(a) General discharge prohibitions. No user, person, firm or corporation shall contribute or cause to be contributed directly or indirectly, any pollutant or wastewater which will interfere with the operation or performance of the POTW. These general prohibitions apply to all such users of a POTW whether or not the user is subject to national categorical pretreatment standards or any other national, state or local pretreatment standards or requirements. A user may not contribute the following substances to any county POTW:

(1) Any liquids, solids or gases which by reason of their nature or quantity are, or may be, sufficient either alone or by interaction with other substances to cause fire or explosion or be injurious in any other way to the POTW or to the operation of the POTW. At no time shall a waste stream be discharged with a closed-cup flash point of less than 140°F (60°C) using the test methods specified in 40 CFR section 261.21. At no time shall a waste stream be discharged which yields two successive readings on an explosion hazard meter, at the point of discharge into the system (or at any point in the system), be more than five percent nor any single reading over ten percent of the lower explosive limit (LED) of the meter.

(2) Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through.

(3) Any pollutants which will cause corrosive structural damage to the POTW (in no case with a pH less than 5.5 or higher than 10.5 or wastewater having any other corrosive property capable of causing damage or hazard to structures, equipment and/or personnel of the POTW, unless the POTW is specifically designed to accommodate such wastewater.

(4) Solid or viscous substances in amounts which may cause obstruction to the flow in a sewer or other interference with the operation of the POTW such as, but not limited to, garbage with particles greater than one-half inch in any dimension, ashes, cinders, animal entrails, paunch, manure, offal, bones, hair, hides or fleshings, whole blood, beer or distillery slops, feathers, sand, lime residues, cannery waste, stone or marble dust, metal, grass straw, grass clippings, rags, spent grains, spent hops, waste paper, wood, plastics, paper, cardboard, fiberglass, paint or ink residues, gas, tar, asphalt residues, chemical residues, or residues from refining or processing of wastes.

(5) Any wastewater containing more than 200 ppm of fats, oils, or greases of animal or vegetable origin. Wastewater discharges, which exceed 100 ppm, require a grease trap.

(6) A slug discharge of any pollutant, including oxygen demanding pollutants (BOD, etc.)

released at a flow and/or pollutant concentration, which will cause interference to the POTW. In no case shall a discharge have a flow rate or contain concentration or quantities of pollutants that exceed for any time period longer than 15 minutes, more than five times the average 24-hour concentration, quantities, or flow during normal operation of the discharger's facility.

(7) Any wastewater having a temperature which will inhibit biological activity in the POTW resulting in interference, but in no case wastewater with a temperature that will cause the treatment plant's influent to exceed 40°C (104°F). Unless a higher temperature is allowed in the user's CID permit, no user shall discharge into any sewer line or appurtenance of the POTW wastewater with a temperature exceeding 656

/10 (65.6°C), (150°F).

(8) Any wastewater containing toxic pollutants in sufficient quantity, either singly or by interaction with other pollutants, to injure or interfere with any wastewater treatment process, constitute a hazard to humans or animals, create a toxic effect in the receiving waters of the POTW, or to exceed the limitation set forth in a categorical pretreatment standard. A toxic pollutant shall include, but not be limited to, any pollutant identified pursuant to Section 307(a) of the Act.

(9) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems or are sufficient to create a public nuisance as defined by state law.

(10) Any substance, which may cause the POTW's effluent, or any other product of the POTW such as residues, sludges, or scums, to be unsuitable for reclamation and reuse or to interfere with the reclamation process where the POTW is pursuing a reuse and reclamation program. In no case shall a substance discharged to the POTW be in noncompliance with sludge use or disposal criteria, guidelines, or regulations developed under section 405 of the Act; any criteria, guidelines, or regulations affecting sludge use or disposal developed pursuant to the Solid Waste Disposal Act, the Clean Air Act, the Toxic Substances Control Act, state criteria applicable to the sludge management method being used, or any future federal regulation.

(11) Any substance, which will cause the POTW to violate its NPDES and/or state disposal system permit or the receiving water quality standards.

(12) Any wastewater with objectionable color (greater than 50 color units as described by the standard method defined herein) not removed and discharged into the POTW, such as, but not limited to, dye wastes and spent tanning solutions.

(13) Any liquid or wastewater containing quantities of radioactive waste in excess of presently existing or subsequently accepted limits for drinking water as established by the National Committee on Radiation Protection and Measuring.

(14) Wastewater discharges having contaminant concentrations exceeding upper limits set by the board of commissioners are prohibited, unless the chairman through issuance of a CID permit allows an exception. The current limits apply to the discharge point to the sewer. The limits in micrograms per liter are:

Barrow County Local Pretreatment Limits Pollutant 24-hour Composite Average Maximum (mg/l) Instantaneous Maximum (mg/l) Arsenic (total) 1.00 4.00 Cadmium 0.50 0.60 Copper 3.00 8.00 Chromium (total) 5.00 10.00 Cyanide (total) 2.00 5.00 Hydrogen Sulfide 10.00 20.00 Lead 2.00 4.00 Mercury 0.10 0.20 Nickel 2.50 5.00 Silver 1.00 3.00 Zinc 5.00 10.00 Biochemical oxygen demand

(BOD5)

350.00 700.00 Total suspended solids (TSS) 350.00 700.00 Phosphorus (total) 20.00 50.00 Ammonia 50.00 100.00 pH 5.5 to 10.5 standard units less than 4; greater than 12 Total fats, oils, grease 100.00 200.00

(15) Any waters or wastes containing phenols or other taste or odor producing substances in concentration that exceed limits which may be established by the chairman or as necessary to meet more stringent requirements of state, federal or other agencies of jurisdiction for such discharge to the receiving waters.

