Ir al contenido
Georgia Commons
Menú

Barrow County · Código de ordenanzas

Part II - CODE OF ORDINANCES / Chapter 22 - BUILDINGS AND BUILDING REGULATIONS / Article II - CONSTRUCTION CODES / Division 3 - PERMITS

Sec. 22-92. Drawings and specifications.

Sobre este texto

  • As published by Municode, retrieved 2026-11-23
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Las notas de arriba, el texto de la sección y su línea de historia se muestran en inglés, tal como los publica la fuente y como los da el corpus.

(a) General requirements. Two or more copies of specifications and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work, shall accompany the application for a permit. Such drawings and specifications shall contain information, in the form of notes or otherwise, as to the quality of materials, where quality is essential to conformity with the technical codes. Such information shall be specific and the technical codes shall not be cited as a whole or in part, nor shall the term "legal" or its equivalent be used as a substitute for specific information. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design.

(b) Authority to require additional data. The building official may require details, computations, stress diagrams and other data necessary to describe the construction or installation and the basis of calculations. All drawings, specifications and accompanying data required by the building official to be prepared by an architect or engineer shall be affixed with their official seal.

(c) Preparation by design professional. The design professional shall be an architect legally registered under the laws of this state regulating the practice of architecture or engineering and shall affix his official seal to the drawings, specifications and accompanying data for the following:

(1) All group occupancies except residential.

(2) Buildings and structures three stories or more high.

For all other buildings and structures, the submittal shall bear the certification of the applicant that some specific state law exception permits its preparation by a person not so registered.

(d) Indication of structural and fire resistance integrity. Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistance wall, floor or partition will be made for electrical, gas, mechanical, plumbing, signal and communication conduits, pipes and systems and also indicate in sufficient detail how the fire integrity will be maintained where required fire resistance floors intersect the exterior walls.

(e) Site drawings. Drawings shall be drawn to scale and shall be of sufficient clarity to indicate the extent of the work proposed and shall show in detail that it will conform to the provisions of this article and all relevant laws, ordinances, rules and regulations. Plans shall include a plot plan drawn to scale showing the location of all easements, drainage facilities, adjacent grades, property lines and proposed buildings and of every existing building on the property. See also section 7.2, titled "Building permit required," in the county zoning resolution, as amended.

(f) Required information for hazardous occupancies. The building official may require the following:

(1) General site plan. A general site plan drawn at a legible scale, which shall include but not be limited to the location of all buildings, exterior storage facilities, permanent accessways, evacuation routes, parking lots, internal roads, chemical loading areas, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment and adjacent property uses. The exterior storage areas shall be identified with the hazard classes and the maximum quantities per hazard class of hazardous materials stored.

(2) Building floor plan. A building floor plan drawn to a legible scale, which shall include but not be limited to all hazardous materials storage facilities within the building and shall indicate rooms, doorways, corridors, exits, fire-rated assemblies with their hourly rating, location of liquidtight rooms, and evacuation routes. Each hazardous materials storage facility shall be identified on the plan with the hazard classes and quantity range per hazard class or the hazardous materials stored.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 11-25-1997(2), att. A, § 3.2)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:barrow-county/code/22-92@2026-11-23-2be54fa91b

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Barrow County Code of Ordinances, Sec. 22-92. Drawings and specifications | Georgia Commons