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-25. Maximum Building Coverage.
A. Maximum building coverage requirements are shown in Table 4-A, Table 4-B, and Table 4-C. These requirements limit the footprint of buildings, promote development consistent with the desired character of the district in which they are applied, and—in coordination with Floor Area Ratio (FAR), height, and setback standards—guide the overall scale of development.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-26. Floor Area Ratio (FAR).
A. Floor area ratio (FAR) requirements are shown in Table 4-A, Table 4-B and Table 4-C.
These requirements are used to control the bulk of development on a piece of land. Floor area ratio is defined in Article 13, Interpretation and Definitions and calculated in this Article.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-27. Minimum Open Space.
Open Space, as defined in Article 13, Interpretation and Definitions and described in this Article, is required for developments with 25 or more units or lots per Table 4-A of this Article and in accordance with the following requirements:
A. Open Space may include parks, commons, plazas, community green or lawn, landscaped buffers or other areas, decorative plantings, formal or informal gardens, pedestrian walkways or paths, and active or passive recreation areas.
B. Open Space shall not include streets, drives, off-street parking and loading areas or any area within residential lots.
C. No more than 40% of the required Open Space shall be located within floodplains, wetlands, steep slope areas, utility easements, etc.
D. All Open Space shall be a minimum dimension of 50 feet in length and width and shall comprise a contiguous area of not less than 5,000 square feet.
E. Open Space shall be maintained by and be the sole responsibility of the developer/ owner of the project or homeowner's association.
F. See Sec. Z4-17, Open Space for an explanation of how to calculate Open Space.
G. Open Space requirements may differ for Planned Development, Open Space, or MixedUse Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-28. Minimum Setbacks; Principal Buildings.
Setbacks promote streetscapes and development layout that are consistent with the character of the district in which they are applied.
A. Minimum setback requirements for principal buildings are shown in Table 4-A, Table 4-B, and Table 4-C.
B. The following elements shall not encroach into required setbacks: principal buildings including covered porches, attached garages, and covered decks.
C. The following projections are allowed into required yards in residential zoning districts:
1. Uncovered Similar Structures. For uncovered porches, landings, terraces, patios, platforms, or decks which do not extend above the first-floor level of the building, refer to Article 3, Restrictions on Particular Uses.
2. Architectural Features. Chimneys, cornices, eaves, belt courses, sills, canopies or similar architectural features (not including bay windows or vertical projections) may project into a required side yard not more than 30 inches, but not closer than 3 feet to the side lot line and may project into a required front or rear yard not to exceed 3 feet.
3. Heating and Cooling Equipment. Heating and cooling equipment may project only into any required side or rear yard provided that such equipment may not be located closer than 3 feet from any side or rear lot line.
4. Swimming Pools. For swimming pools, refer to Article 3, Restrictions on Particular Uses.
D. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
(Ord. of 7-15-2019) Sec. Z4-29. Building and Structure Heights.
A. Height Limitations. No building or structure may exceed the height limitations for principal or accessory buildings or structures as provided under the regulations of the districts herein except that:
1. These limitations shall not apply to public utility poles and lines; skylights, roof structures for elevators; stairways; tanks; heating, ventilating, or air-conditioning equipment; or similar equipment used solely for the operation and maintenance of a building and shall be applied to any device used to screen such structures and equipment.
2. The following structures are allowed above the height limit adjacent to non-residential uses: decorative towers, cupolas, residential chimneys, spires, flag poles, monuments, smoke stacks, or other similar structures, and necessary mechanical appurtenances;
except that gross height may be limited by other jurisdiction agencies. If adjacent to a residential use, then the part of the structure above the height limit shall be separated from any abutting residential lot line by a distance equal to its height measured from the ground.
3. See Article 3, Restrictions on Particular Uses for height requirements for telecommunications towers.
B. Height Requirements; Principal Buildings.
1. Maximum height requirements for principal buildings are shown in Table 4-A, Table 4-B, and Table 4-C. These requirements are intended to control the overall scale of buildings. Height is defined in Article 13, Interpretation and Definitions.
2. On properties abutting existing development, materials used on structures built higher than the normal allowable height must use materials that will complement those used on adjacent buildings.
3. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
C. Height Requirements: Accessory Buildings and Structures. See Article 3, Restrictions on Particular Uses.
(Ord. of 7-15-2019) Sec. Z4-30. Transition Districts.