(b) Prohibitions on storm drainage and groundwater. Stormwater, groundwater, rain water, street drainage, roof top drainage, basement drainage, subsurface drainage or yard drainage shall not be discharged through direct or indirect connections to a sanitary sewer. Under no conditions will sanitary sewage be discharged to a storm sewer.

(c) National Categorical Pretreatment Standards. The categorical pretreatment standards found in 40 CFR, chapter I, subchapter N, (parts 405—471) are hereby incorporated. Certain industrial users are now or hereafter shall become subject to National Categorical Pretreatment Standards promulgated by the EPA specifying quantities or concentrations of pollutants or pollutant properties, which may be discharged into the POTW. All industrial users subject to a National Categorical Pretreatment Standard shall also comply with any additional or more stringent limitations contained in this section. The provisions of this article shall not be deemed as alleviating, compliance with applicable state and federal regulations. Specific user charge and industrial cost recovery requirements, promulgated pursuant to the Act, shall be considered as a part of this article upon official adoption. All nonresidential users will be required to comply with pretreatment standards as outlined in 40 CFR, part 403. Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in the wastewater, the chairman may impose equivalent concentration or mass limits in accordance with 40 CFR section 403.6(c). When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the chairman shall impose an alternate limit using the combined waste stream formula in 40 CFR section 403.6(c). A user may obtain a variance from a categorical pretreatment standard in accordance with 40 CFR section 403.13 and may obtain a net gross adjustment to a categorical standard in accordance with 40 CFR section 403.15.

(d) State requirements. State requirements and limitations on discharges shall apply in any case where they are more stringent than federal requirements and limitations or those in this article.

(e) Dilution. No user shall ever increase the use of process water or in any way, attempt to dilute a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in the national categorical pretreatment standards, or in any other pollutant specific limitation developed by the county and EPD. The chairman may impose mass limitations on users who are using dilution to meet applicable pretreatment standards or requirements or in other cases when the imposition of mass limitations is appropriate. Where necessary in the opinion of the county, equalizing may be required to bring constituents or volume to an acceptable level and to hold or equalize flows such that no peak flow conditions may interfere with the POTW. Said equalization or holding unit shall have a capacity suitable to serve its intended purpose, as stated above, and be equipped with acceptable outlet control facilities to provide flexibility in operation and accommodate changing conditions in the waste flow.

(f) Accidental or slug discharges.

(1) General. In the case of any discharge, including, but not limited to, accidental discharges, discharges of a nonroutine, episodic nature, a noncustomary batch discharge or a slug load, that may cause potential problems for the POTW, it is the responsibility of the user to immediately telephone and notify the POTW of the incident. The notification shall include:

a. Location of discharge;

b. Type of waste discharged;

c. Concentration and volume; and

d. Corrective actions taken by the user.

(2) Written notice. Within five calendar days following an accidental discharge, the user shall submit to the county a detailed written report describing the cause of the discharge and the measures to be taken by the user to prevent similar future occurrences. Such notification shall not relieve the user of any expense, loss, damage or other liability which may be incurred as a result of damage to the POTW, fish kills, or any other damage to person or property; nor shall such notification relieve the user of any fines, civil penalties, or other liability which may be imposed by this section or other applicable law. Noncompliance with this provision shall constitute a violation of section 90-114 and subject the permittee to the penalties described in that section.

(3) Notice to employees. A notice shall be permanently posted on the user's bulletin board or other prominent place advising employees to call the county sewer emergency phone number in the event of a discharge of any of the substances enumerated in subsection 90-113(a) of this article.

(4) Accidental discharge/slug control plan. At least once every two years, the chairman shall evaluate whether each significant industrial user needs an accidental discharge/ slug control plan. The chairman may require any user to develop, submit for approval, and implement such a plan. Alternatively, the chairman may develop such a plan for any user. An accidental discharge slug control plan shall address, at a minimum, the following:

a. Description of discharge practices, including nonroutine batch discharges;

b. Description of stored chemicals;

c. Procedures for immediately notifying the chairman of any accidental or slug discharge; and

d. Procedures to prevent adverse impact from any accidental or slug discharge.

(5) Hazardous wastes. It is a violation of this article to discharge or cause to discharge any material identified as a hazardous waste by the May 19, 1980 Environmental Protection Agency Hazardous Waste Regulations, part 261 or any revision thereof.

This prohibition extends to all wastes identified in subpart D regardless of the quantity of hazardous material stored or generated.

(6) Discharge to natural outlets, property, or storm drains. The discharge of any wastewater, sewage or polluted waters to any natural outlet or onto any public or private property shall be unlawful. The introduction of sanitary wastewater into a storm sewer system is prohibited.

Historia

La línea de historia que la fuente imprime al final de la sección.

(Ord. of 3-27-2001, § 3)

Leer este código donde se publica (Municode) La fuente es el código del condado tal como lo publica su editorial o su propio sitio web. Consúltelo allí para ver cambios posteriores.

Versión local-code:barrow-county/code/90-113@2026-11-23-97ec35a7d6

El asistente puede decir lo que dice esta sección en esta edición, citándola y enlazándola. No aplicará la ley a su situación, y nada de esto es asesoría legal.

Barrow County Code of Ordinances, Sec. 90-113. Discharge prohibitions | Georgia Commons