A. Description and Purpose. A Transition District shall be established on any nonresidential parcel or parcels where such non-residential parcel or parcels abuts or is within a minimum distance from a single-family residential use. Such a District shall require special conditions of development to minimize incompatibility and detrimental effects of such uses with the residential uses.
B. Dimensional Requirements.
1. Setbacks.
a. Front or Street Side. Where a non-residential use is located across a street right-of-way from a single-family residential use or where such a use is located across a street right-of-way from a block that contains more than one-half of its frontage in single-family residential uses, the setback shall be equal to or greater than the setback required of the single-family residential use. However, where such street right-of-way is 60 feet or more in width, this requirement shall not apply.
b. Side. Where a non-residential use is located adjacent to or abuts a single-family residential use, the setback shall be equal or greater than twice the setback required of the single-family residential use.
c. Rear. Where a non-residential use is located to the rear of a single-family residential use, the setback shall be equal or greater to the setback required of the single-family residential use.
2. Height Restrictions. For a distance of 200 feet from any single-family residential property line, no portion of any building or structure shall exceed a height of 1 foot for each 1 foot in distance from said property line, except that no building shall be restricted to a height of less than 15 feet.
C. Buffers and Screening. The following requirements shall apply to all non-residential uses adjacent to and for a distance of 200 feet from the line of any single-family residential property line:
1. Screening. All sales, service, storage, or display areas; all ingress/egress, parking, or loading areas; and all garbage collection areas shall be effectively screened with a solid masonry wall, solid wood fence, or planted evergreen screen of not less than 6 feet in height.
2. Buffers. A Type "C" buffer, as specified In the City's Tree Preservation and Landscaping Ordinance, shall be provided adjacent to all single-family residential uses except that a Type "A" buffer, as specified in the Tree Preservation and Landscaping Ordinance within the City of Woodbury Code of Ordinances, may be substituted in the CBS and CNH Districts.
D. Other Requirements. The following requirements shall apply to all non-residential uses adjacent to and for a distance of 200 feet from any single-family residential property line:
1. Sign Limitations.
a. No free-standing sign shall exceed a height of 6 feet.
b. No sign shall be illuminated except by indirect means.
c. No sign shall consist of flashing or intermittent pulses.
d. No sign shall be visible from a single-family residential property which abuts the rear of an abutting or adjacent non-residential use.
e. No sign which is attached to a building shall be visible from a single-family residential property which abuts the rear of an abutting or adjacent nonresidential use.
2. Lighting Limitations. Lights shall be so shielded and directed as to prevent glare into a single-family residential district.
(Ord. of 7-15-2019) Sec. Z4-31. Requirement Tables.
A. Table 4-A, Table 4-B, and Table 4-C show dimensional requirements for residential, commercial and industrial zoning districts.
B. Requirements may differ for Planned Development, Open Space, and Mixed-Use Districts. See Article 6, Master Planned Developments for these requirements.
C. Additional standards guiding the development of property may also apply, including, but not limited to, requirements in Article 3, Restrictions on Particular Uses.
City of Woodbury Official Zoning Map 7-15-2019 Table 4-A: Residential Dimensional Requirements
DIMENSION %
ZONING DISTRICT
RS-20 RS-15 RS-7 RO-1 RO-2 RML RMH
Minimum/Maximum District Size (Square Feet/Acres) 1 Acre Minimum 1 Acre Minimum One-Half (0.5) Acre Minimum One-Half (0.5) Acre Minimum 16,000 sf Minimum 60 Acres Maximum 40 Acres Maximum Minimum Lot Size (Square Feet/Acres) 26,000 15,000 Detached=7,500 Townhouse=3,000 Average of Platted Lots Existing on Block Detached=7,500 Townhouse=2,600 Multifamily=1 Acre Townhouse=2,600 Detached=7,500 Manufactured=6,000 Multifamily=1 Acre Townhouse=2,600 Detached=7,500 Manufactured=6,000 Base/Maximum Density (Units/Acre)
1.5 2.5 4 Varies, based on lot size 5 Multifamily=8 Other=6 Multifamily=12 Other=8 Minimum Front Setback1 Major St.=50/100 Minor St.=35/60 Major St.=45/95 Minor St.=30/55 Major St.=40/90 Minor St.=25/50 w/Rear Garage=10/35
Average of adjacent units or block average Major St.=35/85 Minor St.=20/45 w/Rear Garage=10/35 Multifamily Major St.=100/150 Minor St=50/100 Other Major St.=30/80 Minor St.=15/40 w/Rear Garage=10/35 Multifamily Major St.=100/150 Minor St.=50/100 Other Major St.=30/80 Minor St.=15/40 w/Rear Garage=10/35 Minimum Side Setback2 (Feet) 15' 12' 10' Average of adjacent units or block average 7' Multifamily=12' Other=7' Multifamily=12' Other = 7' Minimum Street Side Setback3 (Feet) Major St=50/100 Minor St=35/60 Major St.=45/95 Minor St.=30/55 Major St.=40/90 Minor St.=25/50 w/Rear Garage=10/35
Average of adjacent units or block average Major St.=35/85 Minor St.=20/45 w/Rear Garage= 10/35 Multi-family Major St=100/150 Minor St.=505/100 Other Major St.=30/80 Minor St.=15/40 w/Rear Garage=10/35 Other Major St.=30/80 Minor St.=15/35 w/Rear Garage=10/35 Minimum Rear Setback (Feet) 40' 35' 30' Average of adjacent units or block average 20' Multifamily=40' Other=20' Multifamily=40' Other=20' Minimum Building Line Width (Feet) 100' 85' Detached=75' Townhouse=30' Average of adjacent units or block average Detached=75' Townhouse=26' Multifamily=300' Condo=100' Detached=75' Townhouse=26' Multifamily=400' Condo=100' Detached=75' Townhouse=26' Minimum Lot Frontage4 (Feet) 100' 35' cul-de-sac 85' 35' cul-de-sac Detached=75' Townhouse=30' Average of adjacent units or block average Detached=75' Townhouse=26' Multifamily=300' Condo=100' Multifamily=400' Condo=100' Detached=75' Minimum Lot Depth (Feet) 100' 100' 90' Average of adjacent units or block average 90' 80' 80' Minimum Principal Living Space (Square Feet) 2,000 1,800 1,600 Average of Units Existing on Block 1,500 Studio=500 1 Bedroom=700 2 Bedroom=950
3+ Bedroom=100 Other=1500 Studio=500 1 Bedroom=700 2 Bedroom=950 3+ Bedroom=1100 Other=1500 Maximum Principal Building Height (Feet) 35' 35' 40' Average of adjacent units or block 40' 45' 45' Accessory Building Height6 15' 15' 15' 15' 15' 15' 15'
DIMENSION %
ZONING DISTRICT
RS-20 RS-15 RS-7 RO-1 RO-2 RML RMH
Maximum Building Lot Coverage5 (Percent) 20% 30% Detached=50% Other=70% 35% Detached=50% Townhouse=70% Condo=25% Multifamily=25% Condo=25% Detached=50% Manufactured=50% Other=70% Multifamily=25% Condo=25% Detached=50% Manufactured=50% Other=70% Base/Maximum Floor Area Ratio (FAR)
N/A N/A N/A N/A N/A N/A N/A
Minimum Distance Between Buildings (Feet) 10' 10' 10' 5' 10' Multifamily=20' Other=10' Multifamily=20' Other=10' Pedestrian Orientation
(See Sec. Z4-10) Class I Class I Class II Class II Class II Class II Class II Open Space7 (Square feet per dwelling unit) N/A 1,000 1,000 1,000 1,000 1,000 1,000
NOTES:
1 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used.
2 A 10-foot setback shall be required at the end of a series of attached units except that when separated by an alley, no setback shall be required.
3 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used. Street side may refer to the side of the residence or to the rear of the residence.
4 Unless otherwise denoted, all lots which front completely on the turnaround of a cul-de-sac shall have a minimum 30' of frontage.
5 Is not applicable to loft style apartments/condominiums.
6 Accessory building height shall be a maximum of 18' for garage apartments.
7 Applies to developments with 25 lots/units or greater. See Sec. Z4-27, Minimum Open Space.
Table 4-B: Residential Dimensional Requirements
DIMENSION %
ZONING DISTRICT
OI-1 OI-2 CNH CSC CBS CGN CHV
Minimum/Maximum District Size (Square Feet) 22,500/None 2 acres/None 10,000 90,000 43,560/None None 22,500/None 22,500/None Minimum Lot Size (Square Feet) 22,500 30,000 5,000 43,560 None 22,500 22,500 Base Density (Units/ Acre) N/A N/A None N/A None N/A N/A Front Setback1 (From Street, in feet) Major St.=50/100 Minor St.=40/70 Major St.=50/100 Minor St.=40/70 None Major St.=40/100 Minor St.=20/60 None Major St.=35/85 Minor St.=35/65 Major St.=40/100 Minor St.=40/70 Side Setback (Feet) 12' 15' None, except 10' adjacent to residential land 10' None, except 10' adja- cent to residential land 12' 15'* Street Side Setback2
(From street, in feet) Major St.=50/100 Minor St.=40/70 Major St.=50/100 Minor St.=40/70 None Major St.=30/80 Minor St.=20/60 None Major St.=35/85 Minor St.=35/65 Major St.=40/100 Minor St.=40/70
DIMENSION %
ZONING DISTRICT
OI-1 OI-2 CNH CSC CBS CGN CHV
Rear Setback (From Street) 30' 40' None 40' None 12' 40' Minimum Building Line Width (Feet) 125' 50' cul-de-sac 150' 50' cul-de-sac 15' 150' 15' 125' 50' cul-de-sac 125' Minimum Lot Frontage (Feet) 50' 100' 15' 150' 15' 125' 125' Minimum Lot Depth (Feet) 125' 150' None 150' None 150' 150' Minimum Principal Living Space (Square Feet) N/A N/A Studio=500 1 Bedroom=750 2 Bedroom=900
3+ Bedroom=1,050 N/A Studio=500 1 Bedroom=750 2 Bedroom=900 3+ Bedroom=1,050
N/A N/A
Principal Building Height 3 (Feet) 35' 75' 35' 40' 45' 40' 40' Accessory Building Height See Article 3, Restrictions on/Particular Uses 14' 14' 14' 14' 14' 14' 14' Minimum/Maximum Building Coverage (Percent) None/25% None/70% 50%/95% None/35% 50%/100% 4 None/35% None/35% Base/Maximum Floor Area Ratio (FAR) 0.40/0.70 0.75/2.00 1.00/2.00 0.50/1.00 3.00/4.00 5 0.50/1.00 0.50/0.90 Distance Between Buildings (Feet) 20' 20' 20' 20' None 20' 20' Pedestrian Orientation See Sec. Z4-10, Pedestrian Orientation.
Class I Class I Class II Class I Class II Class I Class II Ground Floor Window Standards Apply See Article 3, Restrictions on Particular Uses No No Yes No Yes No No
NOTES:
1 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used.
* Except that for uses that require a buffer, a side yard width must be sufficient enough to absorb the size of the buffer.
2 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used. Street side may refer to the side of the Principal Building or to the rear of the structure.
3 See Sec. Z4-29, Building Structure and Heights for height allowances for non-residential structures located within the Whitehouse Parkway corridor.
4 For CBS lots of 30,000 square feet or greater, building coverage shall be limited to a maximum of 70% and shall include a minimum of 10% open space.
5 For CBS lots of 30,000 square feet or greater, FAR shall be limited to a base of 1.50 and an aggregate maximum of 2.25.
Table 4-C: Industrial Dimensional Requirements
DIMENSION ZONING DISTRICT
ILT IHV PIP
Minimum District Size (Acres) 1 2 5 Minimum Lot Size (Square Feet) 43,560 87,120 43,560 Front Setback1 (Feet) Major St.=35/85 Minor St.=35/65 Major St.=40/100 Minor St.=40/65 Major St.=35/85 Minor St.=35/65 Side Setback (Feet) 12' 30' 12' Street Side Setback2 (Feet) Major St.=35/85 Minor St.=35/65 Major St.=40/100 Minor St.=40/65 Major St.=35/85 Minor St.=35/65 Rear Setback (Feet) 15' 40' 15' Minimum Building Line Width (Feet) 200' 200' 200' Minimum Lot Frontage (Feet) 200' 200' 200' Minimum Lot Depth (Feet) 200' 200' 200' Principal Building Height (Feet) 35' 35' 35' Accessory Building Height (Feet) 35' 35' 35' Maximum Building Coverage (Percent) 70% (Lot) 60% (Lot) 70% (Lot) Base/Maximum Floor Area Ratio (FAR) 0.50/0/70 0.30/0.50 0.50/0.70 Distance Between Buildings (Feet) 20' 25' 20'
NOTES:
1 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used.
2 Note that the first number refers to the distance to be set back from the public right-of-way and the second number refers to the distance to be set back from the centerline of the road or street. Both numbers shall be considered when calculating setbacks and the larger number used. Street side may refer to the side of the Principal Building or to the rear of the structure.
Historia
(Ord. of 7-15-2019)
Leer este código donde se publica (Municode) La fuente es el código de la ciudad tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.